Josep Llados, Ernest Valveny, Gemma Sanchez, & Enric Marti. (2003). A Case Study of Pattern Recognition: Symbol Recognition in Graphic Documentsa In Proceedings of Pattern Recognition in Information Systems (pp. 1–13). ICEIS Press.
|
|
|
Petia Radeva, A.Amini, J.Huang, & Enric Marti. (1996). "Deformable B-Solids and Implicit Snakes for Localization and Tracking of SPAMM MRI-Data " In Workshop on Mathematical Methods in Biomedical Image Analysis (pp. 192–201). IEEE Computer Society.
Abstract: To date, MRI-SPAMM data from different image slices have been analyzed independently. In this paper, we propose an approach for 3D tag localization and tracking of SPAMM data by a novel deformable B-solid. The solid is defined in terms of a 3D tensor product B-spline. The isoparametric curves of the B-spline solid have special importance. These are termed implicit snakes as they deform under image forces from tag lines in different image slices. The localization and tracking of tag lines is performed under constraints of continuity and smoothness of the B-solid. The framework unifies the problems of localization, and displacement fitting and interpolation into the same procedure utilizing B-spline bases for interpolation. To track motion from boundaries and restrict image forces to the myocardium, a volumetric model is employed as a pair of coupled endocardial and epicardial B-spline surfaces. To recover deformations in the LV an energy-minimization problem is posed where both tag and ...
|
|
|
Ferran Poveda, Jaume Garcia, Enric Marti, & Debora Gil. (2010). "Validation of the myocardial architecture in DT-MRI tractography " In Medical Image Computing in Catalunya: Graduate Student Workshop (pp. 29–30). Girona (Spain).
Abstract: Deep understanding of myocardial structure may help to link form and funcion of the heart unraveling crucial knowledge for medical and surgical clinical procedures and studies. In this work we introduce two visualization techniques based on DT-MRI streamlining able to decipher interesting properties of the architectural organization of the heart.
|
|
|
Antonio Esteban Lansaque, Carles Sanchez, Agnes Borras, Marta Diez-Ferrer, Antoni Rosell, & Debora Gil. (2016). "Stable Anatomical Structure Tracking for video-bronchoscopy Navigation " In 19th International Conference on Medical Image Computing and Computer Assisted Intervention Workshops.
Abstract: Bronchoscopy allows to examine the patient airways for detection of lesions and sampling of tissues without surgery. A main drawback in lung cancer diagnosis is the diculty to check whether the exploration is following the correct path to the nodule that has to be biopsied. The most extended guidance uses uoroscopy which implies repeated radiation of clinical sta and patients. Alternatives such as virtual bronchoscopy or electromagnetic navigation are very expensive and not completely robust to blood, mocus or deformations as to be extensively used. We propose a method that extracts and tracks stable lumen regions at dierent levels of the bronchial tree. The tracked regions are stored in a tree that encodes the anatomical structure of the scene which can be useful to retrieve the path to the lesion that the clinician should follow to do the biopsy. We present a multi-expert validation of our anatomical landmark extraction in 3 intra-operative ultrathin explorations.
Keywords: Lung cancer diagnosis; video-bronchoscopy; airway lumen detection; region tracking
|
|
|
Carles Sanchez, Debora Gil, Jorge Bernal, F. Javier Sanchez, Marta Diez-Ferrer, & Antoni Rosell. (2016). "Navigation Path Retrieval from Videobronchoscopy using Bronchial Branches " In 19th International Conference on Medical Image Computing and Computer Assisted Intervention Workshops (Vol. 9401, pp. 62–70).
Abstract: Bronchoscopy biopsy can be used to diagnose lung cancer without risking complications of other interventions like transthoracic needle aspiration. During bronchoscopy, the clinician has to navigate through the bronchial tree to the target lesion. A main drawback is the difficulty to check whether the exploration is following the correct path. The usual guidance using fluoroscopy implies repeated radiation of the clinician, while alternative systems (like electromagnetic navigation) require specific equipment that increases intervention costs. We propose to compute the navigated path using anatomical landmarks extracted from the sole analysis of videobronchoscopy images. Such landmarks allow matching the current exploration to the path previously planned on a CT to indicate clinician whether the planning is being correctly followed or not. We present a feasibility study of our landmark based CT-video matching using bronchoscopic videos simulated on a virtual bronchoscopy interactive interface.
