|
Records |
Links |
|
Author |
Debora Gil; Aura Hernandez-Sabate; Mireia Brunat;Steven Jansen; Jordi Martinez-Vilalta |
|
|
Title |
Structure-preserving smoothing of biomedical images |
Type |
Journal Article |
|
Year |
2011 |
Publication |
Pattern Recognition |
Abbreviated Journal |
PR |
|
|
Volume |
44 |
Issue |
9 |
Pages |
1842-1851 |
|
|
Keywords |
Non-linear smoothing; Differential geometry; Anatomical structures; segmentation; Cardiac magnetic resonance; Computerized tomography |
|
|
Abstract |
Smoothing of biomedical images should preserve gray-level transitions between adjacent tissues, while restoring contours consistent with anatomical structures. Anisotropic diffusion operators are based on image appearance discontinuities (either local or contextual) and might fail at weak inter-tissue transitions. Meanwhile, the output of block-wise and morphological operations is prone to present a block structure due to the shape and size of the considered pixel neighborhood. In this contribution, we use differential geometry concepts to define a diffusion operator that restricts to image consistent level-sets. In this manner, the final state is a non-uniform intensity image presenting homogeneous inter-tissue transitions along anatomical structures, while smoothing intra-structure texture. Experiments on different types of medical images (magnetic resonance, computerized tomography) illustrate its benefit on a further process (such as segmentation) of images. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0031-3203 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; ADAS |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GHB2011 |
Serial |
1526 |
|
Permanent link to this record |
|
|
|
|
Author |
Aura Hernandez-Sabate; Monica Mitiko; Sergio Shiguemi; Debora Gil |
|
|
Title |
A validation protocol for assessing cardiac phase retrieval in IntraVascular UltraSound |
Type |
Conference Article |
|
Year |
2010 |
Publication |
Computing in Cardiology |
Abbreviated Journal |
|
|
|
Volume |
37 |
Issue |
|
Pages |
899-902 |
|
|
Keywords |
|
|
|
Abstract |
A good reliable approach to cardiac triggering is of utmost importance in obtaining accurate quantitative results of atherosclerotic plaque burden from the analysis of IntraVascular UltraSound. Although, in the last years, there has been an increase in research of methods for retrospective gating, there is no general consensus in a validation protocol. Many methods are based on quality assessment of longitudinal cuts appearance and those reporting quantitative numbers do not follow a standard protocol. Such heterogeneity in validation protocols makes faithful comparison across methods a difficult task. We propose a validation protocol based on the variability of the retrieved cardiac phase and explore the capability of several quality measures for quantifying such variability. An ideal detector, suitable for its application in clinical practice, should produce stable phases. That is, it should always sample the same cardiac cycle fraction. In this context, one should measure the variability (variance) of a candidate sampling with respect a ground truth (reference) sampling, since the variance would indicate how spread we are aiming a target. In order to quantify the deviation between the sampling and the ground truth, we have considered two quality scores reported in the literature: signed distance to the closest reference sample and distance to the right of each reference sample. We have also considered the residuals of the regression line of reference against candidate sampling. The performance of the measures has been explored on a set of synthetic samplings covering different cardiac cycle fractions and variabilities. From our simulations, we conclude that the metrics related to distances are sensitive to the shift considered while the residuals are robust against fraction and variabilities as far as one can establish a pair-wise correspondence between candidate and reference. We will further investigate the impact of false positive and negative detections in experimental data. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
IEEE |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0276-6547 |
ISBN |
978-1-4244-7318-2 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
CINC |
|
|
Notes |
IAM; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ HSM2010 |
Serial |
1551 |
|
Permanent link to this record |
|
|
|
|
Author |
