Ferran Poveda, Debora Gil, Albert Andaluz, & Enric Marti. (2011). "Multiscale Tractography for Representing Heart Muscular Architecture " In In MICCAI 2011 Workshop on Computational Diffusion MRI.
Abstract: Deep understanding of myocardial structure of the heart would unravel crucial knowledge for clinical and medical procedures. Although the muscular architecture of the heart has been debated by countless researchers, the controversy is still alive. Diffusion Tensor MRI, DT-MRI, is a unique imaging technique for computational validation of the muscular structure of the heart. By the complex arrangement of myocites, existing techniques can not provide comprehensive descriptions of the global muscular architecture. In this paper we introduce a multiresolution reconstruction technique based on DT-MRI streamlining for simplified global myocardial model generation. Our reconstructions can restore the most complex myocardial structures and indicate a global helical organization
|
|
|
Patricia Marquez, Debora Gil, & Aura Hernandez-Sabate. (2011). "A Confidence Measure for Assessing Optical Flow Accuracy in the Absence of Ground Truth " In IEEE International Conference on Computer Vision – Workshops (pp. 2042–2049). Barcelona (Spain): IEEE.
Abstract: Optical flow is a valuable tool for motion analysis in autonomous navigation systems. A reliable application requires determining the accuracy of the computed optical flow. This is a main challenge given the absence of ground truth in real world sequences. This paper introduces a measure of optical flow accuracy for Lucas-Kanade based flows in terms of the numerical stability of the data-term. We call this measure optical flow condition number. A statistical analysis over ground-truth data show a good statistical correlation between the condition number and optical flow error. Experiments on driving sequences illustrate its potential for autonomous navigation systems.
Keywords: IEEE International Conference on Computer Vision – Workshops
|
|
|
Aura Hernandez-Sabate, & Debora Gil. (2012). "The Benefits of IVUS Dynamics for Retrieving Stable Models of Arteries " In Yasuhiro Honda (Ed.), Intravascular Ultrasound (pp. 185–206). Intech.
|
|
|
Eric Amiel. (2005). "Visualisation de vaisseaux sanguins " (Enric Marti, Ed.). Bachelor's thesis, Université Paul Sabatier Toulouse III, Toulouse.
|
|
|
Sergio Vera, Debora Gil, Antonio Lopez, & Miguel Angel Gonzalez Ballester. (2012). "Multilocal Creaseness Measure " . The Insight Journal, .
Abstract: This document describes the implementation using the Insight Toolkit of an algorithm for detecting creases (ridges and valleys) in N-dimensional images, based on the Local Structure Tensor of the image. In addition to the filter used to calculate the creaseness image, a filter for the computation of the structure tensor is also included in this submission.
Keywords: Ridges, Valley, Creaseness, Structure Tensor, Skeleton,
|
|
|
Carles Sanchez. (2011). "Tracheal ring detection in bronchoscopy " (F. J. S. Debora Gil, Ed.) (Vol. 168). Master's thesis, , .
Abstract: Endoscopy is the process in which a camera is introduced inside a human.
Given that endoscopy provides realistic images (in contrast to other modalities) and allows non-invase minimal intervention procedures (which can aid in diagnosis and surgical interventions), its use has spreaded during last decades.
In this project we will focus on bronchoscopic procedures, during which the camera is introduced through the trachea in order to have a diagnostic of the patient. The diagnostic interventions are focused on: degree of stenosis (reduction in tracheal area), prosthesis or early diagnosis of tumors. In the first case, assessment of the luminal area and the calculation of the diameters of the tracheal rings are required. A main limitation is that all the process is done by hand,
which means that the doctor takes all the measurements and decisions just by looking at the screen. As far as we know there is no computational framework for helping the doctors in the diagnosis.
This project will consist of analysing bronchoscopic videos in order to extract useful information for the diagnostic of the degree of stenosis. In particular we will focus on segmentation of the tracheal rings. As a result of this project several strategies (for detecting tracheal rings) had been implemented in order to compare their performance.
