|
Jorge Bernal, F. Javier Sanchez, Gloria Fernandez Esparrach, Debora Gil, Cristina Rodriguez de Miguel, & Fernando Vilariño. (2015). WM-DOVA Maps for Accurate Polyp Highlighting in Colonoscopy: Validation vs. Saliency Maps from Physicians. CMIG - Computerized Medical Imaging and Graphics, 43, 99–111.
Abstract: We introduce in this paper a novel polyp localization method for colonoscopy videos. Our method is based on a model of appearance for polyps which defines polyp boundaries in terms of valley information. We propose the integration of valley information in a robust way fostering complete, concave and continuous boundaries typically associated to polyps. This integration is done by using a window of radial sectors which accumulate valley information to create WMDOVA1 energy maps related with the likelihood of polyp presence. We perform a double validation of our maps, which include the introduction of two new databases, including the first, up to our knowledge, fully annotated database with clinical metadata associated. First we assess that the highest value corresponds with the location of the polyp in the image. Second, we show that WM-DOVA energy maps can be comparable with saliency maps obtained from physicians' fixations obtained via an eye-tracker. Finally, we prove that our method outperforms state-of-the-art computational saliency results. Our method shows good performance, particularly for small polyps which are reported to be the main sources of polyp miss-rate, which indicates the potential applicability of our method in clinical practice.
Keywords: Polyp localization; Energy Maps; Colonoscopy; Saliency; Valley detection
|
|
|
Jose Elias Yauri, Aura Hernandez-Sabate, Pau Folch, & Debora Gil. (2021). Mental Workload Detection Based on EEG Analysis. In Artificial Intelligent Research and Development. Proceedings 23rd International Conference of the Catalan Association for Artificial Intelligence. (Vol. 339, pp. 268–277).
Abstract: The study of mental workload becomes essential for human work efficiency, health conditions and to avoid accidents, since workload compromises both performance and awareness. Although workload has been widely studied using several physiological measures, minimising the sensor network as much as possible remains both a challenge and a requirement.
Electroencephalogram (EEG) signals have shown a high correlation to specific cognitive and mental states like workload. However, there is not enough evidence in the literature to validate how well models generalize in case of new subjects performing tasks of a workload similar to the ones included during model’s training.
In this paper we propose a binary neural network to classify EEG features across different mental workloads. Two workloads, low and medium, are induced using two variants of the N-Back Test. The proposed model was validated in a dataset collected from 16 subjects and shown a high level of generalization capability: model reported an average recall of 81.81% in a leave-one-out subject evaluation.
Keywords: Cognitive states; Mental workload; EEG analysis; Neural Networks.
|
|
|
Josefina Mauri, Eduard Fernandez-Nofrerias, J. Comin, B. Garcia del Blanco, E. Iraculis, J.A. Gomez-Hospital, et al. (2000). Avaluació del Conjunt Stent/Artèria mitjançant ecografia intracoronària: lentorn informàtic. In Congrés de la Societat Catalana de Cardiologia..
|
|
|
Josefina Mauri, Eduard Fernandez-Nofrerias, B. Garcia del Blanco, E. Iraculis, J.A. Gomez-Hospital, J. Comin, et al. (2000). Moviment del vas en l anàlisi d imatges d ecografia intracoronària: un model matemàtic. In Congrés de la Societat Catalana de Cardiologia..
|
|
|
Juan Borrego-Carazo, Carles Sanchez, David Castells, Jordi Carrabina, & Debora Gil. (2023). BronchoPose: an analysis of data and model configuration for vision-based bronchoscopy pose estimation. CMPB - Computer Methods and Programs in Biomedicine, 228, 107241.
Abstract: Vision-based bronchoscopy (VB) models require the registration of the virtual lung model with the frames from the video bronchoscopy to provide effective guidance during the biopsy. The registration can be achieved by either tracking the position and orientation of the bronchoscopy camera or by calibrating its deviation from the pose (position and orientation) simulated in the virtual lung model. Recent advances in neural networks and temporal image processing have provided new opportunities for guided bronchoscopy. However, such progress has been hindered by the lack of comparative experimental conditions.
