|
Debora Gil, & Petia Radeva. (2006). "Inhibition of false landmarks " . Pattern Recognition Letters, 27(9), 1022–1030.
Abstract: Corners and junctions are landmarks characterized by the lack of differentiability in the unit tangent to the image level curve. Detectors based on differential operators are not, by their own definition, the best posed as they require a higher degree of differentiability to yield a reliable response. We argue that a corner detector should be based on the degree of continuity of the tangent vector to the image level sets, work on the image domain and need no assumptions on neither the image local structure nor the particular geometry of the corner/junction. An operator measuring the degree of differentiability of the projection matrix on the image gradient fulfills the above requirements. Because using smoothing kernels leads to corner misplacement, we suggest an alternative fake response remover based on the receptive field inhibition of spurious details. The combination of both orientation discontinuity detection and noise inhibition produce our inhibition orientation energy (IOE) landmark locator.
|
|
|
H. Martin Kjer, Jens Fagertun, Sergio Vera, Debora Gil, Miguel Angel Gonzalez Ballester, & Rasmus R. Paulsena. (2016). "Free-form image registration of human cochlear uCT data using skeleton similarity as anatomical prior " . Patter Recognition Letters, 76(1), 76–82.
|
|
|
Debora Gil, Aura Hernandez-Sabate, Mireia Brunat, Steven Jansen, & Jordi Martinez-Vilalta. (2011). "Structure-preserving smoothing of biomedical images " . Pattern Recognition, 44(9), 1842–1851.
Abstract: Smoothing of biomedical images should preserve gray-level transitions between adjacent tissues, while restoring contours consistent with anatomical structures. Anisotropic diffusion operators are based on image appearance discontinuities (either local or contextual) and might fail at weak inter-tissue transitions. Meanwhile, the output of block-wise and morphological operations is prone to present a block structure due to the shape and size of the considered pixel neighborhood. In this contribution, we use differential geometry concepts to define a diffusion operator that restricts to image consistent level-sets. In this manner, the final state is a non-uniform intensity image presenting homogeneous inter-tissue transitions along anatomical structures, while smoothing intra-structure texture. Experiments on different types of medical images (magnetic resonance, computerized tomography) illustrate its benefit on a further process (such as segmentation) of images.
Keywords: Non-linear smoothing; Differential geometry; Anatomical structures; segmentation; Cardiac magnetic resonance; Computerized tomography
|
|
|
Debora Gil, Carles Sanchez, Agnes Borras, Marta Diez-Ferrer, & Antoni Rosell. (2019). "Segmentation of Distal Airways using Structural Analysis " . PloS one, 14(12).
Abstract: Segmentation of airways in Computed Tomography (CT) scans is a must for accurate support of diagnosis and intervention of many pulmonary disorders. In particular, lung cancer diagnosis would benefit from segmentations reaching most distal airways. We present a method that combines descriptors of bronchi local appearance and graph global structural analysis to fine-tune thresholds on the descriptors adapted for each bronchial level. We have compared our method to the top performers of the EXACT09 challenge and to a commercial software for biopsy planning evaluated in an own-collected data-base of high resolution CT scans acquired under different breathing conditions. Results on EXACT09 data show that our method provides a high leakage reduction with minimum loss in airway detection. Results on our data-base show the reliability across varying breathing conditions and a competitive performance for biopsy planning compared to a commercial solution.
|
|
|
Sergio Vera, Debora Gil, Agnes Borras, Marius George Linguraru, & Miguel Angel Gonzalez Ballester. (2013). "Geometric Steerable Medial Maps " . Machine Vision and Applications, 24(6), 1255–1266.
Abstract: In order to provide more intuitive and easily interpretable representations of complex shapes/organs, medial manifolds should reach a compromise between simplicity in geometry and capability for restoring the anatomy/shape of the organ/volume. Existing morphological methods show excellent results when applied to 2D objects, but their quality drops across dimensions.
This paper contributes to the computation of medial manifolds in two aspects. First, we provide a standard scheme for the computation of medial manifolds that avoids degenerated medial axis segments. Second, we introduce a continuous operator for accurate and efficient computation of medial structures of arbitrary dimension. We evaluate quantitatively the performance of our method with respect to existing approaches, by applying them to syn- thetic shapes of known medial geometry. We also show its higher performance for medical imaging applications in terms of simplicity of medial structures and capability for reconstructing the anatomical volume.
Keywords: Medial Representations ,Medial Manifolds Comparation , Surface , Reconstruction
|
|
|
Misael Rosales, Petia Radeva, Oriol Rodriguez-Leor, & Debora Gil. (2009). "Modelling of image-catheter motion for 3-D IVUS " . Medical image analysis, 13(1), 91–104.
Abstract: Three-dimensional intravascular ultrasound (IVUS) allows to visualize and obtain volumetric measurements of coronary lesions through an exploration of the cross sections and longitudinal views of arteries. However, the visualization and subsequent morpho-geometric measurements in IVUS longitudinal cuts are subject to distortion caused by periodic image/vessel motion around the IVUS catheter. Usually, to overcome the image motion artifact ECG-gating and image-gated approaches are proposed, leading to slowing the pullback acquisition or disregarding part of IVUS data. In this paper, we argue that the image motion is due to 3-D vessel geometry as well as cardiac dynamics, and propose a dynamic model based on the tracking of an elliptical vessel approximation to recover the rigid transformation and align IVUS images without loosing any IVUS data. We report an extensive validation with synthetic simulated data and in vivo IVUS sequences of 30 patients achieving an average reduction of the image artifact of 97% in synthetic data and 79% in real-data. Our study shows that IVUS alignment improves longitudinal analysis of the IVUS data and is a necessary step towards accurate reconstruction and volumetric measurements of 3-D IVUS.
