|
David Roche, Debora Gil, & Jesus Giraldo. (2013). "Detecting loss of diversity for an efficient termination of EAs " In 15th International Symposium on Symbolic and Numeric Algorithms for Scientific Computing (pp. 561–566).
Abstract: Termination of Evolutionary Algorithms (EA) at its steady state so that useless iterations are not performed is a main point for its efficient application to black-box problems. Many EA algorithms evolve while there is still diversity in their population and, thus, they could be terminated by analyzing the behavior some measures of EA population diversity. This paper presents a numeric approximation to steady states that can be used to detect the moment EA population has lost its diversity for EA termination. Our condition has been applied to 3 EA paradigms based on diversity and a selection of functions
covering the properties most relevant for EA convergence.
Experiments show that our condition works regardless of the search space dimension and function landscape.
Keywords: EA termination; EA population diversity; EA steady state
|
|
|
Patricia Marquez, Debora Gil, & Aura Hernandez-Sabate. (2013). "Evaluation of the Capabilities of Confidence Measures for Assessing Optical Flow Quality " In ICCV Workshop on Computer Vision in Vehicle Technology: From Earth to Mars (pp. 624–631).
Abstract: Assessing Optical Flow (OF) quality is essential for its further use in reliable decision support systems. The absence of ground truth in such situations leads to the computation of OF Confidence Measures (CM) obtained from either input or output data. A fair comparison across the capabilities of the different CM for bounding OF error is required in order to choose the best OF-CM pair for discarding points where OF computation is not reliable. This paper presents a statistical probabilistic framework for assessing the quality of a given CM. Our quality measure is given in terms of the percentage of pixels whose OF error bound can not be determined by CM values. We also provide statistical tools for the computation of CM values that ensures a given accuracy of the flow field.
|
|
|
Debora Gil, Oriol Rodriguez, Josepa Mauri, & Petia Radeva. (2006)." Statistical descriptors of the Myocardial perfusion in angiographic images" In Proc. Computers in Cardiology (pp. 677–680).
Abstract: Restoration of coronary flow after primary percutaneous coronary intervention in acute myocardial infarction does not always correlate with adequate myocardial perfusion. Recently, coronary angiography has been used to assess microcirculation integrity (Myocardial BlushAnalysis, MBA). Although MBA correlates with patient prognosis there are few image processing methods addressing objective perfusion quantification. The goal of this work is to develop statistical descriptors of the myocardial dyeing pattern allowing objective assessment of myocardial perfusion. Experiments on healthy right coronary arteries show that our approach allows reliable measurements without any specific image acquisition protocol.
Keywords: Anisotropic processing; intravascular ultrasound (IVUS); vessel border segmentation; vessel structure classification.
|
|
|
Aura Hernandez-Sabate, Debora Gil, Josefina Mauri, & Petia Radeva. (2006). "Reducing cardiac motion in IVUS sequences " In Proceeding of Computers in Cardiology (Vol. 33, pp. 685–688).
Abstract: Cardiac vessel displacement is a main artifact in IVUS sequences. It hinders visualization of the main structures in an appropriate orientation and alignment and affects extracting vessel measurements. In this paper, we present a novel approach for image sequence alignment based on spectral analysis, which removes rigid dynamics, preserving at the same time the vessel geometry. First, we suppress the translation by taking, for each frame, the center of mass of the image as origin of coordinates. In polar coordinates with such point as origin, the rotation appears as a horizontal displacement. The translation induces a phase shift in the Fourier coefficients of two consecutive polar images. We estimate the phase by adjusting a regression plane to the phases of the principal frequencies. Experiments show that the presented strategy suppress cardiac motion regardless of the acquisition device. 1.
|
|
|
Antoni Gurgui, Debora Gil, & Enric Marti. (2015). "Laplacian Unitary Domain for Texture Morphing " In Proceedings of the 10th International Conference on Computer Vision Theory and Applications VISIGRAPP2015 (Vol. 1, pp. 693–699). SciTePress.
