|
Debora Gil, Jose Maria-Carazo, & Roberto Marabini. (2006). "On the nature of 2D crystal unbending " . Journal of Structural Biology, 156(3), 546–555.
Abstract: Crystal unbending, the process that aims to recover a perfect crystal from experimental data, is one of the more important steps in electron crystallography image processing. The unbending process involves three steps: estimation of the unit cell displacements from their ideal positions, extension of the deformation field to the whole image and transformation of the image in order to recover an ideal crystal. In this work, we present a systematic analysis of the second step oriented to address two issues. First, whether the unit cells remain undistorted and only the distance between them should be changed (rigid case) or should be modified with the same deformation suffered by the whole crystal (elastic case). Second, the performance of different extension algorithms (interpolation versus approximation) is explored. Our experiments show that there is no difference between elastic and rigid cases or among the extension algorithms. This implies that the deformation fields are constant over large areas. Furthermore, our results indicate that the main source of error is the transformation of the crystal image.
Keywords: Electron microscopy
|
|
|
Aura Hernandez-Sabate. (2009). "Exploring Arterial Dynamics and Structures in IntraVascular Ultrasound Sequences " (Debora Gil, Ed.). Ph.D. thesis, Ediciones Graficas Rey, .
Abstract: Cardiovascular diseases are a leading cause of death in developed countries. Most of them are caused by arterial (specially coronary) diseases, mainly caused by plaque accumulation. Such pathology narrows blood flow (stenosis) and affects artery bio- mechanical elastic properties (atherosclerosis). In the last decades, IntraVascular UltraSound (IVUS) has become a usual imaging technique for the diagnosis and follow up of arterial diseases. IVUS is a catheter-based imaging technique which shows a sequence of cross sections of the artery under study. Inspection of a single image gives information about the percentage of stenosis. Meanwhile, inspection of longitudinal views provides information about artery bio-mechanical properties, which can prevent a fatal outcome of the cardiovascular disease. On one hand, dynamics of arteries (due to heart pumping among others) is a major artifact for exploring tissue bio-mechanical properties. On the other one, manual stenosis measurements require a manual tracing of vessel borders, which is a time-consuming task and might suffer from inter-observer variations. This PhD thesis proposes several image processing tools for exploring vessel dy- namics and structures. We present a physics-based model to extract, analyze and correct vessel in-plane rigid dynamics and to retrieve cardiac phase. Furthermore, we introduce a deterministic-statistical method for automatic vessel borders detection. In particular, we address adventitia layer segmentation. An accurate validation pro- tocol to ensure reliable clinical applicability of the methods is a crucial step in any proposal of an algorithm. In this thesis we take special care in designing a valida- tion protocol for each approach proposed and we contribute to the in vivo dynamics validation with a quantitative and objective score to measure the amount of motion suppressed.
|
|
|
Aura Hernandez-Sabate. (2005). "Automatic adventitia segmentation in IntraVascular UltraSound images ". Master's thesis, , 08193 Bellaterra, Barcelona (Spain).
Abstract: A usual tool in cardiac disease diagnosis is vessel plaque assessment by analysis of IVUS sequences. Manual detection of lumen-intima, intima-media and media-adventitia vessel borders is the main activity of physicians in the process of plaque quantification. Large variety in vessel border descriptors, as well as, shades, artifacts and blurred response due to ultrasound physical properties troubles automated media-adventitia segmentation. This experimental work presents a solution to such a complex problem. The process blends advanced anisotropic filtering operators and statistic classification techniques, achieving an efficient vessel border modelling strategy. First of all, we introduce the theoretic base of the method. After that, we show the steps of the algorithm, validating the method with statistics that show that the media-adventitia border detection achieves an accuracy in the range of inter-observer variability regardless of plaque nature, vessel geometry and incomplete vessel borders. Finally, we present a little Matlab application to the automatic media-adventitia border.
|
|
|
Aura Hernandez-Sabate, Monica Mitiko, Sergio Shiguemi, & Debora Gil. (2010). "A validation protocol for assessing cardiac phase retrieval in IntraVascular UltraSound " In Computing in Cardiology (Vol. 37, pp. 899–902). IEEE.
Abstract: A good reliable approach to cardiac triggering is of utmost importance in obtaining accurate quantitative results of atherosclerotic plaque burden from the analysis of IntraVascular UltraSound. Although, in the last years, there has been an increase in research of methods for retrospective gating, there is no general consensus in a validation protocol. Many methods are based on quality assessment of longitudinal cuts appearance and those reporting quantitative numbers do not follow a standard protocol. Such heterogeneity in validation protocols makes faithful comparison across methods a difficult task. We propose a validation protocol based on the variability of the retrieved cardiac phase and explore the capability of several quality measures for quantifying such variability. An ideal detector, suitable for its application in clinical practice, should produce stable phases. That is, it should always sample the same cardiac cycle fraction. In this context, one should measure the variability (variance) of a candidate sampling with respect a ground truth (reference) sampling, since the variance would indicate how spread we are aiming a target. In order to quantify the deviation between the sampling and the ground truth, we have considered two quality scores reported in the literature: signed distance to the closest reference sample and distance to the right of each reference sample. We have also considered the residuals of the regression line of reference against candidate sampling. The performance of the measures has been explored on a set of synthetic samplings covering different cardiac cycle fractions and variabilities. From our simulations, we conclude that the metrics related to distances are sensitive to the shift considered while the residuals are robust against fraction and variabilities as far as one can establish a pair-wise correspondence between candidate and reference. We will further investigate the impact of false positive and negative detections in experimental data.
|
|
|
Patricia Marquez. (2010). "Conditions Ensuring Accuracy of Local Optical Flow Schemes " (Vol. 157). Master's thesis, , Bellaterra 08193, Barcelona, Spain.
