Records |
Links |
|
Author |
Aura Hernandez-Sabate; Debora Gil; David Roche; Monica M. S. Matsumoto; Sergio S. Furuie |
|
|
Title |
Inferring the Performance of Medical Imaging Algorithms |
Type |
Conference Article |
|
Year |
2011 |
Publication |
14th International Conference on Computer Analysis of Images and Patterns |
Abbreviated Journal |
|
|
|
Volume |
6854 |
Issue |
|
Pages |
520-528 |
|
|
Keywords |
Validation, Statistical Inference, Medical Imaging Algorithms. |
|
|
Abstract |
Evaluation of the performance and limitations of medical imaging algorithms is essential to estimate their impact in social, economic or clinical aspects. However, validation of medical imaging techniques is a challenging task due to the variety of imaging and clinical problems involved, as well as, the difficulties for systematically extracting a reliable solely ground truth. Although specific validation protocols are reported in any medical imaging paper, there are still two major concerns: definition of standardized methodologies transversal to all problems and generalization of conclusions to the whole clinical data set.
We claim that both issues would be fully solved if we had a statistical model relating ground truth and the output of computational imaging techniques. Such a statistical model could conclude to what extent the algorithm behaves like the ground truth from the analysis of a sampling of the validation data set. We present a statistical inference framework reporting the agreement and describing the relationship of two quantities. We show its transversality by applying it to validation of two different tasks: contour segmentation and landmark correspondence. |
|
|
Address |
Sevilla |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer-Verlag Berlin Heidelberg |
Place of Publication |
Berlin |
Editor |
Pedro Real; Daniel Diaz-Pernil; Helena Molina-Abril; Ainhoa Berciano; Walter Kropatsch |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
L |
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
CAIP |
|
|
Notes |
IAM; ADAS |
Approved |
no |
|
|
Call Number |
IAM @ iam @ HGR2011 |
Serial |
1676 |
|
Permanent link to this record |
|
|
|
|
Author |
Patricia Marquez; Debora Gil ; Aura Hernandez-Sabate |
|
|
Title |
Error Analysis for Lucas-Kanade Based Schemes |
Type |
Conference Article |
|
Year |
2012 |
Publication |
9th International Conference on Image Analysis and Recognition |
Abbreviated Journal |
|
|
|
Volume |
7324 |
Issue |
I |
Pages |
184-191 |
|
|
Keywords |
Optical flow, Confidence measure, Lucas-Kanade, Cardiac Magnetic Resonance |
|
|
Abstract |
Optical flow is a valuable tool for motion analysis in medical imaging sequences. A reliable application requires determining the accuracy of the computed optical flow. This is a main challenge given the absence of ground truth in medical sequences. This paper presents an error analysis of Lucas-Kanade schemes in terms of intrinsic design errors and numerical stability of the algorithm. Our analysis provides a confidence measure that is naturally correlated to the accuracy of the flow field. Our experiments show the higher predictive value of our confidence measure compared to existing measures. |
|
|
Address |
Aveiro, Portugal |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer-Verlag Berlin Heidelberg |
Place of Publication |
|
Editor |
|
|
|
Language |
english |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
Campilho, Aurélio and Kamel, Mohamed |
Series Title |
Lecture Notes in Computer Science |
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-642-31294-6 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ICIAR |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ MGH2012a |
Serial |
1899 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Agnes Borras; Sergio Vera; Miguel Angel Gonzalez Ballester |
|
|
Title |
A Validation Benchmark for Assessment of Medial Surface Quality for Medical Applications |
Type |
Conference Article |
|
Year |
2013 |
Publication |
9th International Conference on Computer Vision Systems |
Abbreviated Journal |
|
|
|
Volume |
7963 |
Issue |
|
Pages |
334-343 |
|
|
Keywords |
Medial Surfaces; Shape Representation; Medical Applications; Performance Evaluation |
|
|
Abstract |
Confident use of medial surfaces in medical decision support systems requires evaluating their quality for detecting pathological deformations and describing anatomical volumes. Validation in the medical imaging field is a challenging task mainly due to the difficulties for getting consensual ground truth. In this paper we propose a validation benchmark for assessing medial surfaces in the context of medical applications. Our benchmark includes a home-made database of synthetic medial surfaces and volumes and specific scores for evaluating surface accuracy, its stability against volume deformations and its capabilities for accurate reconstruction of anatomical volumes. |
|
|
Address |
Sant Petersburg; Russia; July 2013 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Berlin Heidelberg |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-642-39401-0 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ICVS |
|
|
Notes |
IAM; 600.044; 600.060 |
Approved |
no |
|
|
Call Number |
Admin @ si @ GBV2013 |
Serial |
2300 |
|
Permanent link to this record |
|
|
|
|
Author |
Carles Sanchez; Jorge Bernal; Debora Gil; F. Javier Sanchez |
|
|
Title |
On-line lumen centre detection in gastrointestinal and respiratory endoscopy |
