|
Records |
Links |
|
Author |
Aura Hernandez-Sabate; David Rotger; Debora Gil |
|
|
Title |
Image-based ECG sampling of IVUS sequences |
Type |
Conference Article |
|
Year |
2008 |
Publication |
Proc. IEEE Ultrasonics Symp. IUS 2008 |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
1330-1333 |
|
|
Keywords |
Longitudinal Motion; Image-based ECG-gating; Fourier analysis |
|
|
Abstract |
Longitudinal motion artifacts in IntraVascular UltraSound (IVUS) sequences hinders a properly 3D reconstruction and vessel measurements. Most of current techniques base on the ECG signal to obtain a gated pullback without the longitudinal artifact by using a specific hardware or the ECG signal itself. The potential of IVUS images processing for phase retrieval still remains little explored. In this paper, we present a fast forward image-based algorithm to approach ECG sampling. Inspired on the fact that maximum and minimum lumen areas are related to end-systole and end-diastole, our cardiac phase retrieval is based on the analysis of tissue density of mass along the sequence. The comparison between automatic and manual phase retrieval (0.07 ± 0.07 mm. of error) encourages a deep validation contrasting with ECG signals. |
|
|
Address |
Beijing (China) |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ HRG2008 |
Serial |
1553 |
|
Permanent link to this record |
|
|
|
|
Author |
Aura Hernandez-Sabate; Debora Gil; Albert Teis |
|
|
Title |
How Do Conservation Laws Define a Motion Suppression Score in In-Vivo Ivus Sequences? |
Type |
Conference Article |
|
Year |
2007 |
Publication |
Proc. IEEE Ultrasonics Symp |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
2231-2234 |
|
|
Keywords |
validation standards; IVUS motion compensation; conservation laws. |
|
|
Abstract |
Evaluation of arterial tissue biomechanics for diagnosis and treatment of cardiovascular diseases is an active research field in the biomedical imaging processing area. IntraVascular UltraSound (IVUS) is a unique tool for such assessment since it reflects tissue morphology and deformation. A proper quantification and visualization of both properties is hindered by vessel structures misalignments introduced by cardiac dynamics. This has encouraged development of IVUS motion compensation techniques. However, there is a lack of an objective evaluation of motion reduction ensuring a reliable clinical application This work reports a novel score, the Conservation of Density Rate (CDR), for validation of motion compensation in in-vivo pullbacks. Synthetic experiments validate the proposed score as measure of motion parameters accuracy; while results in in vivo pullbacks show its reliability in clinical cases. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ HTG2007 |
Serial |
1550 |
|
Permanent link to this record |
|
|
|
|
Author |
David Roche; Debora Gil; Jesus Giraldo |
|
|
Title |
Detecting loss of diversity for an efficient termination of EAs |
Type |
Conference Article |
|
Year |
2013 |
Publication |
15th International Symposium on Symbolic and Numeric Algorithms for Scientific Computing |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
561 - 566 |
|
|
Keywords |
EA termination; EA population diversity; EA steady state |
|
|
Abstract |
Termination of Evolutionary Algorithms (EA) at its steady state so that useless iterations are not performed is a main point for its efficient application to black-box problems. Many EA algorithms evolve while there is still diversity in their population and, thus, they could be terminated by analyzing the behavior some measures of EA population diversity. This paper presents a numeric approximation to steady states that can be used to detect the moment EA population has lost its diversity for EA termination. Our condition has been applied to 3 EA paradigms based on diversity and a selection of functions
covering the properties most relevant for EA convergence.
