|
Jorge Bernal, F. Javier Sanchez, Gloria Fernandez Esparrach, Debora Gil, Cristina Rodriguez de Miguel, & Fernando Vilariño. (2015). "WM-DOVA Maps for Accurate Polyp Highlighting in Colonoscopy: Validation vs. Saliency Maps from Physicians " . Computerized Medical Imaging and Graphics, 43, 99–111.
Abstract: We introduce in this paper a novel polyp localization method for colonoscopy videos. Our method is based on a model of appearance for polyps which defines polyp boundaries in terms of valley information. We propose the integration of valley information in a robust way fostering complete, concave and continuous boundaries typically associated to polyps. This integration is done by using a window of radial sectors which accumulate valley information to create WMDOVA1 energy maps related with the likelihood of polyp presence. We perform a double validation of our maps, which include the introduction of two new databases, including the first, up to our knowledge, fully annotated database with clinical metadata associated. First we assess that the highest value corresponds with the location of the polyp in the image. Second, we show that WM-DOVA energy maps can be comparable with saliency maps obtained from physicians' fixations obtained via an eye-tracker. Finally, we prove that our method outperforms state-of-the-art computational saliency results. Our method shows good performance, particularly for small polyps which are reported to be the main sources of polyp miss-rate, which indicates the potential applicability of our method in clinical practice.
Keywords: Polyp localization; Energy Maps; Colonoscopy; Saliency; Valley detection
|
|
|
Patricia Marquez, Debora Gil, Aura Hernandez-Sabate, & Daniel Kondermann. (2013). "When Is A Confidence Measure Good Enough? " In 9th International Conference on Computer Vision Systems (Vol. 7963, pp. 344–353). Springer Link.
Abstract: Confidence estimation has recently become a hot topic in image processing and computer vision.Yet, several definitions exist of the term “confidence” which are sometimes used interchangeably. This is a position paper, in which we aim to give an overview on existing definitions,
thereby clarifying the meaning of the used terms to facilitate further research in this field. Based on these clarifications, we develop a theory to compare confidence measures with respect to their quality.
Keywords: Optical flow, confidence measure, performance evaluation
|
|
|
Debora Gil, Agnes Borras, Ruth Aris, Mariano Vazquez, Pierre Lafortune, & Guillame Houzeaux. (2012). "What a difference in biomechanics cardiac fiber makes " In Statistical Atlases And Computational Models Of The Heart: Imaging and Modelling Challenges (Vol. 7746, pp. 253–260). Springer Berlin Heidelberg.
Abstract: Computational simulations of the heart are a powerful tool for a comprehensive understanding of cardiac function and its intrinsic relationship with its muscular architecture. Cardiac biomechanical models require a vector field representing the orientation of cardiac fibers. A wrong orientation of the fibers can lead to a
non-realistic simulation of the heart functionality. In this paper we explore the impact of the fiber information on the simulated biomechanics of cardiac muscular anatomy. We have used the John Hopkins database to perform a biomechanical simulation using both a synthetic benchmark fiber distribution and the data obtained experimentally from DTI. Results illustrate how differences in fiber orientation affect heart deformation along cardiac cycle.
|
|
|
Sergio Vera, Miguel Angel Gonzalez Ballester, & Debora Gil. (2013). "Volumetric Anatomical Parameterization and Meshing for Inter-patient Liver Coordinate System Deffinition " In 16th International Conference on Medical Image Computing and Computer Assisted Intervention.
|
|
|
Guillermo Torres, Debora Gil, Antoni Rosell, S. Mena, & Carles Sanchez. (2023)." Virtual Radiomics Biopsy for the Histological Diagnosis of Pulmonary Nodules – Intermediate Results of the RadioLung Project" . International Journal of Computer Assisted Radiology and Surgery, .
|
|
|
Guillermo Torres, Debora Gil, Antoni Rosell, S. Mena, & Carles Sanchez. (2023)." Virtual Radiomics Biopsy for the Histological Diagnosis of Pulmonary Nodules" In 37th International Congress and Exhibition is organized by Computer Assisted Radiology and Surgery.
|
|
|
Aura Hernandez-Sabate, Petia Radeva, Antonio Tovar, & Debora Gil. (2006). "Vessel structures alignment by spectral analysis of ivus sequences " In Proc. of CVII, MICCAI Workshop (pp. 39–36). 1st International Wokshop on Computer Vision for Intravascular and Intracardiac Imaging (CVII’06). Copenhaguen (Denmark),.
