Mariano Vazquez, Ruth Aris, Guillaume Hozeaux, R.Aubry, P.Villar, Jaume Garcia, et al. (2011). "A massively parallel computational electrophysiology model of the heart " . International Journal for Numerical Methods in Biomedical Engineering, 27, 1911–1929.
Abstract: This paper presents a patient-sensitive simulation strategy capable of using the most efficient way the high-performance computational resources. The proposed strategy directly involves three different players: Computational Mechanics Scientists (CMS), Image Processing Scientists and Cardiologists, each one mastering its own expertise area within the project. This paper describes the general integrative scheme but focusing on the CMS side presents a massively parallel implementation of computational electrophysiology applied to cardiac tissue simulation. The paper covers different angles of the computational problem: equations, numerical issues, the algorithm and parallel implementation. The proposed methodology is illustrated with numerical simulations testing all the different possibilities, ranging from small domains up to very large ones. A key issue is the almost ideal scalability not only for large and complex problems but also for medium-size meshes. The explicit formulation is particularly well suited for solving this highly transient problems, with very short time-scale.
Keywords: computational electrophysiology; parallelization; finite element methods
|
|
|
Albert Andaluz, Francesc Carreras, Debora Gil, & Jaume Garcia. (2010). "Una aplicació amigable pel càlcul de indicadors clínics del ventricle esquerre ". Barcelona: Biocat.
|
|
|
Cristina Cañero, Petia Radeva, Oriol Pujol, Ricardo Toledo, Debora Gil, J. Saludes, et al. (1999). "Optimal Stent Implantation: Three-dimensional Evaluation of the Mutual Position of Stent and Vessel via Intracoronary Ecography " In Proceedings of International Conference on Computer in Cardiology (CIC´99).
Abstract: We present a new automatic technique to visualize and quantify the mutual position between the stent and the vessel wall by considering their three-dimensional reconstruction. Two deformable generalized cylinders adapt to the image features in all IVUS planes corresponding to the vessel wall and the stent in order to reconstruct the boundaries of the stent and the vessel in space. The image features that characterize the stent and the vessel wall are determined in terms of edge and ridge image detectors taking into account the gray level of the image pixels. We show that the 30 reconstruction by deformable cylinders is accurate and robust due to the spatial data coherence in the considered volumetric IVUS image. The main clinic utility of the stent and vessel reconstruction by deformable’ cylinders consists of its possibility to visualize and to assess the optimal stent introduction.
|
|
|
Cristina Cañero, Petia Radeva, Oriol Pujol, Ricardo Toledo, Debora Gil, J. Saludes, et al. (1999). "Three-dimensional reconstruction and quantification of the coronary tree using intravascular ultrasound images " In Proceedings of International Conference on Computer in Cardiology (CIC´99).
Abstract: In this paper we propose a new Computer Vision technique to reconstruct the vascular wall in space using a deformable model-based technique and compounding methods, based in biplane angiography and intravascular ultrasound data jicsion. It is also proposed a generalpurpose three-dimensional guided interpolation method. The three dimensional centerline of the vessel is reconstructed from geometrically corrected biplane angiographies using automatic segmentation methods and snakes. The IVUS image planes are located in the threedimensional space and correctly oriented. A led interpolation method based in B-SurJaces and snakes isused to fill the gaps among image planes
|
|
|
Debora Gil, Jordi Gonzalez, & Gemma Sanchez (Eds.). (2007)." Computer Vision: Advances in Research and Development" . 2. Bellaterra (Spain): UAB.
|
|
|
Francesc Carreras, Jaume Garcia, Debora Gil, Sandra Pujadas, Chi ho Lion, R.Suarez-Arias, et al. (2012). "Left ventricular torsion and longitudinal shortening: two fundamental components of myocardial mechanics assessed by tagged cine-MRI in normal subjects " . International Journal of Cardiovascular Imaging, 28(2), 273–284.
Abstract: Cardiac magnetic resonance imaging (Cardiac MRI) has become a gold standard diagnostic technique for the assessment of cardiac mechanics, allowing the non-invasive calculation of left ventric- ular long axis longitudinal shortening (LVLS) and absolute myocardial torsion (AMT) between basal and apical left ventricular slices, a movement directly related to the helicoidal anatomic disposition of the myocardial fibers. The aim of this study is to determine AMT and LVLS behaviour and normal values from a group of healthy subjects. A group of 21 healthy volunteers (15 males) (age: 23–55 y.o., mean:30.7 ± 7.5) were prospectively included in an obser- vational study by Cardiac MRI. Left ventricular rotation (degrees) was calculated by custom-made software (Harmonic Phase Flow) in consecutive LV short axis planes tagged cine-MRI sequences. AMT was determined from the difference between basal and apical planes LV rotations. LVLS (%) was determined from the LV longitudinal and horizontal axis cine-MRI images. All the 21 cases studied were interpretable, although in three cases the value of the LV apical rotation could not be determined. The mean rotation of the basal and apical planes at end-systole were -3.71° ± 0.84° and 6.73° ± 1.69° (n:18) respectively, resulting in a LV mean AMT of 10.48° ± 1.63° (n:18). End-systolic mean LVLS was 19.07 ± 2.71%. Cardiac MRI allows for the calculation of AMT and LVLS, fundamental functional components of the ventricular twist mechanics conditioned, in turn, by the anatomical helical layout of the myocardial fibers. These values provide complementary information about systolic ventricular function in relation to the traditional parameters used in daily practice.
