|
Records |
Links |
|
Author |
Aura Hernandez-Sabate |
|
|
Title |
Automatic adventitia segmentation in IntraVascular UltraSound images |
Type |
Report |
|
Year |
2005 |
Publication |
CVC Technical Report |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
85 |
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
A usual tool in cardiac disease diagnosis is vessel plaque assessment by analysis of IVUS sequences. Manual detection of lumen-intima, intima-media and media-adventitia vessel borders is the main activity of physicians in the process of plaque quantification. Large variety in vessel border descriptors, as well as, shades, artifacts and blurred response due to ultrasound physical properties troubles automated media-adventitia segmentation. This experimental work presents a solution to such a complex problem. The process blends advanced anisotropic filtering operators and statistic classification techniques, achieving an efficient vessel border modelling strategy. First of all, we introduce the theoretic base of the method. After that, we show the steps of the algorithm, validating the method with statistics that show that the media-adventitia border detection achieves an accuracy in the range of inter-observer variability regardless of plaque nature, vessel geometry and incomplete vessel borders. Finally, we present a little Matlab application to the automatic media-adventitia border. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
Master's thesis |
|
|
Publisher |
|
Place of Publication |
08193 Bellaterra, Barcelona (Spain) |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ Her2005 |
Serial |
1544 |
|
Permanent link to this record |
|
|
|
|
Author |
Aura Hernandez-Sabate; Debora Gil; Petia Radeva |
|
|
Title |
A Deterministic-Statistical Strategy for Adventitia Segmentation in IVUS images |
Type |
Report |
|
Year |
2005 |
Publication |
CVC Technical Report |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
89 |
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
A useful tool for some specific studies in cardiac disease diagnosis is vessel plaque assessment by analysis of IVUS sequences. Manual detection of luminal (inner) and media-adventitia (external) vessel borders is the main activity of physicians in the process of lumen narrowing (plaque) quantification. Difficult definition of vessel border descriptors, as well as, shades, artifacts and blurred signal response due to ultrasound physical properties troubles automated adventitia segmentation. In order to efficiently approach such a complex problem, we propose blending advanced anisotropic filtering operators and statistical classification techniques into a vessel border modelling strategy. Our systematic statistical analysis shows that the reported adventitia detection achieves an accuracy in the range of inter-observer variability regardless of plaque nature, vessel geometry and incomplete vessel borders. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ HGR2005a |
Serial |
1548 |
|
Permanent link to this record |
|
|
|
|
Author |
Patricia Marquez |
|
|
Title |
Conditions Ensuring Accuracy of Local Optical Flow Schemes |
Type |
Report |
|
Year |
2010 |
Publication |
CVC Tehcnical Report |
Abbreviated Journal |
|
|
|
Volume |
157 |
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
Accurate computation of optical flow is a key-point in many image processing fields. Detection of anomalous and unpredicted agents (such as pedestrians, bikers or cars) in urban scenes or pathology discrimination in medical imaging sequences, to mention just a two. The above kinds sequences present two main difficulties for standard optical flow techniques. On one hand, variability in acquisition conditions (illuminance, medical imaging modality, ...) force an alterantive representation for images fulfilling the britghtness constancy constrain. On the hand, current variational schemes produce oversmoothed fields unable to properly model discontinuous behaviours such as collisions or functionless pathological areas. This master project explores the abilities and limitations of local and global optical flow approaches. The master student will put especial emphasis in the theoretical grounds behind in order to design a variational framework combining the theoretical advantages of the considered techniques. In particular an optical flow based on Gabor phase tracking (developed in the group for medical imaging) will be generalized to urban scenes. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
Master's thesis |
|
|
Publisher |
|
Place of Publication |
Bellaterra 08193, Barcelona, Spain |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ Mar2010 |
Serial |
1582 |
|
Permanent link to this record |
|
|
|
|
Author |
Ferran Poveda |
|
|
Title |
Visualització i interpretació tridimensional de l’arquitectura de les fibres musculars del miocardi |
Type |
Report |
|
Year |
2009 |
Publication |
Master en Tecnologies Multimedia |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
Master's thesis |
|
|
Publisher |
|
Place of Publication |
08193 Bellaterra, Barcelona (Spain) |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ Pov2009 |
Serial |
1625 |
|
Permanent link to this record |
|
|
|
|
Author |
Sergio Vera |
|
|
Title |
Finger joint modelling from hand X-ray images for assessing rheumatoid arthritis |
Type |
Report |
|
Year |
2010 |
Publication |
CVC Technical Report |
Abbreviated Journal |
|
|
|
Volume |
164 |
Issue |
|
Pages |
|
|
|
Keywords |
Rheumatoid arthritis; joint detection; X-ray; Van der Heijde score |
|
|
Abstract |
Rheumatoid arthritis is an autoimmune, systemic, inflammatory disorder that mainly af- fects bone joints. While there is no cure for this disease, continuous advances on palliative treatments require frequent verification of patient’s illness evolution. Such evolution is mea- sured through several available semi-quantitative methods that require evaluation of hand and foot X-ray images. Accurate assessment is a time consuming task that requires highly trained personnel. This hinders a generalized use in clinical practice for early diagnose and disease follow-up. In the context of the automatization of such evaluation methods we present a method for detection and characterization of finger joints in hand radiography images. Several measures for assessing the reduction of joint space width are proposed. We compare for the first time such measures to the Van der Heijde score, the gold standard method for rheumatoid arthritis assessment. The proposed method outperforms existing strategies with a detection rate above 95%. Our comparison to Van der Heijde index shows a promising correlation that encourages further research. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