Type |
Conference Article |
|
Year |
2013 |
Publication |
Second International Workshop Clinical Image-Based Procedures |
Abbreviated Journal |
|
|
|
Volume |
8361 |
Issue |
|
Pages |
31-38 |
|
|
Keywords |
Lumen centre detection; Bronchoscopy; Colonoscopy |
|
|
Abstract |
We present in this paper a novel lumen centre detection for gastrointestinal and respiratory endoscopic images. The proposed method is based on the appearance and geometry of the lumen, which we defined as the darkest image region which centre is a hub of image gradients. Experimental results validated on the first public annotated gastro-respiratory database prove the reliability of the method for a wide range of images (with precision over 95 %). |
|
|
Address |
Nagoya; Japan; September 2013 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer International Publishing |
Place of Publication |
|
Editor |
Erdt, Marius and Linguraru, Marius George and Oyarzun Laura, Cristina and Shekhar, Raj and Wesarg, Stefan and González Ballester, Miguel Angel and Drechsler, Klaus |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-3-319-05665-4 |
Medium |
|
|
|
Area |
800 |
Expedition |
|
Conference |
CLIP |
|
|
Notes |
MV; IAM; 600.047; 600.044; 600.060 |
Approved |
no |
|
|
Call Number |
Admin @ si @ SBG2013 |
Serial |
2302 |
|
Permanent link to this record |
|
|
|
|
Author |
Ferran Poveda; Debora Gil;Enric Marti |
|
|
Title |
Multi-resolution DT-MRI cardiac tractography |
Type |
Conference Article |
|
Year |
2012 |
Publication |
Statistical Atlases And Computational Models Of The Heart: Imaging and Modelling Challenges |
Abbreviated Journal |
|
|
|
Volume |
7746 |
Issue |
|
Pages |
270-277 |
|
|
Keywords |
|
|
|
Abstract |
Even using objective measures from DT-MRI no consensus about myocardial architecture has been achieved so far. Streamlining provides good reconstructions at low level of detail, but falls short to give global abstract interpretations. In this paper, we present a multi-resolution methodology that is able to produce simplified representations of cardiac architecture. Our approach produces a reduced set of tracts that are representative of the main geometric features of myocardial anatomical structure. Experiments show that fiber geometry is preserved along reductions, which validates the simplified model for interpretation of cardiac architecture. |
|
|
Address |
Nice, France |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Berlin Heidelberg |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-642-36960-5 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
STACOM |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ PGM2012 |
Serial |
1986 |
|
Permanent link to this record |
|
|
|
|
Author |
Patricia Marquez;Debora Gil;Aura Hernandez-Sabate |
|
|
Title |
A Complete Confidence Framework for Optical Flow |
Type |
Conference Article |
|
Year |
2012 |
Publication |
12th European Conference on Computer Vision – Workshops and Demonstrations |
Abbreviated Journal |
|
|
|
Volume |
7584 |
Issue |
2 |
Pages |
124-133 |
|
|
Keywords |
Optical flow, confidence measures, sparsification plots, error prediction plots |
|
|
Abstract |
Medial representations are powerful tools for describing and parameterizing the volumetric shape of anatomical structures. Existing methods show excellent results when applied to 2D objects, but their quality drops across dimensions. This paper contributes to the computation of medial manifolds in two aspects. First, we provide a standard scheme for the computation of medial manifolds that avoid degenerated medial axis segments; second, we introduce an energy based method which performs independently of the dimension. We evaluate quantitatively the performance of our method with respect to existing approaches, by applying them to synthetic shapes of known medial geometry. Finally, we show results on shape representation of multiple abdominal organs, exploring the use of medial manifolds for the representation of multi-organ relations. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer-Verlag |
Place of Publication |
Florence, Italy, October 7-13, 2012 |
Editor |
Andrea Fusiello, Vittorio Murino ,Rita Cucchiara |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-3-642-33867-0 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ECCVW |
|
|
Notes |
IAM;ADAS; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ MGH2012b |
Serial |
1991 |
|
Permanent link to this record |
|
|
|
|
Author |
Carles Sanchez; Debora Gil; Antoni Rosell; Albert Andaluz; F. Javier Sanchez |
|
|
Title |
Segmentation of Tracheal Rings in Videobronchoscopy combining Geometry and Appearance |
Type |
Conference Article |
|
Year |
2013 |
Publication |
Proceedings of the International Conference on Computer Vision Theory and Applications |
Abbreviated Journal |
|
|
|
Volume |
1 |
Issue |
|
Pages |
153--161 |
|
|
Keywords |
Video-bronchoscopy, tracheal ring segmentation, trachea geometric and appearance model |
|
|
Abstract |
