Sergio Vera. (2010). "Finger joint modelling from hand X-ray images for assessing rheumatoid arthritis " (Vol. 164). Master's thesis, , Bellaterra 01893, Barcelona, Spain.
Abstract: Rheumatoid arthritis is an autoimmune, systemic, inflammatory disorder that mainly af- fects bone joints. While there is no cure for this disease, continuous advances on palliative treatments require frequent verification of patient’s illness evolution. Such evolution is mea- sured through several available semi-quantitative methods that require evaluation of hand and foot X-ray images. Accurate assessment is a time consuming task that requires highly trained personnel. This hinders a generalized use in clinical practice for early diagnose and disease follow-up. In the context of the automatization of such evaluation methods we present a method for detection and characterization of finger joints in hand radiography images. Several measures for assessing the reduction of joint space width are proposed. We compare for the first time such measures to the Van der Heijde score, the gold standard method for rheumatoid arthritis assessment. The proposed method outperforms existing strategies with a detection rate above 95%. Our comparison to Van der Heijde index shows a promising correlation that encourages further research.
Keywords: Rheumatoid arthritis; joint detection; X-ray; Van der Heijde score
|
|
|
Sergio Vera, Miguel Angel Gonzalez Ballester, & Debora Gil. (2012). "Optimal Medial Surface Generation for Anatomical Volume Representations " In MichaelW. David and Vannier H. and H. Yoshida (Ed.), Abdominal Imaging. Computational and Clinical Applications (Vol. 7601, pp. 265–273). Lecture Notes in Computer Science. Springer Berlin Heidelberg.
Abstract: Medial representations are a widely used technique in abdominal organ shape representation and parametrization. Those methods require good medial manifolds as a starting point. Any medial
surface used to parametrize a volume should be simple enough to allow an easy manipulation and complete enough to allow an accurate reconstruction of the volume. Obtaining good quality medial
surfaces is still a problem with current iterative thinning methods. This forces the usage of generic, pre-calculated medial templates that are adapted to the final shape at the cost of a drop in volume reconstruction.
This paper describes an operator for generation of medial structures that generates clean and complete manifolds well suited for their further use in medial representations of abdominal organ volumes. While being simpler than thinning surfaces, experiments show its high performance in volume reconstruction and preservation of medial surface main branching topology.
Keywords: Medial surface representation; volume reconstruction
|
|
|
Debora Gil, Agnes Borras, Sergio Vera, & Miguel Angel Gonzalez Ballester. (2013). "A Validation Benchmark for Assessment of Medial Surface Quality for Medical Applications " In 9th International Conference on Computer Vision Systems (Vol. 7963, pp. 334–343). Springer Berlin Heidelberg.
Abstract: Confident use of medial surfaces in medical decision support systems requires evaluating their quality for detecting pathological deformations and describing anatomical volumes. Validation in the medical imaging field is a challenging task mainly due to the difficulties for getting consensual ground truth. In this paper we propose a validation benchmark for assessing medial surfaces in the context of medical applications. Our benchmark includes a home-made database of synthetic medial surfaces and volumes and specific scores for evaluating surface accuracy, its stability against volume deformations and its capabilities for accurate reconstruction of anatomical volumes.
Keywords: Medial Surfaces; Shape Representation; Medical Applications; Performance Evaluation
|
|
|
Sergio Vera, Miguel Angel Gonzalez Ballester, & Debora Gil. (2015). "A Novel Cochlear Reference Frame Based On The Laplace Equation " In 29th international Congress and Exhibition on Computer Assisted Radiology and Surgery (Vol. 10, pp. 1–312).
|
|
|
Sergio Vera, Miguel Angel Gonzalez Ballester, & Debora Gil. (2013). "Volumetric Anatomical Parameterization and Meshing for Inter-patient Liver Coordinate System Deffinition " In 16th International Conference on Medical Image Computing and Computer Assisted Intervention.
|
|