|
Gemma Sanchez, Josep Llados, & Enric Marti. (1997). "A string-based method to recognize symbols and structural textures in architectural plans " In 2nd IAPR Workshop on Graphics Recognition.
Abstract: This paper deals with the recognition of symbols and struc- tural textures in architectural plans using string matching techniques. A plan is represented by an attributed graph whose nodes represent characteristic points and whose edges represent segments. Symbols and textures can be seen as a set of regions, i.e. closed loops in the graph, with a particular arrangement. The search for a symbol involves a graph matching between the regions of a model graph and the regions of the graph representing the document. Discriminating a texture means a clus- tering of neighbouring regions of this graph. Both procedures involve a similarity measure between graph regions. A string codification is used to represent the sequence of outlining edges of a region. Thus, the simila- rity between two regions is defined in terms of the string edit distance between their boundary strings. The use of string matching allows the recognition method to work also under presence of distortion.
|
|
|
Sergio Vera, Miguel Angel Gonzalez Ballester, & Debora Gil. (2013). "Volumetric Anatomical Parameterization and Meshing for Inter-patient Liver Coordinate System Deffinition " In 16th International Conference on Medical Image Computing and Computer Assisted Intervention.
|
|
|
Carles Sanchez, Jorge Bernal, Debora Gil, & F. Javier Sanchez. (2013). "On-line lumen centre detection in gastrointestinal and respiratory endoscopy " In Klaus Miguel Angel and Drechsler Stefan and González Ballester Raj and Wesarg Cristina and Shekhar Marius George and Oyarzun Laura M. and L. Erdt (Ed.), Second International Workshop Clinical Image-Based Procedures (Vol. 8361, pp. 31–38). Springer International Publishing.
Abstract: We present in this paper a novel lumen centre detection for gastrointestinal and respiratory endoscopic images. The proposed method is based on the appearance and geometry of the lumen, which we defined as the darkest image region which centre is a hub of image gradients. Experimental results validated on the first public annotated gastro-respiratory database prove the reliability of the method for a wide range of images (with precision over 95 %).
Keywords: Lumen centre detection; Bronchoscopy; Colonoscopy
|
|
|
Antoni Gurgui, Debora Gil, & Enric Marti. (2015). "Laplacian Unitary Domain for Texture Morphing " In Proceedings of the 10th International Conference on Computer Vision Theory and Applications VISIGRAPP2015 (Vol. 1, pp. 693–699). SciTePress.
Abstract: Deformation of expressive textures is the gateway to realistic computer synthesis of expressions. By their good mathematical properties and flexible formulation on irregular meshes, most texture mappings rely on solutions to the Laplacian in the cartesian space. In the context of facial expression morphing, this approximation can be seen from the opposite point of view by neglecting the metric. In this paper, we use the properties of the Laplacian in manifolds to present a novel approach to warping expressive facial images in order to generate a morphing between them.
Keywords: Facial; metamorphosis;LaplacianMorphing
|
|
|
Mireia Sole, Joan Blanco, Debora Gil, G. Fonseka, Richard Frodsham, Oliver Valero, et al. (2017). "Is there a pattern of Chromosome territoriality along mice spermatogenesis? " In 3rd Spanish MeioNet Meeting Abstract Book (pp. 55–56).
|
|
|
Debora Gil, Aura Hernandez-Sabate, Mireia Burnat, Steven Jansen, & Jordi Martinez-Vilalta. (2009). "Structure-Preserving Smoothing of Biomedical Images " In 13th International Conference on Computer Analysis of Images and Patterns (Vol. 5702, pp. 427–434). Springer Berlin Heidelberg.
