Sergio Vera, Debora Gil, Agnes Borras, F. Javier Sanchez, Frederic Perez, Marius G. Linguraru, et al. (2012). "Computation and Evaluation of Medial Surfaces for Shape Representation of Abdominal Organs " In H. Yoshida et al (Ed.), Workshop on Computational and Clinical Applications in Abdominal Imaging (Vol. 7029, 223–230). Lecture Notes in Computer Science. Berlin: Springer Link.
Abstract: Medial representations are powerful tools for describing and parameterizing the volumetric shape of anatomical structures. Existing methods show excellent results when applied to 2D
objects, but their quality drops across dimensions. This paper contributes to the computation of medial manifolds in two aspects. First, we provide a standard scheme for the computation of medial
manifolds that avoid degenerated medial axis segments; second, we introduce an energy based method which performs independently of the dimension. We evaluate quantitatively the performance of our
method with respect to existing approaches, by applying them to synthetic shapes of known medial geometry. Finally, we show results on shape representation of multiple abdominal organs,
exploring the use of medial manifolds for the representation of multi-organ relations.
Keywords: medial manifolds, abdomen.
|
|
|
Hanne Kause, Aura Hernandez-Sabate, Patricia Marquez, Andrea Fuster, Luc Florack, Hans van Assen, et al. (2015). "Confidence Measures for Assessing the HARP Algorithm in Tagged Magnetic Resonance Imaging " In Statistical Atlases and Computational Models of the Heart. Revised selected papers of Imaging and Modelling Challenges 6th International Workshop, STACOM 2015, Held in Conjunction with MICCAI 2015 (Vol. 9534, pp. 69–79). Springer International Publishing.
Abstract: Cardiac deformation and changes therein have been linked to pathologies. Both can be extracted in detail from tagged Magnetic Resonance Imaging (tMRI) using harmonic phase (HARP) images. Although point tracking algorithms have shown to have high accuracies on HARP images, these vary with position. Detecting and discarding areas with unreliable results is crucial for use in clinical support systems. This paper assesses the capability of two confidence measures (CMs), based on energy and image structure, for detecting locations with reduced accuracy in motion tracking results. These CMs were tested on a database of simulated tMRI images containing the most common artifacts that may affect tracking accuracy. CM performance is assessed based on its capability for HARP tracking error bounding and compared in terms of significant differences detected using a multi comparison analysis of variance that takes into account the most influential factors on HARP tracking performance. Results showed that the CM based on image structure was better suited to detect unreliable optical flow vectors. In addition, it was shown that CMs can be used to detect optical flow vectors with large errors in order to improve the optical flow obtained with the HARP tracking algorithm.
|
|
|
Jaume Garcia, Debora Gil, & Aura Hernandez-Sabate. (2010). "Endowing Canonical Geometries to Cardiac Structures " In O. Camara, M. Pop, K. Rhode, M. Sermesant, N. Smith, & A. Young (Eds.), Statistical Atlases And Computational Models Of The Heart (Vol. 6364, pp. 124–133). Lecture Notes in Computer Science. Springer Berlin / Heidelberg.
Abstract: International conference on Cardiac electrophysiological simulation challenge
In this paper, we show that canonical (shape-based) geometries can be endowed to cardiac structures using tubular coordinates defined over their medial axis. We give an analytic formulation of these geometries by means of B-Splines. Since B-Splines present vector space structure PCA can be applied to their control points and statistical models relating boundaries and the interior of the anatomical structures can be derived. We demonstrate the applicability in two cardiac structures, the 3D Left Ventricular volume, and the 2D Left-Right ventricle set in 2D Short Axis view.
|
|
|
H. Martin, Jens Fagertun, Sergio Vera, & Debora Gil. (2017). "Medial structure generation for registration of anatomical structures " In Skeletonization, Theory, Methods and Applications (Vol. 11).
|
|
|
Jaume Garcia, Petia Radeva, & Francesc Carreras. (2004). "Combining Spectral and Active Shape methods to Track Tagged MRI " In Recent Advances in Artificial Intelligence Research and Development (pp. 37–44). IOS Press.
Abstract: Tagged magnetic resonance is a very usefull and unique tool that provides a complete local and global knowledge of the left ventricle (LV) motion. In this article we introduce a method capable of tracking and segmenting the LV. Spectral methods are applied in order to obtain the so called HARP images which encode information about movement and are the base for LV point-tracking. For segmentation we use Active Shapes (ASM) that model LV shape variation in order to overcome possible local misplacements of the boundary. We finally show experiments on both synthetic and real data which appear to be very promising.
Keywords: MR; tagged MR; ASM; LV segmentation; motion estimation.
|
|
|
Debora Gil, & Petia Radeva. (2004). "Inhibition of False Landmarks " In J. V. et al (Ed.), Recent Advances in Artificial Intelligence Research and Development (pp. 233–244). Barcelona (Spain): IOS Press.
