|
Records |
Links |
|
Author |
Debora Gil; Antonio Esteban Lansaque; Sebastian Stefaniga; Mihail Gaianu; Carles Sanchez |
|
|
Title |
Data Augmentation from Sketch |
Type |
Conference Article |
|
Year |
2019 |
Publication |
International Workshop on Uncertainty for Safe Utilization of Machine Learning in Medical Imaging |
Abbreviated Journal |
|
|
|
Volume |
11840 |
Issue |
|
Pages |
155-162 |
|
|
Keywords |
Data augmentation; cycleGANs; Multi-objective optimization |
|
|
Abstract |
State of the art machine learning methods need huge amounts of data with unambiguous annotations for their training. In the context of medical imaging this is, in general, a very difficult task due to limited access to clinical data, the time required for manual annotations and variability across experts. Simulated data could serve for data augmentation provided that its appearance was comparable to the actual appearance of intra-operative acquisitions. Generative Adversarial Networks (GANs) are a powerful tool for artistic style transfer, but lack a criteria for selecting epochs ensuring also preservation of intra-operative content.
We propose a multi-objective optimization strategy for a selection of cycleGAN epochs ensuring a mapping between virtual images and the intra-operative domain preserving anatomical content. Our approach has been applied to simulate intra-operative bronchoscopic videos and chest CT scans from virtual sketches generated using simple graphical primitives. |
|
|
Address |
Shenzhen; China; October 2019 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
CLIP |
|
|
Notes |
IAM; 600.145; 601.337; 600.139; 600.145 |
Approved |
no |
|
|
Call Number |
Admin @ si @ GES2019 |
Serial |
3359 |
|
Permanent link to this record |
|
|
|
|
Author |
Guillermo Torres; Debora Gil |
|
|
Title |
A multi-shape loss function with adaptive class balancing for the segmentation of lung structures |
Type |
Journal Article |
|
Year |
2020 |
Publication |
International Journal of Computer Assisted Radiology and Surgery |
Abbreviated Journal |
IJCAR |
|
|
Volume |
15 |
Issue |
1 |
Pages |
S154-55 |
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
Admin @ si @ ToG2020 |
Serial |
3590 |
|
Permanent link to this record |
|
|
|
|
Author |
Carles Sanchez; Debora Gil; Antoni Rosell; Albert Andaluz; F. Javier Sanchez |
|
|
Title |
Segmentation of Tracheal Rings in Videobronchoscopy combining Geometry and Appearance |
Type |
Conference Article |
|
Year |
2013 |
Publication |
Proceedings of the International Conference on Computer Vision Theory and Applications |
Abbreviated Journal |
|
|
|
Volume |
1 |
Issue |
|
Pages |
153--161 |
|
|
Keywords |
Video-bronchoscopy, tracheal ring segmentation, trachea geometric and appearance model |
|
|
Abstract |
Videobronchoscopy is a medical imaging technique that allows interactive navigation inside the respiratory pathways and minimal invasive interventions. Tracheal procedures are ordinary interventions that require measurement of the percentage of obstructed pathway for injury (stenosis) assessment. Visual assessment of stenosis in videobronchoscopic sequences requires high expertise of trachea anatomy and is prone to human error. Accurate detection of tracheal rings is the basis for automated estimation of the size of stenosed trachea. Processing of videobronchoscopic images acquired at the operating room is a challenging task due to the wide range of artifacts and acquisition conditions. We present a model of the geometric-appearance of tracheal rings for its detection in videobronchoscopic videos. Experiments on sequences acquired at the operating room, show a performance close to inter-observer variability |
|
|
Address |
Barcelona; February 2013 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
SciTePress |
Place of Publication |
Portugal |
Editor |
Sebastiano Battiato and José Braz |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-989-8565-47-1 |
Medium |
|
|
|
Area |
800 |
Expedition |
|
Conference |
VISAPP |
|
|
Notes |
IAM;MV; 600.044; 600.047; 600.060; 605.203 |
Approved |
no |
|
|
Call Number |
IAM @ iam @ SGR2013 |
Serial |
2123 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Oriol Ramos Terrades; Elisa Minchole; Carles Sanchez; Noelia Cubero de Frutos; Marta Diez-Ferrer; Rosa Maria Ortiz; Antoni Rosell |
|
|
Title |
Classification of Confocal Endomicroscopy Patterns for Diagnosis of Lung Cancer |
Type |
Conference Article |
|
Year |
2017 |
Publication |
6th Workshop on Clinical Image-based Procedures: Translational Research in Medical Imaging |
Abbreviated Journal |
|
|
|
Volume |
10550 |
Issue |
|
Pages |
151-159 |
|
|
Keywords |
|
|
|
Abstract |
Confocal Laser Endomicroscopy (CLE) is an emerging imaging technique that allows the in-vivo acquisition of cell patterns of potentially malignant lesions. Such patterns could discriminate between inflammatory and neoplastic lesions and, thus, serve as a first in-vivo biopsy to discard cases that do not actually require a cell biopsy.