Abstract: Smoothing of biomedical images should preserve gray-level transitions between adjacent tissues, while restoring contours consistent with anatomical structures. Anisotropic diffusion operators are based on image appearance discontinuities (either local or contextual) and might fail at weak inter-tissue transitions. Meanwhile, the output of block-wise and morphological operations is prone to present a block structure due to the shape and size of the considered pixel neighborhood. In this contribution, we use differential geometry concepts to define a diffusion operator that restricts to image consistent level-sets. In this manner, the final state is a non-uniform intensity image presenting homogeneous inter-tissue transitions along anatomical structures, while smoothing intra-structure texture. Experiments on different types of medical images (magnetic resonance, computerized tomography) illustrate its benefit on a further process (such as segmentation) of images.
Keywords: non-linear smoothing; differential geometry; anatomical structures segmentation; cardiac magnetic resonance; computerized tomography.
|
|
|
Gloria Fernandez Esparrach, Jorge Bernal, Cristina Rodriguez de Miguel, Debora Gil, Fernando Vilariño, Henry Cordova, et al. (2016)." Utilidad de la visión por computador para la localización de pólipos pequeños y planos" In XIX Reunión Nacional de la Asociación Española de Gastroenterología, Gastroenterology Hepatology (Vol. 39, 94).
|
|
|
Jaume Garcia, Joel Barajas, Francesc Carreras, Sandra Pujades, & Petia Radeva. (2005). "An intuitive validation technique to compare local versus global tagged MRI analysis " In Computers In Cardiology (Vol. 32, 29–32).
Abstract: Myocardium appears as a uniform tissue that seen in convectional Magnetic Resonance Images (MRI) shows just the contractile part of its movement. MR Tagging is a unique imaging technique that prints a grid over the tissue which moves according to the underlying movement of the myocardium revealing the true deformation of the cardiac muscle. Optical flow techniques based on spectral information estimate tissue displacement by analyzing information encoded in the phase maps which can be obtained using, local (Gabor) and global (HARP) methods. In this paper we compare both in synthetic and real Tagged MR sequences. We conclude that local method is slightly more accurate than the global one. On the other hand, global method is more efficient as it is much faster and less parameters have to be taken into account
|
|
|
David Roche, Debora Gil, & Jesus Giraldo. (2011). "An inference model for analyzing termination conditions of Evolutionary Algorithms " In 14th Congrès Català en Intel·ligencia Artificial (pp. 216–225).
Abstract: In real-world problems, it is mandatory to design a termination condition for Evolutionary Algorithms (EAs) ensuring stabilization close to the unknown optimum. Distribution-based quantities are good candidates as far as suitable parameters are used. A main limitation for application to real-world problems is that such parameters strongly depend on the topology of the objective function, as well as, the EA paradigm used.
We claim that the termination problem would be fully solved if we had a model measuring to what extent a distribution-based quantity asymptotically behaves like the solution accuracy. We present a regression-prediction model that relates any two given quantities and reports if they can be statistically swapped as termination conditions. Our framework is applied to two issues. First, exploring if the parameters involved in the computation of distribution-based quantities influence their asymptotic behavior. Second, to what extent existing distribution-based quantities can be asymptotically exchanged for the accuracy of the EA solution.
Keywords: Evolutionary Computation Convergence, Termination Conditions, Statistical Inference
|
|
|
Patricia Marquez, Debora Gil, R.Mester, & Aura Hernandez-Sabate. (2014). "Local Analysis of Confidence Measures for Optical Flow Quality Evaluation " In 9th International Conference on Computer Vision Theory and Applications (Vol. 3, pp. 450–457).
Abstract: Optical Flow (OF) techniques facing the complexity of real sequences have been developed in the last years. Even using the most appropriate technique for our specific problem, at some points the output flow might fail to achieve the minimum error required for the system. Confidence measures computed from either input data or OF output should discard those points where OF is not accurate enough for its further use. It follows that evaluating the capabilities of a confidence measure for bounding OF error is as important as the definition
itself. In this paper we analyze different confidence measures and point out their advantages and limitations for their use in real world settings. We also explore the agreement with current tools for their evaluation of confidence measures performance.
Keywords: Optical Flow; Confidence Measure; Performance Evaluation.
|
|