In the present paper, we share a novel synthetic dataset allowing for a fair comparison of methods. Moreover, this paper investigates several neural network architectures for the learning of temporal information at different levels of subject personalization. In order to improve orientation measurement, we also present a standardized comparison framework and a novel metric for camera orientation learning. Results on the dataset show that the proposed metric and architectures, as well as the standardized conditions, provide notable improvements to current state-of-the-art camera pose estimation in video bronchoscopy.
Keywords: Videobronchoscopy guiding; Deep learning; Architecture optimization; Datasets; Standardized evaluation framework; Pose estimation
|
|
|
Juan Borrego-Carazo, Carles Sanchez, David Castells, Jordi Carrabina, & Debora Gil. (2022). A benchmark for the evaluation of computational methods for bronchoscopic navigation. IJCARS - International Journal of Computer Assisted Radiology and Surgery, 17(1).
|
|
|
Katerine Diaz, Jesus Martinez del Rincon, Aura Hernandez-Sabate, & Debora Gil. (2018). Continuous head pose estimation using manifold subspace embedding and multivariate regression. ACCESS - IEEE Access, 6, 18325–18334.
Abstract: In this paper, a continuous head pose estimation system is proposed to estimate yaw and pitch head angles from raw facial images. Our approach is based on manifold learningbased methods, due to their promising generalization properties shown for face modelling from images. The method combines histograms of oriented gradients, generalized discriminative common vectors and continuous local regression to achieve successful performance. Our proposal was tested on multiple standard face datasets, as well as in a realistic scenario. Results show a considerable performance improvement and a higher consistence of our model in comparison with other state-of-art methods, with angular errors varying between 9 and 17 degrees.
Keywords: Head Pose estimation; HOG features; Generalized Discriminative Common Vectors; B-splines; Multiple linear regression
|
|
|
M.Gomez, Josefina Mauri, Eduard Fernandez-Nofrerias, Oriol Rodriguez-Leon, Carme Julia, Debora Gil, et al. (2002). Reconstrucción de un modelo espacio-temporal de la luz del vaso a partir de secuencias de ecografía intracoronaria. In XXXVIII Congreso Nacional de la Sociedad Española de Cardiología..
|
|
|
Mariano Vazquez, Ruth Aris, Guillaume Hozeaux, R.Aubry, P.Villar, Jaume Garcia, et al. (2011). A massively parallel computational electrophysiology model of the heart. IJNMBE - International Journal for Numerical Methods in Biomedical Engineering, 27, 1911–1929.
Abstract: This paper presents a patient-sensitive simulation strategy capable of using the most efficient way the high-performance computational resources. The proposed strategy directly involves three different players: Computational Mechanics Scientists (CMS), Image Processing Scientists and Cardiologists, each one mastering its own expertise area within the project. This paper describes the general integrative scheme but focusing on the CMS side presents a massively parallel implementation of computational electrophysiology applied to cardiac tissue simulation. The paper covers different angles of the computational problem: equations, numerical issues, the algorithm and parallel implementation. The proposed methodology is illustrated with numerical simulations testing all the different possibilities, ranging from small domains up to very large ones. A key issue is the almost ideal scalability not only for large and complex problems but also for medium-size meshes. The explicit formulation is particularly well suited for solving this highly transient problems, with very short time-scale.
Keywords: computational electrophysiology; parallelization; finite element methods
|
|
|
Marta Diez-Ferrer, Arturo Morales, Rosa Lopez Lisbona, Noelia Cubero, Cristian Tebe, Susana Padrones, et al. (2019). Ultrathin Bronchoscopy with and without Virtual Bronchoscopic Navigation: Influence of Segmentation on Diagnostic Yield. RES - Respiration, 97(3), 252–258.
