|
Records |
Links |
|
Author |
Aura Hernandez-Sabate; David Rotger; Debora Gil |
|
|
Title |
Image-based ECG sampling of IVUS sequences |
Type |
Conference Article |
|
Year |
2008 |
Publication |
Proc. IEEE Ultrasonics Symp. IUS 2008 |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
1330-1333 |
|
|
Keywords |
Longitudinal Motion; Image-based ECG-gating; Fourier analysis |
|
|
Abstract |
Longitudinal motion artifacts in IntraVascular UltraSound (IVUS) sequences hinders a properly 3D reconstruction and vessel measurements. Most of current techniques base on the ECG signal to obtain a gated pullback without the longitudinal artifact by using a specific hardware or the ECG signal itself. The potential of IVUS images processing for phase retrieval still remains little explored. In this paper, we present a fast forward image-based algorithm to approach ECG sampling. Inspired on the fact that maximum and minimum lumen areas are related to end-systole and end-diastole, our cardiac phase retrieval is based on the analysis of tissue density of mass along the sequence. The comparison between automatic and manual phase retrieval (0.07 ± 0.07 mm. of error) encourages a deep validation contrasting with ECG signals. |
|
|
Address |
Beijing (China) |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ HRG2008 |
Serial |
1553 |
|
Permanent link to this record |
|
|
|
|
Author |
Oriol Rodriguez-Leor; Eduard Fernandez-Nofrerias; J. Mauri; Vicente del Valle; Debora Gil; A.Barrios; E.Garcia; Petia Radeva |
|
|
Title |
Perfusion ratio: A new tool to objectively assess microcirculation perfusion after primary Percutaneous Coronary Intervention |
Type |
Conference Article |
|
Year |
2006 |
Publication |
World Congress of Cardiology |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
859 |
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Barcelona (Spain) |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RFM2006c |
Serial |
1643 |
|
Permanent link to this record |
|
|
|
|
Author |
Oriol Rodriguez-Leor; J. Mauri; Eduard Fernandez-Nofrerias; Vicente de Valle; E. Garcia; A. Barrios; Debora Gil; Petia Radeva |
|
|
Title |
Analysis of the changes in angiography local grey-level values to determine myocardial perfusion |
Type |
Conference Article |
|
Year |
2006 |
Publication |
World Congress of Cardiology |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
862 |
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Barcelona (Spain) |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RMF2006 |
Serial |
1644 |
|
Permanent link to this record |
|
|
|
|
Author |
Carles Sanchez; Debora Gil; Antoni Rosell; Albert Andaluz; F. Javier Sanchez |
|
|
Title |
Segmentation of Tracheal Rings in Videobronchoscopy combining Geometry and Appearance |
Type |
Conference Article |
|
Year |
2013 |
Publication |
Proceedings of the International Conference on Computer Vision Theory and Applications |
Abbreviated Journal |
|
|
|
Volume |
1 |
Issue |
|
Pages |
153--161 |
|
|
Keywords |
Video-bronchoscopy, tracheal ring segmentation, trachea geometric and appearance model |
|
|
Abstract |
Videobronchoscopy is a medical imaging technique that allows interactive navigation inside the respiratory pathways and minimal invasive interventions. Tracheal procedures are ordinary interventions that require measurement of the percentage of obstructed pathway for injury (stenosis) assessment. Visual assessment of stenosis in videobronchoscopic sequences requires high expertise of trachea anatomy and is prone to human error. Accurate detection of tracheal rings is the basis for automated estimation of the size of stenosed trachea. Processing of videobronchoscopic images acquired at the operating room is a challenging task due to the wide range of artifacts and acquisition conditions. We present a model of the geometric-appearance of tracheal rings for its detection in videobronchoscopic videos. Experiments on sequences acquired at the operating room, show a performance close to inter-observer variability |
|
|
Address |
Barcelona; February 2013 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
SciTePress |
Place of Publication |
Portugal |
Editor |
Sebastiano Battiato and José Braz |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-989-8565-47-1 |
Medium |
|
|
|
Area |
800 |
Expedition |
|
Conference |
VISAPP |
|
|
Notes |
IAM;MV; 600.044; 600.047; 600.060; 605.203 |
Approved |
no |
|
|
Call Number |
IAM @ iam @ SGR2013 |
Serial |
2123 |
|
Permanent link to this record |
|
|
|
|
Author |
Joan M. Nuñez; Debora Gil; Fernando Vilariño |
|
|
Title |
Finger joint characterization from X-ray images for rheymatoid arthritis assessment |
Type |
Conference Article |
|
Year |
2013 |
Publication |
6th International Conference on Biomedical Electronics and Devices |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
288-292 |
|
|
Keywords |
Rheumatoid Arthritis; X-Ray; Hand Joint; Sclerosis; Sharp Van der Heijde |
|
|
Abstract |
In this study we propose amodular systemfor automatic rheumatoid arthritis assessment which provides a joint space width measure. A hand joint model is proposed based on the accurate analysis of a X-ray finger joint image sample set. This model shows that the sclerosis and the lower bone are the main necessary features in order to perform a proper finger joint characterization. We propose sclerosis and lower bone detection methods as well as the experimental setup necessary for its performance assessment. Our characterization is used to propose and compute a joint space width score which is shown to be related to the different degrees of arthritis. This assertion is verified by comparing our proposed score with Sharp Van der Heijde score, confirming that the lower our score is the more advanced is the patient affection. |
|
|
Address |
Barcelona; February 2013 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
SciTePress |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