Keywords: Bronchoscopy, tracheal ring, segmentation
|
|
|
Ferran Poveda, Enric Marti, Debora Gil, Francesc Carreras, & Manel Ballester. (2012). "Helical Structure of Ventricular Anatomy by Diffusion Tensor Cardiac MR Tractography " . Journal of American College of Cardiology, 5(7), 754–755.
Abstract: It is widely accepted that myocardial fiber architecture plays a critical role in myocardial contractility and relaxation (1). However, there is a lack of consensus about the distribution of the myocardial fibers and their spatial arrangement in the left and right ventricles. An understanding of the cardiac architecture should benefit the ventricular functional assessment, left ventricular reconstructive surgery planning, or resynchronization therapy in heart failure. Researchers have proposed several conceptual models to describe the architecture of the heart, ranging from gross dissection to histological presentation. The cardiac mesh model (2) proposes that the myocytes are arranged longitudinally and radially change their angulation along the myocardial depth. By contrast, the helical ventricular myocardial model states that the ventricular myocardium is a continuous anatomical helical layout of myocardial fibers (1
|
|
|
Patricia Marquez, Debora Gil, & Aura Hernandez-Sabate. (2012). "A Complete Confidence Framework for Optical Flow " In Rita Cucchiara V. M. Andrea Fusiello (Ed.), 12th European Conference on Computer Vision – Workshops and Demonstrations (Vol. 7584, pp. 124–133). Florence, Italy, October 7-13, 2012: Springer-Verlag.
Abstract: Medial representations are powerful tools for describing and parameterizing the volumetric shape of anatomical structures. Existing methods show excellent results when applied to 2D objects, but their quality drops across dimensions. This paper contributes to the computation of medial manifolds in two aspects. First, we provide a standard scheme for the computation of medial manifolds that avoid degenerated medial axis segments; second, we introduce an energy based method which performs independently of the dimension. We evaluate quantitatively the performance of our method with respect to existing approaches, by applying them to synthetic shapes of known medial geometry. Finally, we show results on shape representation of multiple abdominal organs, exploring the use of medial manifolds for the representation of multi-organ relations.
Keywords: Optical flow, confidence measures, sparsification plots, error prediction plots
|
|
|
David Roche, Debora Gil, & Jesus Giraldo. (2013). "Multiple active receptor conformation, agonist efficacy and maximum effect of the system: the conformation-based operational model of agonism, " . Drug Discovery Today, 18(7-8), 365–371.
Abstract: The operational model of agonism assumes that the maximum effect a particular receptor system can achieve (the Em parameter) is fixed. Em estimates are above but close to the asymptotic maximum effects of endogenous agonists. The concept of Em is contradicted by superagonists and those positive allosteric modulators that significantly increase the maximum effect of endogenous agonists. An extension of the operational model is proposed that assumes that the Em parameter does not necessarily have a single value for a receptor system but has multiple values associated to multiple active receptor conformations. The model provides a mechanistic link between active receptor conformation and agonist efficacy, which can be useful for the analysis of agonist response under different receptor scenarios.
|
|
|
Sergio Vera, Debora Gil, Agnes Borras, Marius George Linguraru, & Miguel Angel Gonzalez Ballester. (2013). "Geometric Steerable Medial Maps " . Machine Vision and Applications, 24(6), 1255–1266.
Abstract: In order to provide more intuitive and easily interpretable representations of complex shapes/organs, medial manifolds should reach a compromise between simplicity in geometry and capability for restoring the anatomy/shape of the organ/volume. Existing morphological methods show excellent results when applied to 2D objects, but their quality drops across dimensions.
This paper contributes to the computation of medial manifolds in two aspects. First, we provide a standard scheme for the computation of medial manifolds that avoids degenerated medial axis segments. Second, we introduce a continuous operator for accurate and efficient computation of medial structures of arbitrary dimension. We evaluate quantitatively the performance of our method with respect to existing approaches, by applying them to syn- thetic shapes of known medial geometry. We also show its higher performance for medical imaging applications in terms of simplicity of medial structures and capability for reconstructing the anatomical volume.
Keywords: Medial Representations ,Medial Manifolds Comparation , Surface , Reconstruction
|
|