|
Patricia Suarez, Angel Sappa and Boris X. Vintimilla. 2017. Infrared Image Colorization based on a Triplet DCGAN Architecture. IEEE Conference on Computer Vision and Pattern Recognition Workshops.
Abstract: This paper proposes a novel approach for colorizing near infrared (NIR) images using Deep Convolutional Generative Adversarial Network (GAN) architectures. The proposed approach is based on the usage of a triplet model for learning each color channel independently, in a more homogeneous way. It allows a fast convergence during the training, obtaining a greater similarity between the given NIR image and the corresponding ground truth. The proposed approach has been evaluated with a large data set of NIR images and compared with a recent approach, which is also based on a GAN architecture but in this case all the
color channels are obtained at the same time.
|
|
|
Patricia Suarez, Angel Sappa and Boris X. Vintimilla. 2017. Colorizing Infrared Images through a Triplet Conditional DCGAN Architecture. 19th international conference on image analysis and processing.
Abstract: This paper focuses on near infrared (NIR) image colorization by using a Conditional Deep Convolutional Generative Adversarial Network (CDCGAN) architecture model. The proposed architecture is based on the usage of a conditional probabilistic generative model. Firstly, it learns to colorize the given input image, by using a triplet model architecture that tackle every channel in an independent way. In the proposed model, the nal layer of red channel consider the infrared image to enhance the details, resulting in a sharp RGB image. Then, in the second stage, a discriminative model is used to estimate the probability that the generated image came from the training dataset, rather than the image automatically generated. Experimental results with a large set of real images are provided showing the validity of the proposed approach. Additionally, the proposed approach is compared with a state of the art approach showing better results.
Keywords: CNN in Multispectral Imaging; Image Colorization
|
|
|
Patricia Marquez, Debora Gil and Aura Hernandez-Sabate. 2012. A Complete Confidence Framework for Optical Flow. In Andrea Fusiello, V.M., Rita Cucchiara, ed. 12th European Conference on Computer Vision – Workshops and Demonstrations. Florence, Italy, October 7-13, 2012, Springer-Verlag, 124–133. (LNCS.)
Abstract: Medial representations are powerful tools for describing and parameterizing the volumetric shape of anatomical structures. Existing methods show excellent results when applied to 2D objects, but their quality drops across dimensions. This paper contributes to the computation of medial manifolds in two aspects. First, we provide a standard scheme for the computation of medial manifolds that avoid degenerated medial axis segments; second, we introduce an energy based method which performs independently of the dimension. We evaluate quantitatively the performance of our method with respect to existing approaches, by applying them to synthetic shapes of known medial geometry. Finally, we show results on shape representation of multiple abdominal organs, exploring the use of medial manifolds for the representation of multi-organ relations.
Keywords: Optical flow, confidence measures, sparsification plots, error prediction plots
|
|
|
Patricia Marquez and 6 others. 2014. Factors Affecting Optical Flow Performance in Tagging Magnetic Resonance Imaging. 17th International Conference on Medical Image Computing and Computer Assisted Intervention. Springer International Publishing, 231–238. (LNCS.)
Abstract: Changes in cardiac deformation patterns are correlated with cardiac pathologies. Deformation can be extracted from tagging Magnetic Resonance Imaging (tMRI) using Optical Flow (OF) techniques. For applications of OF in a clinical setting it is important to assess to what extent the performance of a particular OF method is stable across dierent clinical acquisition artifacts. This paper presents a statistical validation framework, based on ANOVA, to assess the motion and appearance factors that have the largest in uence on OF accuracy drop.
In order to validate this framework, we created a database of simulated tMRI data including the most common artifacts of MRI and test three dierent OF methods, including HARP.
Keywords: Optical flow; Performance Evaluation; Synthetic Database; ANOVA; Tagging Magnetic Resonance Imaging
|
|
|
Patricia Marquez, Debora Gil, R.Mester and Aura Hernandez-Sabate. 2014. Local Analysis of Confidence Measures for Optical Flow Quality Evaluation. 9th International Conference on Computer Vision Theory and Applications.450–457.