Videobronchoscopy is a medical imaging technique that allows interactive navigation inside the respiratory pathways and minimal invasive interventions. Tracheal procedures are ordinary interventions that require measurement of the percentage of obstructed pathway for injury (stenosis) assessment. Visual assessment of stenosis in videobronchoscopic sequences requires high expertise of trachea anatomy and is prone to human error. Accurate detection of tracheal rings is the basis for automated estimation of the size of stenosed trachea. Processing of videobronchoscopic images acquired at the operating room is a challenging task due to the wide range of artifacts and acquisition conditions. We present a model of the geometric-appearance of tracheal rings for its detection in videobronchoscopic videos. Experiments on sequences acquired at the operating room, show a performance close to inter-observer variability |
|
|
Address |
Barcelona; February 2013 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
SciTePress |
Place of Publication |
Portugal |
Editor |
Sebastiano Battiato and José Braz |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-989-8565-47-1 |
Medium |
|
|
|
Area |
800 |
Expedition |
|
Conference |
VISAPP |
|
|
Notes |
IAM;MV; 600.044; 600.047; 600.060; 605.203 |
Approved |
no |
|
|
Call Number |
IAM @ iam @ SGR2013 |
Serial |
2123 |
|
Permanent link to this record |
|
|
|
|
Author |
Patricia Marquez; Debora Gil; Aura Hernandez-Sabate; Daniel Kondermann |
|
|
Title |
When Is A Confidence Measure Good Enough? |
Type |
Conference Article |
|
Year |
2013 |
Publication |
9th International Conference on Computer Vision Systems |
Abbreviated Journal |
|
|
|
Volume |
7963 |
Issue |
|
Pages |
344-353 |
|
|
Keywords |
Optical flow, confidence measure, performance evaluation |
|
|
Abstract |
Confidence estimation has recently become a hot topic in image processing and computer vision.Yet, several definitions exist of the term “confidence” which are sometimes used interchangeably. This is a position paper, in which we aim to give an overview on existing definitions,
thereby clarifying the meaning of the used terms to facilitate further research in this field. Based on these clarifications, we develop a theory to compare confidence measures with respect to their quality. |
|
|
Address |
St Petersburg; Russia; July 2013 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Link |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-642-39401-0 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ICVS |
|
|
Notes |
IAM;ADAS; 600.044; 600.057; 600.060; 601.145 |
Approved |
no |
|
|
Call Number |
IAM @ iam @ MGH2013a |
Serial |
2218 |
|
Permanent link to this record |
|
|
|
|
Author |
Patricia Marquez; H. Kause; A. Fuster; Aura Hernandez-Sabate; L. Florack; Debora Gil; Hans van Assen |
|
|
Title |
Factors Affecting Optical Flow Performance in Tagging Magnetic Resonance Imaging |
Type |
Conference Article |
|
Year |
2014 |
Publication |
17th International Conference on Medical Image Computing and Computer Assisted Intervention |
Abbreviated Journal |
|
|
|
Volume |
8896 |
Issue |
|
Pages |
231-238 |
|
|
Keywords |
Optical flow; Performance Evaluation; Synthetic Database; ANOVA; Tagging Magnetic Resonance Imaging |
|
|
Abstract |
Changes in cardiac deformation patterns are correlated with cardiac pathologies. Deformation can be extracted from tagging Magnetic Resonance Imaging (tMRI) using Optical Flow (OF) techniques. For applications of OF in a clinical setting it is important to assess to what extent the performance of a particular OF method is stable across dierent clinical acquisition artifacts. This paper presents a statistical validation framework, based on ANOVA, to assess the motion and appearance factors that have the largest in uence on OF accuracy drop.
In order to validate this framework, we created a database of simulated tMRI data including the most common artifacts of MRI and test three dierent OF methods, including HARP. |
|
|
Address |
Boston; USA; September 2014 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer International Publishing |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-319-14677-5 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
STACOM |
|
|
Notes |
IAM; ADAS; 600.060; 601.145; 600.076; 600.075 |
Approved |
no |
|
|
Call Number |
Admin @ si @ MKF2014 |
Serial |
2495 |
|
Permanent link to this record |
|
|
|
|
Author |
Jorge Bernal; Debora Gil; Carles Sanchez; F. Javier Sanchez |
|
|
Title |
Discarding Non Informative Regions for Efficient Colonoscopy Image Analysis |
Type |
Conference Article |
|
Year |
2014 |
Publication |
1st MICCAI Workshop on Computer-Assisted and Robotic Endoscopy |
Abbreviated Journal |
|
|
|
Volume |
8899 |
Issue |
|
Pages |
1-10 |
|
|
Keywords |
Image Segmentation; Polyps, Colonoscopy; Valley Information; Energy Maps |
|
|
Abstract |
In this paper we present a novel polyp region segmentation method for colonoscopy videos. Our method uses valley information associated to polyp boundaries in order to provide an initial segmentation. This first segmentation is refined to eliminate boundary discontinuities caused by image artifacts or other elements of the scene. Experimental results over a publicly annotated database show that our method outperforms both general and specific segmentation methods by providing more accurate regions rich in polyp content. We also prove how image preprocessing is needed to improve final polyp region segmentation. |
|
|
Address |
Boston; USA; September 2014 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer International Publishing |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-319-13409-3 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
CARE |
|
|
Notes |
MV; IAM; 600.044; 600.047; 600.060; 600.075 |
Approved |
no |
|
|
Call Number |
Admin @ si @ BGS2014b |
Serial |
2503 |
|
Permanent link to this record |