Abstract: Deformation of expressive textures is the gateway to realistic computer synthesis of expressions. By their good mathematical properties and flexible formulation on irregular meshes, most texture mappings rely on solutions to the Laplacian in the cartesian space. In the context of facial expression morphing, this approximation can be seen from the opposite point of view by neglecting the metric. In this paper, we use the properties of the Laplacian in manifolds to present a novel approach to warping expressive facial images in order to generate a morphing between them.
Keywords: Facial; metamorphosis;LaplacianMorphing
|
|
|
Jaume Garcia, Debora Gil, A.Bajo, M.J.Ledesma-Carbayo, & C.SantaMarta. (2008). "Influence of the temporal resolution on the quantification of displacement fields in cardiac magnetic resonance tagged images " In Alan Murray (Ed.), Proc. Computers in Cardiology (Vol. 35, pp. 785–788).
Abstract: It is difficult to acquire tagged cardiac MR images with a high temporal and spatial resolution using clinical MR scanners. However, if such images are used for quantifying scores based on motion, it is essential a resolution as high as possible. This paper explores the influence of the temporal resolution of a tagged series on the quantification of myocardial dynamic parameters. To such purpose we have designed a SPAMM (Spatial Modulation of Magnetization) sequence allowing acquisition of sequences at simple and double temporal resolution. Sequences are processed to compute myocardial motion by an automatic technique based on the tracking of the harmonic phase of tagged images (the Harmonic Phase Flow, HPF). The results have been compared to manual tracking of myocardial tags. The error in displacement fields for double resolution sequences reduces 17%.
|
|
|
Petia Radeva, Joan Serrat, & Enric Marti. (1995). "A snake for model-based segmentation " In Proc. Conf. Fifth Int Computer Vision (pp. 816–821).
Abstract: Despite the promising results of numerous applications, the hitherto proposed snake techniques share some common problems: snake attraction by spurious edge points, snake degeneration (shrinking and attening), convergence and stability of the deformation process, snake initialization and local determination of the parameters of elasticity. We argue here that these problems can be solved only when all the snake aspects are considered. The snakes proposed here implement a new potential eld and external force in order to provide a deformation convergence, attraction by both near and far edges as well as snake behaviour selective according to the edge orientation. Furthermore, we conclude that in the case of model-based seg mentation, the internal force should include structural information about the expected snake shape. Experiments using this kind of snakes for segmenting bones in complex hand radiographs show a signicant improvement.
Keywords: snakes; elastic matching; model-based segmenta tion
|
|
|
Oriol Rodriguez-Leon, Eduard Fernandez-Nofrerias, Josefina Mauri, Vicente del Valle, Debora Gil, A.Barrios, et al. (2006)." Perfusion ratio: A new tool to objectively assess microcirculation perfusion after primary Percutaneous Coronary Intervention" In World Congress of Cardiology (859). Barcelona (Spain).
|
|
|
Oriol Rodriguez-Leon, Josefina Mauri, Eduard Fernandez-Nofrerias, Vicente de Valle, E.Garcia, A.Barrios, et al. (2006)." Analysis of the changes in angiography local grey-level values to determine myocardial perfusion" In World Congress of Cardiology (862). Barcelona (Spain).
|
|
|
Jaume Garcia, Debora Gil, Joel Barajas, Francesc Carreras, Sandra Pujades, & Petia Radeva. (2006). "Characterization of ventricular torsion in healthy subjects using Gabor filters and a variational framework " In Proc. Computers in Cardiology (pp. 877–880).
Abstract: In this work, we present a fully automated method for tissue deformation estimation in tagged magnetic resonance images (TMRI). Gabor filter banks, tuned independently for each left ventricle level, provide optimally filtered complex images which phase remains constant along the cardiac cycle. This fact can be thought as the brightness constancy condition required by classical optical flow (OF) methods. Pairs of these filtered sequences, together with a variational formulation are used in a second step to obtain dense continuous deformation maps that we call Harmonic Phase Flow. This method has been used to determine reference values of ventricular torsion (VT) in a set of 8 healthy volunteers. The results encourage the use of VT as a useful parameter for ventricular function assessment in clinical routine.
|
|