Master's thesis |
|
|
Publisher |
|
Place of Publication |
Bellaterra 01893, Barcelona, Spain |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ Ver2010 |
Serial |
1661 |
|
Permanent link to this record |
|
|
|
|
Author |
Joan M. Nuñez |
|
|
Title |
Computer vision techniques for characterization of finger joints in X-ray image |
Type |
Report |
|
Year |
2011 |
Publication |
CVC Technical Report |
Abbreviated Journal |
|
|
|
Volume |
165 |
Issue |
|
Pages |
|
|
|
Keywords |
Rheumatoid arthritis, X-ray, Sharp Van der Heijde, joint characterization, sclerosis detection, bone detection, edge, ridge |
|
|
Abstract |
Rheumatoid arthritis (RA) is an autoimmune inflammatory type of arthritis which mainly affects hands on its first stages. Though it is a chronic disease and there is no cure for it, treatments require an accurate assessment of illness evolution. Such assessment is based on evaluation of hand X-ray images by using one of the several available semi-quantitative methods. This task requires highly trained medical personnel. That is why the automation of the assessment would allow professionals to save time and effort. Two stages are involved in this task. Firstly, the joint detection, afterwards, the joint characterization. Unlike the little existing previous work, this contribution clearly separates those two stages and sets the foundations of a modular assessment system focusing on the characterization stage. A hand joint dataset is created and an accurate data analysis is achieved in order to identify relevant features. Since the sclerosis and the lower bone were decided to be the most important features, different computer vision techniques were used in order to develop a detector system for both of them. Joint space width measures are provided and their correlation with Sharp-Van der Heijde is verified |
|
|
Address |
Bellaterra (Barcelona) |
|
|
Corporate Author |
Computer Vision Center |
Thesis |
Master's thesis |
|
|
Publisher |
|
Place of Publication |
|
Editor |
Dr. Fernando Vilariño and Dra. Debora Gil |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MV;IAM; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ Nuñ2011 |
Serial |
1795 |
|
Permanent link to this record |
|
|
|
|
Author |
Carles Sanchez |
|
|
Title |
Tracheal ring detection in bronchoscopy |
Type |
Report |
|
Year |
2011 |
Publication |
CVC Technical Report |
Abbreviated Journal |
|
|
|
Volume |
168 |
Issue |
|
Pages |
|
|
|
Keywords |
Bronchoscopy, tracheal ring, segmentation |
|
|
Abstract |
Endoscopy is the process in which a camera is introduced inside a human.
Given that endoscopy provides realistic images (in contrast to other modalities) and allows non-invase minimal intervention procedures (which can aid in diagnosis and surgical interventions), its use has spreaded during last decades.
In this project we will focus on bronchoscopic procedures, during which the camera is introduced through the trachea in order to have a diagnostic of the patient. The diagnostic interventions are focused on: degree of stenosis (reduction in tracheal area), prosthesis or early diagnosis of tumors. In the first case, assessment of the luminal area and the calculation of the diameters of the tracheal rings are required. A main limitation is that all the process is done by hand,
which means that the doctor takes all the measurements and decisions just by looking at the screen. As far as we know there is no computational framework for helping the doctors in the diagnosis.
This project will consist of analysing bronchoscopic videos in order to extract useful information for the diagnostic of the degree of stenosis. In particular we will focus on segmentation of the tracheal rings. As a result of this project several strategies (for detecting tracheal rings) had been implemented in order to compare their performance. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
Master's thesis |
|
|
Publisher |
|
Place of Publication |
|
Editor |
Debora Gil, F.Javier Sanchez |
|
|
Language |
english |
Summary Language |
english |
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MV |
Approved |
no |
|
|
Call Number |
IAM @ iam @ San2011 |
Serial |
1841 |
|
Permanent link to this record |
|
|
|
|
Author |
Francesco Brughi |
|
|
Title |
Artistic Heritage Motive Retrieval: an Explorative Study |
Type |
Report |
|
Year |
2013 |
Publication |
CVC Technical Report |
Abbreviated Journal |
|
|
|
Volume |
176 |
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
Master's thesis |
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
Admin @ si @ Bru2013 |
Serial |
2410 |
|
Permanent link to this record |
|
|
|
|
Author |
Antonio Esteban Lansaque |
|
|
Title |
3D reconstruction and recognition using structured ligth |
Type |
Report |
|
Year |
2014 |
Publication |
CVC Technical Report |
Abbreviated Journal |
|
|
|
Volume |
179 |
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
This work covers the problem of 3D reconstruction, recognition and 6DOF pose estimation. The goal of this project is to reconstruct a 3D scene and to align an object model of the industrial pieces onto the reconstructed scene. The reconstruction algorithm is based on stereo techniques and the recognition algorithm is based on SHOT descriptors computed on a set of uniform keypoints. Correspondences are used to estimate a first 6DOF transformation that maps the model onto the scene and then ICP algorithm is used to refine the transformation. In order to check the effectiveness of the proposed algorithm, several experiments were performed. These experiments were conducted on a lab environment in order to get results under the same conditions in all of them. Although obtained results are not real time results, the proposed algorithm ends up with high rates of object recognition. |
|
|
Address |
UAB; September 2014 |
|
|
Corporate Author |
|
Thesis |
Master's thesis |
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; 600.075 |
Approved |
no |
|
|
Call Number |
Admin @ si @ Est2014 |
Serial |
2578 |
|
Permanent link to this record |