|
Records |
Links |
|
Author |
Patricia Marquez; H. Kause; A. Fuster; Aura Hernandez-Sabate; L. Florack; Debora Gil; Hans van Assen |
|
|
Title |
Factors Affecting Optical Flow Performance in Tagging Magnetic Resonance Imaging |
Type |
Conference Article |
|
Year |
2014 |
Publication |
17th International Conference on Medical Image Computing and Computer Assisted Intervention |
Abbreviated Journal |
|
|
|
Volume |
8896 |
Issue |
|
Pages |
231-238 |
|
|
Keywords |
Optical flow; Performance Evaluation; Synthetic Database; ANOVA; Tagging Magnetic Resonance Imaging |
|
|
Abstract |
Changes in cardiac deformation patterns are correlated with cardiac pathologies. Deformation can be extracted from tagging Magnetic Resonance Imaging (tMRI) using Optical Flow (OF) techniques. For applications of OF in a clinical setting it is important to assess to what extent the performance of a particular OF method is stable across dierent clinical acquisition artifacts. This paper presents a statistical validation framework, based on ANOVA, to assess the motion and appearance factors that have the largest in uence on OF accuracy drop.
In order to validate this framework, we created a database of simulated tMRI data including the most common artifacts of MRI and test three dierent OF methods, including HARP. |
|
|
Address |
Boston; USA; September 2014 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer International Publishing |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-319-14677-5 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
STACOM |
|
|
Notes |
IAM; ADAS; 600.060; 601.145; 600.076; 600.075 |
Approved |
no |
|
|
Call Number |
Admin @ si @ MKF2014 |
Serial |
2495 |
|
Permanent link to this record |
|
|
|
|
Author |
Francesco Brughi; Debora Gil; Llorenç Badiella; Eva Jove Casabella; Oriol Ramos Terrades |
|
|
Title |
Exploring the impact of inter-query variability on the performance of retrieval systems |
Type |
Conference Article |
|
Year |
2014 |
Publication |
11th International Conference on Image Analysis and Recognition |
Abbreviated Journal |
|
|
|
Volume |
8814 |
Issue |
|
Pages |
413–420 |
|
|
Keywords |
|
|
|
Abstract |
This paper introduces a framework for evaluating the performance of information retrieval systems. Current evaluation metrics provide an average score that does not consider performance variability across the query set. In this manner, conclusions lack of any statistical significance, yielding poor inference to cases outside the query set and possibly unfair comparisons. We propose to apply statistical methods in order to obtain a more informative measure for problems in which different query classes can be identified. In this context, we assess the performance variability on two levels: overall variability across the whole query set and specific query class-related variability. To this end, we estimate confidence bands for precision-recall curves, and we apply ANOVA in order to assess the significance of the performance across different query classes. |
|
|
Address |
Algarve; Portugal; October 2014 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer International Publishing |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-319-11757-7 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ICIAR |
|
|
Notes |
IAM; DAG; 600.060; 600.061; 600.077; 600.075 |
Approved |
no |
|
|
Call Number |
Admin @ si @ BGB2014 |
Serial |
2559 |
|
Permanent link to this record |
|
|
|
|
Author |
Carles Sanchez; Jorge Bernal; Debora Gil; F. Javier Sanchez |
|
|
Title |
On-line lumen centre detection in gastrointestinal and respiratory endoscopy |
Type |
Conference Article |
|
Year |
2013 |
Publication |
Second International Workshop Clinical Image-Based Procedures |
Abbreviated Journal |
|
|
|
Volume |
8361 |
Issue |
|
Pages |
31-38 |
|
|
Keywords |
Lumen centre detection; Bronchoscopy; Colonoscopy |
|
|
Abstract |
We present in this paper a novel lumen centre detection for gastrointestinal and respiratory endoscopic images. The proposed method is based on the appearance and geometry of the lumen, which we defined as the darkest image region which centre is a hub of image gradients. Experimental results validated on the first public annotated gastro-respiratory database prove the reliability of the method for a wide range of images (with precision over 95 %). |
|
|
Address |
Nagoya; Japan; September 2013 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer International Publishing |
Place of Publication |
|
Editor |
Erdt, Marius and Linguraru, Marius George and Oyarzun Laura, Cristina and Shekhar, Raj and Wesarg, Stefan and González Ballester, Miguel Angel and Drechsler, Klaus |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-3-319-05665-4 |
Medium |
|
|
|
Area |
800 |
Expedition |
|
Conference |
CLIP |
|
|
Notes |
MV; IAM; 600.047; 600.044; 600.060 |
Approved |
no |
|
|
Call Number |
Admin @ si @ SBG2013 |
Serial |
2302 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Agnes Borras; Sergio Vera; Miguel Angel Gonzalez Ballester |
|
|
Title |
A Validation Benchmark for Assessment of Medial Surface Quality for Medical Applications |
Type |
Conference Article |
|
Year |
2013 |
Publication |
9th International Conference on Computer Vision Systems |
Abbreviated Journal |
|
|
|
Volume |
7963 |
Issue |
|
Pages |
334-343 |
|
|
Keywords |