Keywords: Bronchoscopy navigation; Lumen center; Brochial branches; Navigation path; Videobronchoscopy
|
|
|
Esmitt Ramirez, Carles Sanchez, Agnes Borras, Marta Diez-Ferrer, Antoni Rosell, & Debora Gil. (2018). "Image-Based Bronchial Anatomy Codification for Biopsy Guiding in Video Bronchoscopy " In OR 2.0 Context-Aware Operating Theaters, Computer Assisted Robotic Endoscopy, Clinical Image-Based Procedures, and Skin Image Analysis (Vol. 11041).
Abstract: Bronchoscopy examinations allow biopsy of pulmonary nodules with minimum risk for the patient. Even for experienced bronchoscopists, it is difficult to guide the bronchoscope to most distal lesions and obtain an accurate diagnosis. This paper presents an image-based codification of the bronchial anatomy for bronchoscopy biopsy guiding. The 3D anatomy of each patient is codified as a binary tree with nodes representing bronchial levels and edges labeled using their position on images projecting the 3D anatomy from a set of branching points. The paths from the root to leaves provide a codification of navigation routes with spatially consistent labels according to the anatomy observes in video bronchoscopy explorations. We evaluate our labeling approach as a guiding system in terms of the number of bronchial levels correctly codified, also in the number of labels-based instructions correctly supplied, using generalized mixed models and computer-generated data. Results obtained for three independent observers prove the consistency and reproducibility of our guiding system. We trust that our codification based on viewer’s projection might be used as a foundation for the navigation process in Virtual Bronchoscopy systems.
Keywords: Biopsy guiding; Bronchoscopy; Lung biopsy; Intervention guiding; Airway codification
|
|
|
Sergio Vera, Miguel Angel Gonzalez Ballester, & Debora Gil. (2013). "Volumetric Anatomical Parameterization and Meshing for Inter-patient Liver Coordinate System Deffinition " In 16th International Conference on Medical Image Computing and Computer Assisted Intervention.
|
|
|
Mireia Sole, Joan Blanco, Debora Gil, G. Fonseka, Richard Frodsham, Oliver Valero, et al. (2017). "Is there a pattern of Chromosome territoriality along mice spermatogenesis? " In 3rd Spanish MeioNet Meeting Abstract Book (pp. 55–56).
|
|
|
David Roche, Debora Gil, & Jesus Giraldo. (2012). "Assessing agonist efficacy in an uncertain Em world " In A. Christopoulus and M. Bouvier (Ed.), 40th Keystone Symposia on mollecular and celular biology (79). Keystone Symposia.
Abstract: The operational model of agonism has been widely used for the analysis of agonist action since its formulation in 1983. The model includes the Em parameter, which is defined as the maximum response of the system. The methods for Em estimation provide Em values not significantly higher than the maximum responses achieved by full agonists. However, it has been found that that some classes of compounds as, for instance, superagonists and positive allosteric modulators can increase the full agonist maximum response, implying upper limits for Em and thereby posing doubts on the validity of Em estimates. Because of the correlation between Em and operational efficacy, τ, wrong Em estimates will yield wrong τ estimates.
In this presentation, the operational model of agonism and various methods for the simulation of allosteric modulation will be analyzed. Alternatives for curve fitting will be presented and discussed.
|
|
|
Albert Andaluz, Francesc Carreras, Cristina Santa Marta, & Debora Gil. (2012). "Myocardial torsion estimation with Tagged-MRI in the OsiriX platform " In Wiro Niessen(Erasmus MC) and Marc Modat(UCL) (Ed.), ISBI Workshop on Open Source Medical Image Analysis software. IEEE.
Abstract: Myocardial torsion (MT) plays a crucial role in the assessment of the functionality of the
left ventricle. For this purpose, the IAM group at the CVC has developed the Harmonic Phase Flow (HPF) plugin for the Osirix DICOM platform . We have validated its funcionalty on sequences acquired using different protocols and including healthy and pathological cases. Results show similar torsion trends for SPAMM acquisitions, with pathological cases introducing expected deviations from the ground truth. Finally, we provide the plugin free of charge at http://iam.cvc.uab.es
|
|