800 |
Expedition |
|
Conference |
BIODEVICES |
|
|
Notes |
IAM;MV; 600.057; 600.054;SIAI |
Approved |
no |
|
|
Call Number |
IAM @ iam @ NGV2013 |
Serial |
2196 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Petia Radeva; Fernando Vilariño |
|
|
Title |
Anisotropic Contour Completion |
Type |
Conference Article |
|
Year |
2003 |
Publication |
Proceedings of the IEEE International Conference on Image Processing |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
I-869 |
|
|
Keywords |
|
|
|
Abstract |
In this paper we introduce a novel application of the diffusion tensor for anisotropic image processing. The Anisotropic Contour Completion (ACC) we suggest consists in extending the characteristic function of the open curve by means of a degenerated diffusion tensor that prevents any diffusion in the normal direction. We show that ACC is equivalent to a dilation with a continuous elliptic structural element that takes into account the local orientation of the contours to be closed. Experiments on contours extracted from real images show that ACC produces shapes able to adapt to any curve in an active contour framework. 1. |
|
|
Address |
Barcelona, Spain |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Barcelona, Spain |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
0-7803-7751-6 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ICIP |
|
|
Notes |
IAM;MV;MILAB;SIAI |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GRV2003 |
Serial |
1539 |
|
Permanent link to this record |
|
|
|
|
Author |
J. Mauri; Eduard Fernandez-Nofrerias; B. Garcia del Blanco; E. Iraculis; J.A. Gomez-Hospital; J. Comin; M.A. Sanchez Corral; F. Jara; A. Cequier; E. Esplugas; Debora Gil; J. Saludes; Petia Radeva; Ricardo Toledo; Juan J.Villanueva |
|
|
Title |
Moviment del vas en l anàlisi d imatges d ecografia intracoronària: un model matemàtic |
Type |
Conference Article |
|
Year |
2000 |
Publication |
Congrés de la Societat Catalana de Cardiologia. |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;RV;ISE;MILAB;ADAS |
Approved |
no |
|
|
Call Number |
IAM @ iam @ MNG2000 |
Serial |
1621 |
|
Permanent link to this record |
|
|
|
|
Author |
J. Mauri; Eduard Fernandez-Nofrerias; J. Comin; B. Garcia del Blanco; E. Iraculis; J.A. Gomez-Hospital; P. Valdovinos; F. Jara; A. Cequier; E. Esplugas; Oriol Pujol; Cristina Cañero; Debora Gil; Petia Radeva; Ricardo Toledo |
|
|
Title |
Avaluació del Conjunt Stent/Artèria mitjançant ecografia intracoronària: lentorn informàtic |
Type |
Conference Article |
|
Year |
2000 |
Publication |
Congrés de la Societat Catalana de Cardiologia. |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;RV;MILAB;ADAS; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ MNC2000 |
Serial |
1622 |
|
Permanent link to this record |
|
|
|
|
Author |
Cristina Cañero; Petia Radeva; Oriol Pujol; Ricardo Toledo; Debora Gil; J. Saludes; Juan J. Villanueva; B. Garcia del Blanco; J. Mauri; E. Fernandez-Nofrerias; J.A. Gomez-Hospital; E. Iraculis; J. Comin; C. Quiles; F. Jara; A. Cequier; E. Esplugas |
|
|
Title |
Optimal Stent Implantation: Three-dimensional Evaluation of the Mutual Position of Stent and Vessel via Intracoronary Ecography |
Type |
Conference Article |
|
Year |
1999 |
Publication |
Proceedings of International Conference on Computer in Cardiology (CIC´99) |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
We present a new automatic technique to visualize and quantify the mutual position between the stent and the vessel wall by considering their three-dimensional reconstruction. Two deformable generalized cylinders adapt to the image features in all IVUS planes corresponding to the vessel wall and the stent in order to reconstruct the boundaries of the stent and the vessel in space. The image features that characterize the stent and the vessel wall are determined in terms of edge and ridge image detectors taking into account the gray level of the image pixels. We show that the 30 reconstruction by deformable cylinders is accurate and robust due to the spatial data coherence in the considered volumetric IVUS image. The main clinic utility of the stent and vessel reconstruction by deformable’ cylinders consists of its possibility to visualize and to assess the optimal stent introduction. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB; RV; IAM; ADAS; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ CRP1999a |
Serial |
1491 |
|
Permanent link to this record |
|
|
|
|
Author |
Petia Radeva; Joan Serrat; Enric Marti |
|
|
Title |
A snake for model-based segmentation |
Type |
Conference Article |
|
Year |
1995 |
Publication |
Proc. Conf. Fifth Int Computer Vision |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
816-821 |
|
|
Keywords |
snakes; elastic matching; model-based segmenta tion |
|
|
Abstract |
Despite the promising results of numerous applications, the hitherto proposed snake techniques share some common problems: snake attraction by spurious edge points, snake degeneration (shrinking and attening), convergence and stability of the deformation process, snake initialization and local determination of the parameters of elasticity. We argue here that these problems can be solved only when all the snake aspects are considered. The snakes proposed here implement a new potential eld and external force in order to provide a deformation convergence, attraction by both near and far edges as well as snake behaviour selective according to the edge orientation. Furthermore, we conclude that in the case of model-based seg mentation, the internal force should include structural information about the expected snake shape. Experiments using this kind of snakes for segmenting bones in complex hand radiographs show a signicant improvement. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB;ADAS;IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RSM1995 |
Serial |
1634 |
|
Permanent link to this record |