The goal of this work is to explore whether CLE images obtained during videobronchoscopy contain enough visual information to discriminate between benign and malign peripheral lesions for lung cancer diagnosis. To do so, we have performed a pilot comparative study with 12 patients (6 adenocarcinoma and 6 benign-inflammatory) using 2 different methods for CLE pattern analysis: visual analysis by 3 experts and a novel methodology that uses graph methods to find patterns in pre-trained feature spaces. Our preliminary results indicate that although visual analysis can only achieve a 60.2% of accuracy, the accuracy of the proposed unsupervised image pattern classification raises to 84.6%.
We conclude that CLE images visual information allow in-vivo detection of neoplastic lesions and graph structural analysis applied to deep-learning feature spaces can achieve competitive results. |
|
|
Address |
Quebec; Canada; September 2017 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
CLIP |
|
|
Notes |
IAM; 600.096; 600.075; 600.145 |
Approved |
no |
|
|
Call Number |
Admin @ si @ GRM2017 |
Serial |
2957 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; F. Javier Sanchez; Gloria Fernandez Esparrach; Jorge Bernal |
|
|
Title |
3D Stable Spatio-temporal Polyp Localization in Colonoscopy Videos |
Type |
Book Chapter |
|
Year |
2015 |
Publication |
Computer-Assisted and Robotic Endoscopy. Revised selected papers of Second International Workshop, CARE 2015, Held in Conjunction with MICCAI 2015 |
Abbreviated Journal |
|
|
|
Volume |
9515 |
Issue |
|
Pages |
140-152 |
|
|
Keywords |
Colonoscopy, Polyp Detection, Polyp Localization, Region Extraction, Watersheds |
|
|
Abstract |
Computational intelligent systems could reduce polyp miss rate in colonoscopy for colon cancer diagnosis and, thus, increase the efficiency of the procedure. One of the main problems of existing polyp localization methods is a lack of spatio-temporal stability in their response. We propose to explore the response of a given polyp localization across temporal windows in order to select
those image regions presenting the highest stable spatio-temporal response.
Spatio-temporal stability is achieved by extracting 3D watershed regions on the
temporal window. Stability in localization response is statistically determined by analysis of the variance of the output of the localization method inside each 3D region. We have explored the benefits of considering spatio-temporal stability in two different tasks: polyp localization and polyp detection. Experimental results indicate an average improvement of 21:5% in polyp localization and 43:78% in polyp detection. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
CARE |
|
|
Notes |
IAM; MV; 600.075 |
Approved |
no |
|
|
Call Number |
Admin @ si @ GSF2015 |
Serial |
2733 |
|
Permanent link to this record |
|
|
|
|
Author |
Jaume Garcia; Debora Gil; Francesc Carreras; Sandra Pujades; R.Leta |
|
|
Title |
Modelització 4-Dimensional de la Funció Siatólica del Ventricle Esquerre |
Type |
Conference Article |
|
Year |
2007 |
Publication |
XIX Congrés de la Societat Catalana de Cardiologia de Barcelona |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
133-134 |
|
|
Keywords |
|
|
|
Abstract |
L’evolució tecnològica en el tractament de les imatges mèdiques permet reconstruir, amb el software apropiat, imatges tridimensionals de les estructures cardiovasculars i dotar-les de moviment. Les imatges 4D resultants faciliten l’estudi de la fisiopatologia de la insuficiència cardíaca en base als transtorns de l’activació electromecànica ventricular, el que pot ser d’interès en el procés de selecció de pacients candidats a teràpies de resincronització. Presentem els resultats preliminars de la reconstrucció 4D del ventricle esquerre (VE) a partir de les seqüències de tagging miocàrdic del VE. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Barcelona (Spain) |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GGC2007 |
Serial |
1505 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Petia Radeva; J. Mauri |
|
|
Title |
Ivus Segmentation Via a Regularized Curvature Flow |
Type |
Conference Article |
|
Year |
2002 |
Publication |
X Congreso Anual de la Sociedad Española de Ingeniería Biomédica CASEIB 2002 |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
133-136 |
|
|
Keywords |
|
|
|
Abstract |