Jaume Garcia; Debora Gil; Luis Badiella; Aura Hernandez-Sabate; Francesc Carreras; Sandra Pujades; Enric Marti |
|
|
Title |
A Normalized Framework for the Design of Feature Spaces Assessing the Left Ventricular Function |
Type |
Journal Article |
|
Year |
2010 |
Publication |
IEEE Transactions on Medical Imaging |
Abbreviated Journal |
TMI |
|
|
Volume |
29 |
Issue |
3 |
Pages |
733-745 |
|
|
Keywords |
|
|
|
Abstract |
A through description of the left ventricle functionality requires combining complementary regional scores. A main limitation is the lack of multiparametric normality models oriented to the assessment of regional wall motion abnormalities (RWMA). This paper covers two main topics involved in RWMA assessment. We propose a general framework allowing the fusion and comparison across subjects of different regional scores. Our framework is used to explore which combination of regional scores (including 2-D motion and strains) is better suited for RWMA detection. Our statistical analysis indicates that for a proper (within interobserver variability) identification of RWMA, models should consider motion and extreme strains. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0278-0062 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GGH2010b |
Serial |
1507 |
|
Permanent link to this record |
|
|
|
|
Author |
Aura Hernandez-Sabate; Debora Gil;Eduard Fernandez-Nofrerias;Petia Radeva; Enric Marti |
|
|
Title |
Approaching Artery Rigid Dynamics in IVUS |
Type |
Journal Article |
|
Year |
2009 |
Publication |
IEEE Transactions on Medical Imaging |
Abbreviated Journal |
TMI |
|
|
Volume |
28 |
Issue |
11 |
Pages |
1670-1680 |
|
|
Keywords |
Fourier analysis; intravascular ultrasound (IVUS) dynamics; longitudinal motion; quality measures; tissue deformation. |
|
|
Abstract |
Tissue biomechanical properties (like strain and stress) are playing an increasing role in diagnosis and long-term treatment of intravascular coronary diseases. Their assessment strongly relies on estimation of vessel wall deformation. Since intravascular ultrasound (IVUS) sequences allow visualizing vessel morphology and reflect its dynamics, this technique represents a useful tool for evaluation of tissue mechanical properties. Image misalignment introduced by vessel-catheter motion is a major artifact for a proper tracking of tissue deformation. In this work, we focus on compensating and assessing IVUS rigid in-plane motion due to heart beating. Motion parameters are computed by considering both the vessel geometry and its appearance in the image. Continuum mechanics laws serve to introduce a novel score measuring motion reduction in in vivo sequences. Synthetic experiments validate the proposed score as measure of motion parameters accuracy; whereas results in in vivo pullbacks show the reliability of the presented methodologies in clinical cases. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0278-0062 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ HGF2009 |
Serial |
1545 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Aura Hernandez-Sabate; Mireia Burnat; Steven Jansen; Jordi Martinez-Vilalta |
|
|
Title |
Structure-Preserving Smoothing of Biomedical Images |
Type |
Conference Article |
|
Year |
2009 |
Publication |
13th International Conference on Computer Analysis of Images and Patterns |
Abbreviated Journal |
|
|
|
Volume |
5702 |
Issue |
|
Pages |
427-434 |
|
|
Keywords |
non-linear smoothing; differential geometry; anatomical structures segmentation; cardiac magnetic resonance; computerized tomography. |
|
|
Abstract |
Smoothing of biomedical images should preserve gray-level transitions between adjacent tissues, while restoring contours consistent with anatomical structures. Anisotropic diffusion operators are based on image appearance discontinuities (either local or contextual) and might fail at weak inter-tissue transitions. Meanwhile, the output of block-wise and morphological operations is prone to present a block structure due to the shape and size of the considered pixel neighborhood. In this contribution, we use differential geometry concepts to define a diffusion operator that restricts to image consistent level-sets. In this manner, the final state is a non-uniform intensity image presenting homogeneous inter-tissue transitions along anatomical structures, while smoothing intra-structure texture. Experiments on different types of medical images (magnetic resonance, computerized tomography) illustrate its benefit on a further process (such as segmentation) of images. |