Experiments show that our condition works regardless of the search space dimension and function landscape. |
|
|
Address |
Timisoara; Rumania; |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-1-4799-3035-7 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
SYNASC |
|
|
Notes |
IAM; 600.044; 600.060; 605.203 |
Approved |
no |
|
|
Call Number |
Admin @ si @ RGG2013c |
Serial |
2299 |
|
Permanent link to this record |
|
|
|
|
Author |
Sergio Vera; Miguel Angel Gonzalez Ballester; Debora Gil |
|
|
Title |
A medial map capturing the essential geometry of organs |
Type |
Conference Article |
|
Year |
2012 |
Publication |
ISBI Workshop on Open Source Medical Image Analysis software |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
1691 - 1694 |
|
|
Keywords |
Medial Surface Representation, Volume Reconstruction,Geometry , Image reconstruction , Liver , Manifolds , Shape , Surface morphology , Surface reconstruction |
|
|
Abstract |
Medial representations are powerful tools for describing and parameterizing the volumetric shape of anatomical structures. Accurate computation of one pixel wide medial surfaces is mandatory. Those surfaces must represent faithfully the geometry of the volume. Although morphological methods produce excellent results in 2D, their complexity and quality drops across dimensions, due to a more complex description of pixel neighborhoods. This paper introduces a continuous operator for accurate and efficient computation of medial structures of arbitrary dimension. Our experiments show its higher performance for medical imaging applications in terms of simplicity of medial structures and capability for reconstructing the anatomical volume |
|
|
Address |
Barcelona,Spain |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
IEEE |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1945-7928 |
ISBN |
978-1-4577-1857-1 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ISBI |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ VGG2012a |
Serial |
1989 |
|
Permanent link to this record |
|
|
|
|
Author |
Jaume Garcia; Francesc Carreras; Sandra Pujades; Debora Gil |
|
|
Title |
Regional motion patterns for the Left Ventricle function assessment |
Type |
Conference Article |
|
Year |
2008 |
Publication |
Proc. 19th Int. Conf. Pattern Recognition ICPR 2008 |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
1-4 |
|
|
Keywords |
|
|
|
Abstract |
Regional scores (e.g. strain, perfusion) of the Left Ventricle (LV) functionality are playing an increasing role in the diagnosis of cardiac diseases. A main limitation is the lack of normality models for complementary scores oriented to assessment of the LV integrity. This paper introduces an original framework based on a parametrization of the LV domain, which allows comparison across subjects of local physiological measures of different nature. We compute regional normality patterns in a feature space characterizing the LV function. We show the consistency of the model for the regional motion on healthy and hypokinetic pathological cases |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GCP2008 |
Serial |
1510 |
|
Permanent link to this record |
|
|
|
|
Author |
Jaume Garcia; Debora Gil; A.Bajo; M.J.Ledesma-Carbayo; C.SantaMarta |
|
|
Title |
Influence of the temporal resolution on the quantification of displacement fields in cardiac magnetic resonance tagged images |
Type |
Conference Article |
|
Year |
2008 |
Publication |
Proc. Computers in Cardiology |
Abbreviated Journal |
|
|
|
Volume |
35 |
Issue |
|
Pages |
785-788 |
|
|
Keywords |
|
|
|
Abstract |
It is difficult to acquire tagged cardiac MR images with a high temporal and spatial resolution using clinical MR scanners. However, if such images are used for quantifying scores based on motion, it is essential a resolution as high as possible. This paper explores the influence of the temporal resolution of a tagged series on the quantification of myocardial dynamic parameters. To such purpose we have designed a SPAMM (Spatial Modulation of Magnetization) sequence allowing acquisition of sequences at simple and double temporal resolution. Sequences are processed to compute myocardial motion by an automatic technique based on the tracking of the harmonic phase of tagged images (the Harmonic Phase Flow, HPF). The results have been compared to manual tracking of myocardial tags. The error in displacement fields for double resolution sequences reduces 17%. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
Alan Murray |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GGB2008 |
Serial |
1508 |
|
Permanent link to this record |
|
|
|
|
Author |
Aura Hernandez-Sabate; Debora Gil; Petia Radeva; E.N.Nofrerias |
|
|
Title |
Anisotropic processing of image structures for adventitia detection in intravascular ultrasound images |
Type |
Conference Article |
|
Year |
2004 |
Publication |
Proc. Computers in Cardiology |
Abbreviated Journal |
|
|
|
Volume |
31 |
Issue |
|
Pages |
229-232 |
|
|
Keywords |
|
|
|
Abstract |