Cardiac diseases are diagnosed and treated through a study of the morphology and dynamics of cardiac arteries. In- travascular Ultrasound (IVUS) imaging is of high interest to physicians since it provides both information. At the current state-of-the-art in image segmentation, a robust detection of the arterial lumen in IVUS demands manual intervention or ECG-gating. Manual intervention is a tedious and time consuming task that requires experienced observers, meanwhile ECG-gating is an acquisition technique not available in all clinical centers. We introduce a parametric algorithm that detects the arterial luminal border in in vivo sequences. The method consist in smoothing the sequences’ level surfaces under a regularized mean curvature flow that admits non-trivial steady states. The flow is based on a measure of the surface local smoothness that takes into account regularity of the surface curvature. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Saragossa, Espanya |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GRM2002 |
Serial |
1536 |
|
Permanent link to this record |
|
|
|
|
Author |
Oriol Rodriguez-Leor; Debora Gil; Eduard Fernandez-Nofrerias; H. Tizon; S. Montserrat; Vicente del Valle; J. Mauri |
|
|
Title |
Caracterització de la Perfusió Miocàrdica mitjançant anàlisi estadístic de l espectre en l angiografia de contrast |
Type |
Conference Article |
|
Year |
2007 |
Publication |
XIX Congrés de la Societat Catalana de Cardiologia de Barcelona |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
130 |
|
|
Keywords |
|
|
|
Abstract |
La valoració de la integritat de la microcirculació coronària aporta informació pronòstica en pacients amb infart agut de miocardi en els que es realitza angioplastia primària. Aquesta valoració és subjectiva i presenta una important variabilitat si no es duta a terme per personal experimentat. Presentem una eina d’anàlisi d’imatge que permet fer una valoració de la microcirculació coronària a partir de seqüències d’angiografia. Hem analitzat les variacions locals en el nivell de gris de la imatge durant la seqüència angiogràfica. Hem identificat els principals fenòmens observats (respiració, batec cardíac, tinció arterial, tinció miocàrdica i soroll radiològic) mitjançant un anàlisi estadístic de l’espectre de Fourier de l’evolució al llarg del temps de la mitja local. Aquest mateix anàlisis permet determinat la influència de cadascun d’ells en la extracció del patró de tinció i selecciona la respiració com el fenomen que més distorsiona el patró de tinció original. Els descriptors proposats s’obtenen fora del rang espectral respiratori. Hem testat la seva capacitat per a detectar els tres fenòmens principals (tinció miocàrdica (MS), tinció arterial (AS) i soroll (NS)) independentment de la respiració. La capacitat de discriminació dels descriptors ha estat valorada mitjançant un mètode de crossvalidation en 30 seqüències d’angiografia. Els descriptors emprats permeten caracteritzar la tinció miocàrdica amb una alta eficiència i fiabilitat. A més no hi ha diferències significatives en l’anàlisi de les seqüències obtingudes amb el pacient respirant amb normalitat o en apnea |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Barcelona (Spain) |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RGF2007 |
Serial |
1639 |
|
Permanent link to this record |
|
|
|
|
Author |
Oriol Rodriguez-Leor; Debora Gil; Eduard Fernandez-Nofrerias |
|
|
Title |
Analisis en los cambios en el nivel de gris en las secuencias angiograficas mediante descriptores estadisticos para determinar la perfusion miocardica |
Type |
Journal Article |
|
Year |
2006 |
Publication |
Revista Española de Cardiología |
Abbreviated Journal |
REC |
|
|
Volume |
59 Supl 2-166 |
Issue |
2 |
Pages |
128 |
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RGF2006 |
Serial |
1640 |
|
Permanent link to this record |
|
|
|
|
Author |
Jaume Garcia; Debora Gil; Aura Hernandez-Sabate |
|
|
Title |
Endowing Canonical Geometries to Cardiac Structures |
Type |
Book Chapter |
|
Year |
2010 |
Publication |
Statistical Atlases And Computational Models Of The Heart |
Abbreviated Journal |
|
|
|
Volume |
6364 |
Issue |
|
Pages |
124-133 |
|
|
Keywords |
|
|
|
Abstract |
International conference on Cardiac electrophysiological simulation challenge
In this paper, we show that canonical (shape-based) geometries can be endowed to cardiac structures using tubular coordinates defined over their medial axis. We give an analytic formulation of these geometries by means of B-Splines. Since B-Splines present vector space structure PCA can be applied to their control points and statistical models relating boundaries and the interior of the anatomical structures can be derived. We demonstrate the applicability in two cardiac structures, the 3D Left Ventricular volume, and the 2D Left-Right ventricle set in 2D Short Axis view. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Berlin / Heidelberg |
Place of Publication |
|
Editor |
Camara, O.; Pop, M.; Rhode, K.; Sermesant, M.; Smith, N.; Young, A. |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
Lecture Notes in Computer Science |
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GGH2010b |
Serial |
1515 |
|
Permanent link to this record |