|
Carles Sanchez. (2011). "Tracheal ring detection in bronchoscopy " (F. J. S. Debora Gil, Ed.) (Vol. 168). Master's thesis, , .
Abstract: Endoscopy is the process in which a camera is introduced inside a human.
Given that endoscopy provides realistic images (in contrast to other modalities) and allows non-invase minimal intervention procedures (which can aid in diagnosis and surgical interventions), its use has spreaded during last decades.
In this project we will focus on bronchoscopic procedures, during which the camera is introduced through the trachea in order to have a diagnostic of the patient. The diagnostic interventions are focused on: degree of stenosis (reduction in tracheal area), prosthesis or early diagnosis of tumors. In the first case, assessment of the luminal area and the calculation of the diameters of the tracheal rings are required. A main limitation is that all the process is done by hand,
which means that the doctor takes all the measurements and decisions just by looking at the screen. As far as we know there is no computational framework for helping the doctors in the diagnosis.
This project will consist of analysing bronchoscopic videos in order to extract useful information for the diagnostic of the degree of stenosis. In particular we will focus on segmentation of the tracheal rings. As a result of this project several strategies (for detecting tracheal rings) had been implemented in order to compare their performance.
Keywords: Bronchoscopy, tracheal ring, segmentation
|
|
|
Francesco Brughi. (2013)." Artistic Heritage Motive Retrieval: an Explorative Study" (Vol. 176). Master's thesis, , .
|
|
|
Antonio Esteban Lansaque. (2014)." 3D reconstruction and recognition using structured ligth" (Vol. 179). Master's thesis, , .
Abstract: This work covers the problem of 3D reconstruction, recognition and 6DOF pose estimation. The goal of this project is to reconstruct a 3D scene and to align an object model of the industrial pieces onto the reconstructed scene. The reconstruction algorithm is based on stereo techniques and the recognition algorithm is based on SHOT descriptors computed on a set of uniform keypoints. Correspondences are used to estimate a first 6DOF transformation that maps the model onto the scene and then ICP algorithm is used to refine the transformation. In order to check the effectiveness of the proposed algorithm, several experiments were performed. These experiments were conducted on a lab environment in order to get results under the same conditions in all of them. Although obtained results are not real time results, the proposed algorithm ends up with high rates of object recognition.
|
|
|
Albert Andaluz. (2012). "Harmonic Phase Flow: User's guide ". Barcelona: CVC.
Abstract: HPF is a plugin for the computation of clinical scores under Osirix.
This manual provides a basic guide for experienced clinical staff. Chapter 1 provides the theoretical background in which this plugin is based.
Next, in chapter 2 we provide basic instructions for installing and uninstalling this plugin. chapter 3we shows a step-by-step scenario to compute clinical scores from tagged-MRI images with HPF. Finally, in chapter 4 we provide a quick guide for plugin developers
|
|
|
J. Mauri, Eduard Fernandez-Nofrerias, B. Garcia del Blanco, E. Iraculis, J.A. Gomez-Hospital, J. Comin, et al. (2000)." Moviment del vas en l anàlisi d imatges d ecografia intracoronària: un model matemàtic" In Congrés de la Societat Catalana de Cardiologia..
|
|
|
J. Mauri, Eduard Fernandez-Nofrerias, J. Comin, B. Garcia del Blanco, E. Iraculis, J.A. Gomez-Hospital, et al. (2000)." Avaluació del Conjunt Stent/Artèria mitjançant ecografia intracoronària: lentorn informàtic" In Congrés de la Societat Catalana de Cardiologia..
|
|
|
Aura Hernandez-Sabate, Monica Mitiko, Sergio Shiguemi, & Debora Gil. (2010). "A validation protocol for assessing cardiac phase retrieval in IntraVascular UltraSound " In Computing in Cardiology (Vol. 37, pp. 899–902). IEEE.