|
|
Address |
Münster, Germany |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Berlin Heidelberg |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-642-03766-5 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
CAIP |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GHB2009 |
Serial |
1527 |
|
Permanent link to this record |
|
|
|
|
Author |
Patricia Marquez; Debora Gil ; Aura Hernandez-Sabate |
|
|
Title |
Error Analysis for Lucas-Kanade Based Schemes |
Type |
Conference Article |
|
Year |
2012 |
Publication |
9th International Conference on Image Analysis and Recognition |
Abbreviated Journal |
|
|
|
Volume |
7324 |
Issue |
I |
Pages |
184-191 |
|
|
Keywords |
Optical flow, Confidence measure, Lucas-Kanade, Cardiac Magnetic Resonance |
|
|
Abstract |
Optical flow is a valuable tool for motion analysis in medical imaging sequences. A reliable application requires determining the accuracy of the computed optical flow. This is a main challenge given the absence of ground truth in medical sequences. This paper presents an error analysis of Lucas-Kanade schemes in terms of intrinsic design errors and numerical stability of the algorithm. Our analysis provides a confidence measure that is naturally correlated to the accuracy of the flow field. Our experiments show the higher predictive value of our confidence measure compared to existing measures. |
|
|
Address |
Aveiro, Portugal |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer-Verlag Berlin Heidelberg |
Place of Publication |
|
Editor |
|
|
|
Language |
english |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
Campilho, Aurélio and Kamel, Mohamed |
Series Title |
Lecture Notes in Computer Science |
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-642-31294-6 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ICIAR |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ MGH2012a |
Serial |
1899 |
|
Permanent link to this record |
|
|
|
|
Author |
Patricia Marquez; Debora Gil; Aura Hernandez-Sabate; Daniel Kondermann |
|
|
Title |
When Is A Confidence Measure Good Enough? |
Type |
Conference Article |
|
Year |
2013 |
Publication |
9th International Conference on Computer Vision Systems |
Abbreviated Journal |
|
|
|
Volume |
7963 |
Issue |
|
Pages |
344-353 |
|
|
Keywords |
Optical flow, confidence measure, performance evaluation |
|
|
Abstract |
Confidence estimation has recently become a hot topic in image processing and computer vision.Yet, several definitions exist of the term “confidence” which are sometimes used interchangeably. This is a position paper, in which we aim to give an overview on existing definitions,
thereby clarifying the meaning of the used terms to facilitate further research in this field. Based on these clarifications, we develop a theory to compare confidence measures with respect to their quality. |
|
|
Address |
St Petersburg; Russia; July 2013 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Link |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-642-39401-0 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ICVS |
|
|
Notes |
IAM;ADAS; 600.044; 600.057; 600.060; 601.145 |
Approved |
no |
|
|
Call Number |
IAM @ iam @ MGH2013a |
Serial |
2218 |
|
Permanent link to this record |
|
|
|
|
Author |
Patricia Marquez; H. Kause; A. Fuster; Aura Hernandez-Sabate; L. Florack; Debora Gil; Hans van Assen |
|
|
Title |
Factors Affecting Optical Flow Performance in Tagging Magnetic Resonance Imaging |
Type |
Conference Article |
|
Year |
2014 |
Publication |
17th International Conference on Medical Image Computing and Computer Assisted Intervention |
Abbreviated Journal |
|
|
|
Volume |
8896 |
Issue |
|
Pages |
231-238 |
|
|
Keywords |
Optical flow; Performance Evaluation; Synthetic Database; ANOVA; Tagging Magnetic Resonance Imaging |
|
|
Abstract |
Changes in cardiac deformation patterns are correlated with cardiac pathologies. Deformation can be extracted from tagging Magnetic Resonance Imaging (tMRI) using Optical Flow (OF) techniques. For applications of OF in a clinical setting it is important to assess to what extent the performance of a particular OF method is stable across dierent clinical acquisition artifacts. This paper presents a statistical validation framework, based on ANOVA, to assess the motion and appearance factors that have the largest in uence on OF accuracy drop.