Abstract: Accurate computation of optical flow is a key-point in many image processing fields. Detection of anomalous and unpredicted agents (such as pedestrians, bikers or cars) in urban scenes or pathology discrimination in medical imaging sequences, to mention just a two. The above kinds sequences present two main difficulties for standard optical flow techniques. On one hand, variability in acquisition conditions (illuminance, medical imaging modality, ...) force an alterantive representation for images fulfilling the britghtness constancy constrain. On the hand, current variational schemes produce oversmoothed fields unable to properly model discontinuous behaviours such as collisions or functionless pathological areas. This master project explores the abilities and limitations of local and global optical flow approaches. The master student will put especial emphasis in the theoretical grounds behind in order to design a variational framework combining the theoretical advantages of the considered techniques. In particular an optical flow based on Gabor phase tracking (developed in the group for medical imaging) will be generalized to urban scenes.
|
|
|
Enric Marti. (1996)." Análisis de elementos gráficos en documentos" . CVC UAB: Computer Vision Centre.
Abstract: En este texto se presenta un estudio sobre las t’ecnicas y aplicaciones de an’alisis de documentos, y más concretamente abordando la problem’atica del an’alisis de de entidades gr’aficas. El ’area de an’alisis de documentos tiene como objetivo la interpretaci’on de documentos impresos sobre papel por m’etodos computacionales, para obtener una descripci’on con un alto nivel de abstracci’on, que permita su posterior tratamiento y archivo por m’etodos inform’aticos. Este objetivo, junto a los trabajos realizados hasta el momento, le otorgan a esta ’area un amplio ’ambito de aplicaciones para la manipulaci’on y archivo de documentos sobre papel, que puede llegar a significar un salto cualitativo importante (del papel al disco ’optico) en el uso de soportes de informaci’on, debido a las importantes prestaciones de acceso y capacidad de archivo que suponen los medios inform’aticos. Generalmente los documentos son introducidos en los sistemas de an’alisis de documentos mediante scanner, obt...
|
|
|
Enric Marti, G.Estape, & S.Fernandez. (2008)." Bluestar: Diseño e implementación de una aplicación para la visualización interactiva en 3D de funciones reales como herramienta de aprendizaje" . Lleida.
|
|
|
Enric Marti, S.Fernandez, & G.Estape. (2007)." BlueStar: implementació d’una aplicació per a la visualització 3D de funcions reals, com a eina d’aprenentatge" . Bellaterra (Spain).
|
|
|
Maurizio Mencuccini, Jordi Martinez-Vilalta, Josep Piñol, Lasse Loepfe, Mireia Burnat, Xavier Alvarez, et al. (2010). "A quantitative and statistically robust method for the determination of xylem conduit spatial distribution " . American Journal of Botany, 97(8), 1247–1259.
Abstract: Premise of the study: Because of their limited length, xylem conduits need to connect to each other to maintain water transport from roots to leaves. Conduit spatial distribution in a cross section plays an important role in aiding this connectivity. While indices of conduit spatial distribution already exist, they are not well defined statistically. * Methods: We used point pattern analysis to derive new spatial indices. One hundred and five cross-sectional images from different species were transformed into binary images. The resulting point patterns, based on the locations of the conduit centers-of-area, were analyzed to determine whether they departed from randomness. Conduit distribution was then modeled using a spatially explicit stochastic model. * Key results: The presence of conduit randomness, uniformity, or aggregation depended on the spatial scale of the analysis. The large majority of the images showed patterns significantly different from randomness at least at one spatial scale. A strong phylogenetic signal was detected in the spatial variables. * Conclusions: Conduit spatial arrangement has been largely conserved during evolution, especially at small spatial scales. Species in which conduits were aggregated in clusters had a lower conduit density compared to those with uniform distribution. Statistically sound spatial indices must be employed as an aid in the characterization of distributional patterns across species and in models of xylem water transport. Point pattern analysis is a very useful tool in identifying spatial patterns.
Keywords: Geyer; hydraulic conductivity; point pattern analysis; Ripley; Spatstat; vessel clusters; xylem anatomy; xylem network
|
|
|
Ferran Poveda. (2009). "Visualització i interpretació tridimensional de l’arquitectura de les fibres musculars del miocardi ". Master's thesis, , 08193 Bellaterra, Barcelona (Spain).
|
|