Keywords: Magnetic resonance imaging (MRI); Tagging MRI; Cardiac mechanics; Ventricular torsion
|
|
|
Jaume Garcia, Debora Gil, Francesc Carreras, Sandra Pujades, & R.Leta. (2007). "Modelització 4-Dimensional de la Funció Siatólica del Ventricle Esquerre " In XIX Congrés de la Societat Catalana de Cardiologia de Barcelona (pp. 133–134). Barcelona (Spain).
Abstract: L’evolució tecnològica en el tractament de les imatges mèdiques permet reconstruir, amb el software apropiat, imatges tridimensionals de les estructures cardiovasculars i dotar-les de moviment. Les imatges 4D resultants faciliten l’estudi de la fisiopatologia de la insuficiència cardíaca en base als transtorns de l’activació electromecànica ventricular, el que pot ser d’interès en el procés de selecció de pacients candidats a teràpies de resincronització. Presentem els resultats preliminars de la reconstrucció 4D del ventricle esquerre (VE) a partir de les seqüències de tagging miocàrdic del VE.
|
|
|
Jaume Garcia, Debora Gil, Luis Badiella, Aura Hernandez-Sabate, Francesc Carreras, Sandra Pujades, et al. (2010). "A Normalized Framework for the Design of Feature Spaces Assessing the Left Ventricular Function " . IEEE Transactions on Medical Imaging, 29(3), 733–745.
Abstract: A through description of the left ventricle functionality requires combining complementary regional scores. A main limitation is the lack of multiparametric normality models oriented to the assessment of regional wall motion abnormalities (RWMA). This paper covers two main topics involved in RWMA assessment. We propose a general framework allowing the fusion and comparison across subjects of different regional scores. Our framework is used to explore which combination of regional scores (including 2-D motion and strains) is better suited for RWMA detection. Our statistical analysis indicates that for a proper (within interobserver variability) identification of RWMA, models should consider motion and extreme strains.
|
|
|
Jaume Garcia, Debora Gil, A.Bajo, M.J.Ledesma-Carbayo, & C.SantaMarta. (2008). "Influence of the temporal resolution on the quantification of displacement fields in cardiac magnetic resonance tagged images " In Alan Murray (Ed.), Proc. Computers in Cardiology (Vol. 35, pp. 785–788).
Abstract: It is difficult to acquire tagged cardiac MR images with a high temporal and spatial resolution using clinical MR scanners. However, if such images are used for quantifying scores based on motion, it is essential a resolution as high as possible. This paper explores the influence of the temporal resolution of a tagged series on the quantification of myocardial dynamic parameters. To such purpose we have designed a SPAMM (Spatial Modulation of Magnetization) sequence allowing acquisition of sequences at simple and double temporal resolution. Sequences are processed to compute myocardial motion by an automatic technique based on the tracking of the harmonic phase of tagged images (the Harmonic Phase Flow, HPF). The results have been compared to manual tracking of myocardial tags. The error in displacement fields for double resolution sequences reduces 17%.
|
|
|
Jaume Garcia, Debora Gil, Joel Barajas, Francesc Carreras, Sandra Pujades, & Petia Radeva. (2006). "Characterization of ventricular torsion in healthy subjects using Gabor filters and a variational framework " In Proc. Computers in Cardiology (pp. 877–880).
Abstract: In this work, we present a fully automated method for tissue deformation estimation in tagged magnetic resonance images (TMRI). Gabor filter banks, tuned independently for each left ventricle level, provide optimally filtered complex images which phase remains constant along the cardiac cycle. This fact can be thought as the brightness constancy condition required by classical optical flow (OF) methods. Pairs of these filtered sequences, together with a variational formulation are used in a second step to obtain dense continuous deformation maps that we call Harmonic Phase Flow. This method has been used to determine reference values of ventricular torsion (VT) in a set of 8 healthy volunteers. The results encourage the use of VT as a useful parameter for ventricular function assessment in clinical routine.
|
|