The adventitia layer appears as a weak edge in IVUS images with a non-uniform grey level, which difficulties its detection. In order to enhance edges, we apply an anisotropic filter that homogenizes the grey level along the image significant structures (ridges, valleys and edges). A standard edge detector applied to the filtered image yields a set of candidate points prone to be unconnected. The final model is obtained by interpolating the former line segments along the tangent direction to the level curves of the filtered image with an anisotropic contour closing technique based on functional extension principles |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Chicago (USA) |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ HGR2004 |
Serial |
1555 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Agnes Borras; Sergio Vera; Miguel Angel Gonzalez Ballester |
|
|
Title |
A Validation Benchmark for Assessment of Medial Surface Quality for Medical Applications |
Type |
Conference Article |
|
Year |
2013 |
Publication |
9th International Conference on Computer Vision Systems |
Abbreviated Journal |
|
|
|
Volume |
7963 |
Issue |
|
Pages |
334-343 |
|
|
Keywords |
Medial Surfaces; Shape Representation; Medical Applications; Performance Evaluation |
|
|
Abstract |
Confident use of medial surfaces in medical decision support systems requires evaluating their quality for detecting pathological deformations and describing anatomical volumes. Validation in the medical imaging field is a challenging task mainly due to the difficulties for getting consensual ground truth. In this paper we propose a validation benchmark for assessing medial surfaces in the context of medical applications. Our benchmark includes a home-made database of synthetic medial surfaces and volumes and specific scores for evaluating surface accuracy, its stability against volume deformations and its capabilities for accurate reconstruction of anatomical volumes. |
|
|
Address |
Sant Petersburg; Russia; July 2013 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Berlin Heidelberg |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-642-39401-0 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ICVS |
|
|
Notes |
IAM; 600.044; 600.060 |
Approved |
no |
|
|
Call Number |
Admin @ si @ GBV2013 |
Serial |
2300 |
|
Permanent link to this record |
|
|
|
|
Author |
Ferran Poveda; Debora Gil;Enric Marti |
|
|
Title |
Multi-resolution DT-MRI cardiac tractography |
Type |
Conference Article |
|
Year |
2012 |
Publication |
Statistical Atlases And Computational Models Of The Heart: Imaging and Modelling Challenges |
Abbreviated Journal |
|
|
|
Volume |
7746 |
Issue |
|
Pages |
270-277 |
|
|
Keywords |
|
|
|
Abstract |
Even using objective measures from DT-MRI no consensus about myocardial architecture has been achieved so far. Streamlining provides good reconstructions at low level of detail, but falls short to give global abstract interpretations. In this paper, we present a multi-resolution methodology that is able to produce simplified representations of cardiac architecture. Our approach produces a reduced set of tracts that are representative of the main geometric features of myocardial anatomical structure. Experiments show that fiber geometry is preserved along reductions, which validates the simplified model for interpretation of cardiac architecture. |
|
|
Address |
Nice, France |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Berlin Heidelberg |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-642-36960-5 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
STACOM |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ PGM2012 |
Serial |
1986 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil;Agnes Borras;Ruth Aris;Mariano Vazquez;Pierre Lafortune; Guillame Houzeaux |
|
|
Title |
What a difference in biomechanics cardiac fiber makes |
Type |
Conference Article |
|
Year |
2012 |
Publication |
Statistical Atlases And Computational Models Of The Heart: Imaging and Modelling Challenges |
Abbreviated Journal |
|
|
|
Volume |
7746 |
Issue |
|
Pages |
253-260 |
|
|
Keywords |
|
|
|
Abstract |
Computational simulations of the heart are a powerful tool for a comprehensive understanding of cardiac function and its intrinsic relationship with its muscular architecture. Cardiac biomechanical models require a vector field representing the orientation of cardiac fibers. A wrong orientation of the fibers can lead to a
non-realistic simulation of the heart functionality. In this paper we explore the impact of the fiber information on the simulated biomechanics of cardiac muscular anatomy. We have used the John Hopkins database to perform a biomechanical simulation using both a synthetic benchmark fiber distribution and the data obtained experimentally from DTI. Results illustrate how differences in fiber orientation affect heart deformation along cardiac cycle. |
|
|
Address |
Nice, France |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Berlin Heidelberg |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-642-36960-5 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
STACOM |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GBA2012 |
Serial |
1987 |
|
Permanent link to this record |