In order to validate this framework, we created a database of simulated tMRI data including the most common artifacts of MRI and test three dierent OF methods, including HARP. |
|
|
Address |
Boston; USA; September 2014 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer International Publishing |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-319-14677-5 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
STACOM |
|
|
Notes |
IAM; ADAS; 600.060; 601.145; 600.076; 600.075 |
Approved |
no |
|
|
Call Number |
Admin @ si @ MKF2014 |
Serial |
2495 |
|
Permanent link to this record |
|
|
|
|
Author |
Hanne Kause; Aura Hernandez-Sabate; Patricia Marquez; Andrea Fuster; Luc Florack; Hans van Assen; Debora Gil |
|
|
Title |
Confidence Measures for Assessing the HARP Algorithm in Tagged Magnetic Resonance Imaging |
Type |
Book Chapter |
|
Year |
2015 |
Publication |
Statistical Atlases and Computational Models of the Heart. Revised selected papers of Imaging and Modelling Challenges 6th International Workshop, STACOM 2015, Held in Conjunction with MICCAI 2015 |
Abbreviated Journal |
|
|
|
Volume |
9534 |
Issue |
|
Pages |
69-79 |
|
|
Keywords |
|
|
|
Abstract |
Cardiac deformation and changes therein have been linked to pathologies. Both can be extracted in detail from tagged Magnetic Resonance Imaging (tMRI) using harmonic phase (HARP) images. Although point tracking algorithms have shown to have high accuracies on HARP images, these vary with position. Detecting and discarding areas with unreliable results is crucial for use in clinical support systems. This paper assesses the capability of two confidence measures (CMs), based on energy and image structure, for detecting locations with reduced accuracy in motion tracking results. These CMs were tested on a database of simulated tMRI images containing the most common artifacts that may affect tracking accuracy. CM performance is assessed based on its capability for HARP tracking error bounding and compared in terms of significant differences detected using a multi comparison analysis of variance that takes into account the most influential factors on HARP tracking performance. Results showed that the CM based on image structure was better suited to detect unreliable optical flow vectors. In addition, it was shown that CMs can be used to detect optical flow vectors with large errors in order to improve the optical flow obtained with the HARP tracking algorithm. |
|
|
Address |
Munich; Germany; January 2015 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer International Publishing |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-319-28711-9 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
STACOM |
|
|
Notes |
ADAS; IAM; 600.075; 600.076; 600.060; 601.145 |
Approved |
no |
|
|
Call Number |
Admin @ si @ KHM2015 |
Serial |
2734 |
|
Permanent link to this record |
|
|
|
|
Author |
Aura Hernandez-Sabate; Debora Gil; Jaume Garcia; Enric Marti |
|
|
Title |
Image-based Cardiac Phase Retrieval in Intravascular Ultrasound Sequences |
Type |
Journal Article |
|
Year |
2011 |
Publication |
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control |
Abbreviated Journal |
T-UFFC |
|
|
Volume |
58 |
Issue |
1 |
Pages |
60-72 |
|
|
Keywords |
3-D exploring; ECG; band-pass filter; cardiac motion; cardiac phase retrieval; coronary arteries; electrocardiogram signal; image intensity local mean evolution; image-based cardiac phase retrieval; in vivo pullbacks acquisition; intravascular ultrasound sequences; longitudinal motion; signal extrema; time 36 ms; band-pass filters; biomedical ultrasonics; cardiovascular system; electrocardiography; image motion analysis; image retrieval; image sequences; medical image processing; ultrasonic imaging |
|
|
Abstract |
Longitudinal motion during in vivo pullbacks acquisition of intravascular ultrasound (IVUS) sequences is a major artifact for 3-D exploring of coronary arteries. Most current techniques are based on the electrocardiogram (ECG) signal to obtain a gated pullback without longitudinal motion by using specific hardware or the ECG signal itself. We present an image-based approach for cardiac phase retrieval from coronary IVUS sequences without an ECG signal. A signal reflecting cardiac motion is computed by exploring the image intensity local mean evolution. The signal is filtered by a band-pass filter centered at the main cardiac frequency. Phase is retrieved by computing signal extrema. The average frame processing time using our setup is 36 ms. Comparison to manually sampled sequences encourages a deeper study comparing them to ECG signals. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0885-3010 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;ADAS |
Approved |
no |
|
|
Call Number |
IAM @ iam @ HGG2011 |
Serial |
1546 |
|
Permanent link to this record |