Abstract: We argue that a corner detector should be based on the degree of continuity of the tangent vector to the image level sets, work on the image domain and need no assumptions on neither the image local structure nor the particular geometry of the corner/junction. An operator measuring the degree of differentiability of the projection matrix on the image gradient fulfills the above requirements. Its high sensitivity to changes in vector directions makes it suitable for landmark location in real images prone to need smoothing to reduce the impact of noise. Because using smoothing kernels leads to corner misplacement, we suggest an alternative fake response remover based on the receptive field inhibition of spurious details. The combination of both orientation discontinuity detection and noise inhibition produce our Inhibition Orientation Energy (IOE) landmark locator.
|
|
|
Fernando Vilariño, Debora Gil, & Petia Radeva. (2004). "A Novel FLDA Formulation for Numerical Stability Analysis " In P. R. and I. A. J. Vitrià (Ed.), Recent Advances in Artificial Intelligence Research and Development (Vol. 113, pp. 77–84). IOS Press.
Abstract: Fisher Linear Discriminant Analysis (FLDA) is one of the most popular techniques used in classification applying dimensional reduction. The numerical scheme involves the inversion of the within-class scatter matrix, which makes FLDA potentially ill-conditioned when it becomes singular. In this paper we present a novel explicit formulation of FLDA in terms of the eccentricity ratio and eigenvector orientations of the within-class scatter matrix. An analysis of this function will characterize those situations where FLDA response is not reliable because of numerical instability. This can solve common situations of poor classification performance in computer vision.
Keywords: Supervised Learning; Linear Discriminant Analysis; Numerical Stability; Computer Vision
|
|
|
Debora Gil, Jordi Gonzalez, & Gemma Sanchez (Eds.). (2007)." Computer Vision: Advances in Research and Development" . 2. Bellaterra (Spain): UAB.
|
|
|
Jaume Garcia. (2009). "Statistical Models of the Architecture and Function of the Left Ventricle " (Debora Gil, Ed.). Ph.D. thesis, Ediciones Graficas Rey, .
Abstract: Cardiovascular Diseases, specially those affecting the Left Ventricle (LV), are the leading cause of death in developed countries with approximately a 30% of all global deaths. In order to address this public health concern, physicians focus on diagnosis and therapy planning. On one hand, early and accurate detection of Regional Wall Motion Abnormalities (RWMA) significantly contributes to a quick diagnosis and prevents the patient to reach more severe stages. On the other hand, a thouroughly knowledge of the normal gross anatomy of the LV, as well as, the distribution of its muscular fibers is crucial for designing specific interventions and therapies (such as pacemaker implanction). Statistical models obtained from the analysis of different imaging modalities allow the computation of the normal ranges of variation within a given population. Normality models are a valuable tool for the definition of objective criterions quantifying the degree of (anomalous) deviation of the LV function and anatomy for a given subject. The creation of statistical models involve addressing three main issues: extraction of data from images, definition of a common domain for comparison of data across patients and designing appropriate statistical analysis schemes. In this PhD thesis we present generic image processing tools for the creation of statistical models of the LV anatomy and function. On one hand, we use differential geometry concepts to define a computational framework (the Normalized Parametric Domain, NPD) suitable for the comparison and fusion of several clinical scores obtained over the LV. On the other hand, we present a variational approach (the Harmonic Phase Flow, HPF) for the estimation of myocardial motion that provides dense and continuous vector fields without overestimating motion at injured areas. These tools are used for the creation of statistical models. Regarding anatomy, we obtain an atlas jointly modelling, both, LV gross anatomy and fiber architecture. Regarding function, we compute normality patterns of scores characterizing the (global and local) LV function and explore, for the first time, the configuration of local scores better suited for RWMA detection.
|
|
|
Debora Gil. (2004). "Geometric Differential Operators for Shape Modelling " (Jordi Saludes i Closa, & Petia Radeva, Eds.). Ph.D. thesis, Ediciones Graficas Rey, Barcelona (Spain).
Abstract: Medical imaging feeds research in many computer vision and image processing fields: image filtering, segmentation, shape recovery, registration, retrieval and pattern matching. Because of their low contrast changes and large variety of artifacts and noise, medical imaging processing techniques relying on an analysis of the geometry of image level sets rather than on intensity values result in more robust treatment. From the starting point of treatment of intravascular images, this PhD thesis ad- dresses the design of differential image operators based on geometric principles for a robust shape modelling and restoration. Among all fields applying shape recovery, we approach filtering and segmentation of image objects. For a successful use in real images, the segmentation process should go through three stages: noise removing, shape modelling and shape recovery. This PhD addresses all three topics, but for the sake of algorithms as automated as possible, techniques for image processing will be designed to satisfy three main principles: a) convergence of the iterative schemes to non-trivial states avoiding image degeneration to a constant image and representing smooth models of the originals; b) smooth asymptotic behav- ior ensuring stabilization of the iterative process; c) fixed parameter values ensuring equal (domain free) performance of the algorithms whatever initial images/shapes. Our geometric approach to the generic equations that model the different processes approached enables defining techniques satisfying all the former requirements. First, we introduce a new curvature-based geometric flow for image filtering achieving a good compromise between noise removing and resemblance to original images. Sec- ond, we describe a new family of diffusion operators that restrict their scope to image level curves and serve to restore smooth closed models from unconnected sets of points. Finally, we design a regularization of snake (distance) maps that ensures its smooth convergence towards any closed shape. Experiments show that performance of the techniques proposed overpasses that of state-of-the-art algorithms.
|
|