Medial Surfaces; Shape Representation; Medical Applications; Performance Evaluation |
|
|
Abstract |
Confident use of medial surfaces in medical decision support systems requires evaluating their quality for detecting pathological deformations and describing anatomical volumes. Validation in the medical imaging field is a challenging task mainly due to the difficulties for getting consensual ground truth. In this paper we propose a validation benchmark for assessing medial surfaces in the context of medical applications. Our benchmark includes a home-made database of synthetic medial surfaces and volumes and specific scores for evaluating surface accuracy, its stability against volume deformations and its capabilities for accurate reconstruction of anatomical volumes. |
|
|
Address |
Sant Petersburg; Russia; July 2013 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Berlin Heidelberg |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-642-39401-0 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ICVS |
|
|
Notes |
IAM; 600.044; 600.060 |
Approved |
no |
|
|
Call Number |
Admin @ si @ GBV2013 |
Serial |
2300 |
|
Permanent link to this record |
|
|
|
|
Author |
Patricia Marquez; Debora Gil; Aura Hernandez-Sabate; Daniel Kondermann |
|
|
Title |
When Is A Confidence Measure Good Enough? |
Type |
Conference Article |
|
Year |
2013 |
Publication |
9th International Conference on Computer Vision Systems |
Abbreviated Journal |
|
|
|
Volume |
7963 |
Issue |
|
Pages |
344-353 |
|
|
Keywords |
Optical flow, confidence measure, performance evaluation |
|
|
Abstract |
Confidence estimation has recently become a hot topic in image processing and computer vision.Yet, several definitions exist of the term “confidence” which are sometimes used interchangeably. This is a position paper, in which we aim to give an overview on existing definitions,
thereby clarifying the meaning of the used terms to facilitate further research in this field. Based on these clarifications, we develop a theory to compare confidence measures with respect to their quality. |
|
|
Address |
St Petersburg; Russia; July 2013 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Link |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-642-39401-0 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ICVS |
|
|
Notes |
IAM;ADAS; 600.044; 600.057; 600.060; 601.145 |
Approved |
no |
|
|
Call Number |
IAM @ iam @ MGH2013a |
Serial |
2218 |
|
Permanent link to this record |
|
|
|
|
Author |
Ferran Poveda; Debora Gil;Enric Marti |
|
|
Title |
Multi-resolution DT-MRI cardiac tractography |
Type |
Conference Article |
|
Year |
2012 |
Publication |
Statistical Atlases And Computational Models Of The Heart: Imaging and Modelling Challenges |
Abbreviated Journal |
|
|
|
Volume |
7746 |
Issue |
|
Pages |
270-277 |
|
|
Keywords |
|
|
|
Abstract |
Even using objective measures from DT-MRI no consensus about myocardial architecture has been achieved so far. Streamlining provides good reconstructions at low level of detail, but falls short to give global abstract interpretations. In this paper, we present a multi-resolution methodology that is able to produce simplified representations of cardiac architecture. Our approach produces a reduced set of tracts that are representative of the main geometric features of myocardial anatomical structure. Experiments show that fiber geometry is preserved along reductions, which validates the simplified model for interpretation of cardiac architecture. |
|
|
Address |
Nice, France |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Berlin Heidelberg |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-642-36960-5 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
STACOM |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ PGM2012 |
Serial |
1986 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil;Agnes Borras;Ruth Aris;Mariano Vazquez;Pierre Lafortune; Guillame Houzeaux |
|
|
Title |
What a difference in biomechanics cardiac fiber makes |
Type |
Conference Article |
|
Year |
2012 |
Publication |
Statistical Atlases And Computational Models Of The Heart: Imaging and Modelling Challenges |
Abbreviated Journal |
|
|
|
Volume |
7746 |
Issue |
|
Pages |
253-260 |
|
|
Keywords |
|
|
|
Abstract |
Computational simulations of the heart are a powerful tool for a comprehensive understanding of cardiac function and its intrinsic relationship with its muscular architecture. Cardiac biomechanical models require a vector field representing the orientation of cardiac fibers. A wrong orientation of the fibers can lead to a
non-realistic simulation of the heart functionality. In this paper we explore the impact of the fiber information on the simulated biomechanics of cardiac muscular anatomy. We have used the John Hopkins database to perform a biomechanical simulation using both a synthetic benchmark fiber distribution and the data obtained experimentally from DTI. Results illustrate how differences in fiber orientation affect heart deformation along cardiac cycle. |
|
|
Address |
Nice, France |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Berlin Heidelberg |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-642-36960-5 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
STACOM |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GBA2012 |
Serial |