Keywords: Intravascular ultrasound (IVUS); Motion estimation; Motion decomposition; Fourier
|
|
|
Debora Gil, Sergio Vera, Agnes Borras, Albert Andaluz, & Miguel Angel Gonzalez Ballester. (2017). "Anatomical Medial Surfaces with Efficient Resolution of Branches Singularities " . Medical Image Analysis, 35, 390–402.
Abstract: Medial surfaces are powerful tools for shape description, but their use has been limited due to the sensibility existing methods to branching artifacts. Medial branching artifacts are associated to perturbations of the object boundary rather than to geometric features. Such instability is a main obstacle for a condent application in shape recognition and description. Medial branches correspond to singularities of the medial surface and, thus, they are problematic for existing morphological and energy-based algorithms. In this paper, we use algebraic geometry concepts in an energy-based approach to compute a medial surface presenting a stable branching topology. We also present an ecient GPU-CPU implementation using standard image processing tools. We show the method computational eciency and quality on a custom made synthetic database. Finally, we present some results on a medical imaging application for localization of abdominal pathologies.
Keywords: Medial Representations; Shape Recognition; Medial Branching Stability ; Singular Points
|
|
|
Debora Gil, & Petia Radeva. (2003). "Curvature Vector Flow to Assure Convergent Deformable Models for Shape Modelling " In B. Springer (Ed.), Energy Minimization Methods In Computer Vision And Pattern Recognition (Vol. 2683, pp. 357–372). Lecture Notes in Computer Science. Lisbon, PORTUGAL: Springer, Berlin.
Abstract: Poor convergence to concave shapes is a main limitation of snakes as a standard segmentation and shape modelling technique. The gradient of the external energy of the snake represents a force that pushes the snake into concave regions, as its internal energy increases when new inexion points are created. In spite of the improvement of the external energy by the gradient vector ow technique, highly non convex shapes can not be obtained, yet. In the present paper, we develop a new external energy based on the geometry of the curve to be modelled. By tracking back the deformation of a curve that evolves by minimum curvature ow, we construct a distance map that encapsulates the natural way of adapting to non convex shapes. The gradient of this map, which we call curvature vector ow (CVF), is capable of attracting a snake towards any contour, whatever its geometry. Our experiments show that, any initial snake condition converges to the curve to be modelled in optimal time.
Keywords: Initial condition; Convex shape; Non convex analysis; Increase; Segmentation; Gradient; Standard; Standards; Concave shape; Flow models; Tracking; Edge detection; Curvature
|
|
|
Debora Gil, Oriol Rodriguez-Leor, Petia Radeva, & Aura Hernandez-Sabate. (2007). "Assessing Artery Motion Compensation in IVUS " In Computer Analysis Of Images And Patterns (Vol. 4673, pp. 213–220). Lecture Notes in Computer Science. Heidelberg: Springerlink.
Abstract: Cardiac dynamics suppression is a main issue for visual improvement and computation of tissue mechanical properties in IntraVascular UltraSound (IVUS). Although in recent times several motion compensation techniques have arisen, there is a lack of objective evaluation of motion reduction in in vivo pullbacks. We consider that the assessment protocol deserves special attention for the sake of a clinical applicability as reliable as possible. Our work focuses on defining a quality measure and a validation protocol assessing IVUS motion compensation. On the grounds of continuum mechanics laws we introduce a novel score measuring motion reduction in in vivo sequences. Synthetic experiments validate the proposed score as measure of motion parameters accuracy; while results in in vivo pullbacks show its reliability in clinical cases.
Keywords: validation standards; quality measures; IVUS motion compensation; conservation laws; Fourier development
|
|
|
Misael Rosales, Petia Radeva, Oriol Rodriguez, & Debora Gil. (2005). "Suppression of IVUS Image Rotation. A Kinematic Approach " In Monica Andres and Hernandez Petia and Santos A. and R. Frangi (Ed.), Functional Imaging and Modeling of the Heart (Vol. 3504, pp. 889–892). Lecture Notes in Computer Science, 3504. Springer Berlin / Heidelberg.
Abstract: IntraVascular Ultrasound (IVUS) is an exploratory technique used in interventional procedures that shows cross section images of arteries and provides qualitative information about the causes and severity of the arterial lumen narrowing. Cross section analysis as well as visualization of plaque extension in a vessel segment during the catheter imaging pullback are the technique main advantages. However, IVUS sequence exhibits a periodic rotation artifact that makes difficult the longitudinal lesion inspection and hinders any segmentation algorithm. In this paper we propose a new kinematic method to estimate and remove the image rotation of IVUS images sequences. Results on several IVUS sequences show good results and prompt some of the clinical applications to vessel dynamics study, and relation to vessel pathology.
|
|