Abstract: Background: Bronchoscopy is a safe technique for diagnosing peripheral pulmonary lesions (PPLs), and virtual bronchoscopic navigation (VBN) helps guide the bronchoscope to PPLs. Objectives: We aimed to compare the diagnostic yield of VBN-guided and unguided ultrathin bronchoscopy (UTB) and explore clinical and technical factors associated with better results. We developed a diagnostic algorithm for deciding whether to use VBN to reach PPLs or choose an alternative diagnostic approach. Methods: We compared diagnostic yield between VBN-UTB (prospective cases) and unguided UTB (historical controls) and analyzed the VBN-UTB subgroup to identify clinical and technical variables that could predict the success of VBN-UTB. Results: Fifty-five cases and 110 controls were included. The overall diagnostic yield did not differ between the VBN-guided and unguided arms (47 and 40%, respectively; p = 0.354). Although the yield was slightly higher for PPLs ≤20 mm in the VBN-UTB arm, the difference was not significant (p = 0.069). No other clinical characteristics were associated with a higher yield in a subgroup analysis, but an 85% diagnostic yield was observed when segmentation was optimal and the PPL was endobronchial (vs. 30% when segmentation was suboptimal and 20% when segmentation was optimal but the PPL was extrabronchial). Conclusions: VBN-guided UTB is not superior to unguided UTB. A greater impact of VBN-guided over unguided UTB is highly dependent on both segmentation quality and an endobronchial location of the PPL. Segmentation quality should be considered before starting a procedure, when an alternative technique that may improve yield can be chosen, saving time and resources.
Keywords: Lung cancer; Peripheral lung lesion; Diagnosis; Bronchoscopy; Ultrathin bronchoscopy; Virtual bronchoscopic navigation
|
|
|
Marta Diez-Ferrer, Debora Gil, Cristian Tebe, & Carles Sanchez. (2018). Positive Airway Pressure to Enhance Computed Tomography Imaging for Airway Segmentation for Virtual Bronchoscopic Navigation. RES - Respiration, 96(6), 525–534.
Abstract: Abstract
RATIONALE:
Virtual bronchoscopic navigation (VBN) guidance to peripheral pulmonary lesions is often limited by insufficient segmentation of the peripheral airways.
OBJECTIVES:
To test the effect of applying positive airway pressure (PAP) during CT acquisition to improve segmentation, particularly at end-expiration.
METHODS:
CT acquisitions in inspiration and expiration with 4 PAP protocols were recorded prospectively and compared to baseline inspiratory acquisitions in 20 patients. The 4 protocols explored differences between devices (flow vs. turbine), exposures (within seconds vs. 15-min) and pressure levels (10 vs. 14 cmH2O). Segmentation quality was evaluated with the number of airways and number of endpoints reached. A generalized mixed-effects model explored the estimated effect of each protocol.
MEASUREMENTS AND MAIN RESULTS:
Patient characteristics and lung function did not significantly differ between protocols. Compared to baseline inspiratory acquisitions, expiratory acquisitions after 15 min of 14 cmH2O PAP segmented 1.63-fold more airways (95% CI 1.07-2.48; p = 0.018) and reached 1.34-fold more endpoints (95% CI 1.08-1.66; p = 0.004). Inspiratory acquisitions performed immediately under 10 cmH2O PAP reached 1.20-fold (95% CI 1.09-1.33; p < 0.001) more endpoints; after 15 min the increase was 1.14-fold (95% CI 1.05-1.24; p < 0.001).
CONCLUSIONS:
CT acquisitions with PAP segment more airways and reach more endpoints than baseline inspiratory acquisitions. The improvement is particularly evident at end-expiration after 15 min of 14 cmH2O PAP. Further studies must confirm that the improvement increases diagnostic yield when using VBN to evaluate peripheral pulmonary lesions.