1987 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Jaume Garcia; Aura Hernandez-Sabate; Enric Marti |
|
|
Title |
Manifold parametrization of the left ventricle for a statistical modelling of its complete anatomy |
Type |
Conference Article |
|
Year |
2010 |
Publication |
8th Medical Imaging |
Abbreviated Journal |
|
|
|
Volume |
7623 |
Issue |
762304 |
Pages |
304 |
|
|
Keywords |
|
|
|
Abstract |
Distortion of Left Ventricle (LV) external anatomy is related to some dysfunctions, such as hypertrophy. The architecture of myocardial fibers determines LV electromechanical activation patterns as well as mechanics. Thus, their joined modelling would allow the design of specific interventions (such as peacemaker implantation and LV remodelling) and therapies (such as resynchronization). On one hand, accurate modelling of external anatomy requires either a dense sampling or a continuous infinite dimensional approach, which requires non-Euclidean statistics. On the other hand, computation of fiber models requires statistics on Riemannian spaces. Most approaches compute separate statistical models for external anatomy and fibers architecture. In this work we propose a general mathematical framework based on differential geometry concepts for computing a statistical model including, both, external and fiber anatomy. Our framework provides a continuous approach to external anatomy supporting standard statistics. We also provide a straightforward formula for the computation of the Riemannian fiber statistics. We have applied our methodology to the computation of complete anatomical atlas of canine hearts from diffusion tensor studies. The orientation of fibers over the average external geometry agrees with the segmental description of orientations reported in the literature. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
SPIE |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
SPIE |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GGH2010a |
Serial |
1522 |
|
Permanent link to this record |
|
|
|
|
Author |
Patricia Marquez;Debora Gil;Aura Hernandez-Sabate |
|
|
Title |
A Complete Confidence Framework for Optical Flow |
Type |
Conference Article |
|
Year |
2012 |
Publication |
12th European Conference on Computer Vision – Workshops and Demonstrations |
Abbreviated Journal |
|
|
|
Volume |
7584 |
Issue |
2 |
Pages |
124-133 |
|
|
Keywords |
Optical flow, confidence measures, sparsification plots, error prediction plots |
|
|
Abstract |
Medial representations are powerful tools for describing and parameterizing the volumetric shape of anatomical structures. Existing methods show excellent results when applied to 2D objects, but their quality drops across dimensions. This paper contributes to the computation of medial manifolds in two aspects. First, we provide a standard scheme for the computation of medial manifolds that avoid degenerated medial axis segments; second, we introduce an energy based method which performs independently of the dimension. We evaluate quantitatively the performance of our method with respect to existing approaches, by applying them to synthetic shapes of known medial geometry. Finally, we show results on shape representation of multiple abdominal organs, exploring the use of medial manifolds for the representation of multi-organ relations. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer-Verlag |
Place of Publication |
Florence, Italy, October 7-13, 2012 |
Editor |
Andrea Fusiello, Vittorio Murino ,Rita Cucchiara |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-3-642-33867-0 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ECCVW |
|
|
Notes |
IAM;ADAS; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ MGH2012b |
Serial |
1991 |
|
Permanent link to this record |
|
|
|
|
Author |
Patricia Marquez; Debora Gil ; Aura Hernandez-Sabate |
|
|
Title |
Error Analysis for Lucas-Kanade Based Schemes |
Type |
Conference Article |
|
Year |
2012 |
Publication |
9th International Conference on Image Analysis and Recognition |
Abbreviated Journal |
|
|
|
Volume |
7324 |
Issue |
I |
Pages |
184-191 |
|
|
Keywords |
Optical flow, Confidence measure, Lucas-Kanade, Cardiac Magnetic Resonance |
|
|
Abstract |
Optical flow is a valuable tool for motion analysis in medical imaging sequences. A reliable application requires determining the accuracy of the computed optical flow. This is a main challenge given the absence of ground truth in medical sequences. This paper presents an error analysis of Lucas-Kanade schemes in terms of intrinsic design errors and numerical stability of the algorithm. Our analysis provides a confidence measure that is naturally correlated to the accuracy of the flow field. Our experiments show the higher predictive value of our confidence measure compared to existing measures. |
|
|
Address |
Aveiro, Portugal |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer-Verlag Berlin Heidelberg |
Place of Publication |
|
Editor |
|
|
|
Language |
english |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
Campilho, Aurélio and Kamel, Mohamed |
Series Title |
Lecture Notes in Computer Science |
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-642-31294-6 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ICIAR |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ MGH2012a |
Serial |
1899 |
|
Permanent link to this record |