Abstract: Three-dimensional intravascular ultrasound (IVUS) allows to visualize and obtain volumetric measurements of coronary lesions through an exploration of the cross sections and longitudinal views of arteries. However, the visualization and subsequent morpho-geometric measurements in IVUS longitudinal cuts are subject to distortion caused by periodic image/vessel motion around the IVUS catheter. Usually, to overcome the image motion artifact ECG-gating and image-gated approaches are proposed, leading to slowing the pullback acquisition or disregarding part of IVUS data. In this paper, we argue that the image motion is due to 3-D vessel geometry as well as cardiac dynamics, and propose a dynamic model based on the tracking of an elliptical vessel approximation to recover the rigid transformation and align IVUS images without loosing any IVUS data. We report an extensive validation with synthetic simulated data and in vivo IVUS sequences of 30 patients achieving an average reduction of the image artifact of 97% in synthetic data and 79% in real-data. Our study shows that IVUS alignment improves longitudinal analysis of the IVUS data and is a necessary step towards accurate reconstruction and volumetric measurements of 3-D IVUS.
|
|
|
Jaume Garcia, Debora Gil, Sandra Pujades, & Francesc Carreras. (2008). "Valoracion de la Funcion del Ventriculo Izquierdo mediante Modelos Regionales Hiperparametricos " . Revista Española de Cardiologia, 61(3), 79.
Abstract: La mayoría de la enfermedades cardiovasculares afectan a las propiedades contráctiles de la banda ventricular helicoidal. Esto se refleja en una variación del comportamiento normal de la función ventricular. Parámetros locales tales como los strains, o la deformación experimentada por el tejido, son indicadores capaces de detectar anomalías funcionales en territorios específicos. A menudo, dichos parámetros son considerados de forma separada. En este trabajo presentamos un marco computacional (el Dominio Paramétrico Normalizado, DPN) que permite integrarlos en hiperparámetros funcionales y estudiar sus rangos de normalidad. Dichos rangos permiten valorar de forma objetiva la función regional de cualquier nuevo paciente. Para ello, consideramos secuencias de resonancia magnética etiquetada a nivel basal, medio y apical. Los hiperparámetros se obtienen a partir del movimiento intramural del VI estimado mediante el método Harmonic Phase Flow. El DPN se define a partir de en una parametrización del Ventrículo Izquierdo (VI) en sus coordenadas radiales y circunferencial basada en criterios anatómicos. El paso de los hiperparámetros al DPN hace posible la comparación entre distintos pacientes. Los rangos de normalidad se definen mediante análisis estadístico de valores de voluntarios sanos en 45 regiones del DPN a lo largo de 9 fases sistólicas. Se ha usado un conjunto de 19 (14 H; E: 30.7±7.5) voluntarios sanos para crear los patrones de normalidad y se han validado usando 2 controles sanos y 3 pacientes afectados de contractilidad global reducida. Para los controles los resultados regionales se han ajustado dentro de la normalidad, mientras que para los pacientes se han obtenido valores anormales en las zonas descritas, localizando y cuantificando así el diagnóstico empírico.
|
|
|
Ferran Poveda, Jaume Garcia, Enric Marti, & Debora Gil. (2010). "Validation of the myocardial architecture in DT-MRI tractography " In Medical Image Computing in Catalunya: Graduate Student Workshop (pp. 29–30). Girona (Spain).
Abstract: Deep understanding of myocardial structure may help to link form and funcion of the heart unraveling crucial knowledge for medical and surgical clinical procedures and studies. In this work we introduce two visualization techniques based on DT-MRI streamlining able to decipher interesting properties of the architectural organization of the heart.
|
|
|
Oriol Rodriguez-Leon, Josefina Mauri, Eduard Fernandez-Nofrerias, Antonio Tovar, Vicente del Valle, Aura Hernandez-Sabate, et al. (2004)." Utilizacion de la estructura de los campos vectoriales para la deteccion de la Adventicia en imagenes de Ecografia Intracoronaria" . Revista Española de Cardiología, 57(2), 100.
|
|