Abstract: Optical Flow (OF) techniques facing the complexity of real sequences have been developed in the last years. Even using the most appropriate technique for our specific problem, at some points the output flow might fail to achieve the minimum error required for the system. Confidence measures computed from either input data or OF output should discard those points where OF is not accurate enough for its further use. It follows that evaluating the capabilities of a confidence measure for bounding OF error is as important as the definition
itself. In this paper we analyze different confidence measures and point out their advantages and limitations for their use in real world settings. We also explore the agreement with current tools for their evaluation of confidence measures performance.
Keywords: Optical Flow; Confidence Measure; Performance Evaluation.
|
|
|
Patricia Marquez, Debora Gil, Aura Hernandez-Sabate and Daniel Kondermann. 2013. When Is A Confidence Measure Good Enough? 9th International Conference on Computer Vision Systems. Springer Link, 344–353. (LNCS.)
Abstract: Confidence estimation has recently become a hot topic in image processing and computer vision.Yet, several definitions exist of the term “confidence” which are sometimes used interchangeably. This is a position paper, in which we aim to give an overview on existing definitions,
thereby clarifying the meaning of the used terms to facilitate further research in this field. Based on these clarifications, we develop a theory to compare confidence measures with respect to their quality.
Keywords: Optical flow, confidence measure, performance evaluation
|
|
|
Patricia Marquez, Debora Gil and Aura Hernandez-Sabate. 2011. A Confidence Measure for Assessing Optical Flow Accuracy in the Absence of Ground Truth. IEEE International Conference on Computer Vision – Workshops. Barcelona (Spain), IEEE, 2042–2049.
Abstract: Optical flow is a valuable tool for motion analysis in autonomous navigation systems. A reliable application requires determining the accuracy of the computed optical flow. This is a main challenge given the absence of ground truth in real world sequences. This paper introduces a measure of optical flow accuracy for Lucas-Kanade based flows in terms of the numerical stability of the data-term. We call this measure optical flow condition number. A statistical analysis over ground-truth data show a good statistical correlation between the condition number and optical flow error. Experiments on driving sequences illustrate its potential for autonomous navigation systems.
Keywords: IEEE International Conference on Computer Vision – Workshops
|
|
|
Patricia Marquez, Debora Gil and Aura Hernandez-Sabate. 2013. Evaluation of the Capabilities of Confidence Measures for Assessing Optical Flow Quality. ICCV Workshop on Computer Vision in Vehicle Technology: From Earth to Mars.624–631.
Abstract: Assessing Optical Flow (OF) quality is essential for its further use in reliable decision support systems. The absence of ground truth in such situations leads to the computation of OF Confidence Measures (CM) obtained from either input or output data. A fair comparison across the capabilities of the different CM for bounding OF error is required in order to choose the best OF-CM pair for discarding points where OF computation is not reliable. This paper presents a statistical probabilistic framework for assessing the quality of a given CM. Our quality measure is given in terms of the percentage of pixels whose OF error bound can not be determined by CM values. We also provide statistical tools for the computation of CM values that ensures a given accuracy of the flow field.
|
|
|
P. Ricaurte, C. Chilan, Cristhian A. Aguilera-Carrasco, Boris X. Vintimilla and Angel Sappa. 2014. Performance Evaluation of Feature Point Descriptors in the Infrared Domain. 9th International Conference on Computer Vision Theory and Applications.545–550.
Abstract: This paper presents a comparative evaluation of classical feature point descriptors when they are used in the long-wave infrared spectral band. Robustness to changes in rotation, scaling, blur, and additive noise are evaluated using a state of the art framework. Statistical results using an outdoor image data set are presented together with a discussion about the differences with respect to the results obtained when images from the visible spectrum are considered.
Keywords: Infrared Imaging; Feature Point Descriptors
|
|
|
Oriol Rodriguez-Leon and 10 others. 2002. Ecografia Intracoronària: Segmentació Automàtica de area de la llum. XXXVIII Congreso Nacional de la Sociedad Española de Cardiología..
|
|