Keywords: Multidetector computed tomography; Bronchoscopy; Continuous positive airway pressure; Image enhancement; Virtual bronchoscopic navigation
|
|
|
Marta Diez-Ferrer, Debora Gil, Elena Carreño, Susana Padrones, & Samantha Aso. (2017). Positive Airway Pressure-Enhanced CT to Improve Virtual Bronchoscopic Navigation. JTO - Journal of Thoracic Oncology, 12(1S), S596–S597.
Abstract: A main weakness of virtual bronchoscopic navigation (VBN) is unsuccessful segmentation of distal branches approaching peripheral pulmonary nodules (PPN). CT scan acquisition protocol is pivotal for segmentation covering the utmost periphery. We hypothesize that application of continuous positive airway pressure (CPAP) during CT acquisition could improve visualization and segmentation of peripheral bronchi. The purpose of the present pilot study is to compare quality of segmentations under 4 CT acquisition modes: inspiration (INSP), expiration (EXP) and both with CPAP (INSP-CPAP and EXP-CPAP).
Keywords: Thorax CT; diagnosis; Peripheral Pulmonary Nodule
|
|
|
Marta Diez-Ferrer, Debora Gil, Elena Carreño, Susana Padrones, Samantha Aso, Vanesa Vicens, et al. (2016). Positive Airway Pressure-Enhanced CT to Improve Virtual Bronchoscopic Navigation. CHEST - Chest Journal, 150(4), 1003A.
|
|
|
Marta Diez-Ferrer, Debora Gil, Elena Carreño, Susana Padrones, Samantha Aso, Vanesa Vicens, et al. (2017). Positive Airway Pressure-Enhanced CT to Improve Virtual Bronchoscopic Navigation. ERJ - European Respiratory Journal, .
|
|
|
Marta Ligero, Alonso Garcia Ruiz, Cristina Viaplana, Guillermo Villacampa, Maria V Raciti, Jaid Landa, et al. (2021). A CT-based radiomics signature is associated with response to immune checkpoint inhibitors in advanced solid tumors. Radiology, 299(1), 109–119.
Abstract: Background Reliable predictive imaging markers of response to immune checkpoint inhibitors are needed. Purpose To develop and validate a pretreatment CT-based radiomics signature to predict response to immune checkpoint inhibitors in advanced solid tumors. Materials and Methods In this retrospective study, a radiomics signature was developed in patients with advanced solid tumors (including breast, cervix, gastrointestinal) treated with anti-programmed cell death-1 or programmed cell death ligand-1 monotherapy from August 2012 to May 2018 (cohort 1). This was tested in patients with bladder and lung cancer (cohorts 2 and 3). Radiomics variables were extracted from all metastases delineated at pretreatment CT and selected by using an elastic-net model. A regression model combined radiomics and clinical variables with response as the end point. Biologic validation of the radiomics score with RNA profiling of cytotoxic cells (cohort 4) was assessed with Mann-Whitney analysis. Results The radiomics signature was developed in 85 patients (cohort 1: mean age, 58 years ± 13 [standard deviation]; 43 men) and tested on 46 patients (cohort 2: mean age, 70 years ± 12; 37 men) and 47 patients (cohort 3: mean age, 64 years ± 11; 40 men). Biologic validation was performed in a further cohort of 20 patients (cohort 4: mean age, 60 years ± 13; 14 men). The radiomics signature was associated with clinical response to immune checkpoint inhibitors (area under the curve [AUC], 0.70; 95% CI: 0.64, 0.77; P < .001). In cohorts 2 and 3, the AUC was 0.67 (95% CI: 0.58, 0.76) and 0.67 (95% CI: 0.56, 0.77; P < .001), respectively. A radiomics-clinical signature (including baseline albumin level and lymphocyte count) improved on radiomics-only performance (AUC, 0.74 [95% CI: 0.63, 0.84; P < .001]; Akaike information criterion, 107.00 and 109.90, respectively). Conclusion A pretreatment CT-based radiomics signature is associated with response to immune checkpoint inhibitors, likely reflecting the tumor immunophenotype. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Summers in this issue.
|
|