Abstract: A good reliable approach to cardiac triggering is of utmost importance in obtaining accurate quantitative results of atherosclerotic plaque burden from the analysis of IntraVascular UltraSound. Although, in the last years, there has been an increase in research of methods for retrospective gating, there is no general consensus in a validation protocol. Many methods are based on quality assessment of longitudinal cuts appearance and those reporting quantitative numbers do not follow a standard protocol. Such heterogeneity in validation protocols makes faithful comparison across methods a difficult task. We propose a validation protocol based on the variability of the retrieved cardiac phase and explore the capability of several quality measures for quantifying such variability. An ideal detector, suitable for its application in clinical practice, should produce stable phases. That is, it should always sample the same cardiac cycle fraction. In this context, one should measure the variability (variance) of a candidate sampling with respect a ground truth (reference) sampling, since the variance would indicate how spread we are aiming a target. In order to quantify the deviation between the sampling and the ground truth, we have considered two quality scores reported in the literature: signed distance to the closest reference sample and distance to the right of each reference sample. We have also considered the residuals of the regression line of reference against candidate sampling. The performance of the measures has been explored on a set of synthetic samplings covering different cardiac cycle fractions and variabilities. From our simulations, we conclude that the metrics related to distances are sensitive to the shift considered while the residuals are robust against fraction and variabilities as far as one can establish a pair-wise correspondence between candidate and reference. We will further investigate the impact of false positive and negative detections in experimental data.
|
|
|
Jaume Garcia, Joel Barajas, Francesc Carreras, Sandra Pujades, & Petia Radeva. (2005). "An intuitive validation technique to compare local versus global tagged MRI analysis " In Computers In Cardiology (Vol. 32, 29–32).
Abstract: Myocardium appears as a uniform tissue that seen in convectional Magnetic Resonance Images (MRI) shows just the contractile part of its movement. MR Tagging is a unique imaging technique that prints a grid over the tissue which moves according to the underlying movement of the myocardium revealing the true deformation of the cardiac muscle. Optical flow techniques based on spectral information estimate tissue displacement by analyzing information encoded in the phase maps which can be obtained using, local (Gabor) and global (HARP) methods. In this paper we compare both in synthetic and real Tagged MR sequences. We conclude that local method is slightly more accurate than the global one. On the other hand, global method is more efficient as it is much faster and less parameters have to be taken into account
|
|
|
David Rotger, Misael Rosales, Jaume Garcia, Oriol Pujol, J. Mauri, & Petia Radeva. (2003). "Active Vessel: A New Multimedia Workstation for Intravascular Ultrasound and Angiography Fusion " . Computers in Cardiology, 30, 65–68.
Abstract: AcriveVessel is a new multimedia workstation which enables the visualization, acquisition and handling of both image modalities, on- and ofline. It enables DICOM v3.0 decompression and browsing, video acquisition,repmduction and storage for IntraVascular UltraSound (IVUS) and angiograms with their corresponding ECG,automatic catheter segmentation in angiography images (using fast marching algorithm). BSpline models definition for vessel layers on IVUS images sequence and an extensively validated tool to fuse information. This approach defines the correspondence of every IVUS image with its correspondent point in the angiogram and viceversa. The 3 0 reconstruction of the NUS catheterhessel enables real distance measurements as well as threedimensional visualization showing vessel tortuosity in the space.
|
|
|
Jorge Bernal, F. Javier Sanchez, Gloria Fernandez Esparrach, Debora Gil, Cristina Rodriguez de Miguel, & Fernando Vilariño. (2015). "WM-DOVA Maps for Accurate Polyp Highlighting in Colonoscopy: Validation vs. Saliency Maps from Physicians " . Computerized Medical Imaging and Graphics, 43, 99–111.
Abstract: We introduce in this paper a novel polyp localization method for colonoscopy videos. Our method is based on a model of appearance for polyps which defines polyp boundaries in terms of valley information. We propose the integration of valley information in a robust way fostering complete, concave and continuous boundaries typically associated to polyps. This integration is done by using a window of radial sectors which accumulate valley information to create WMDOVA1 energy maps related with the likelihood of polyp presence. We perform a double validation of our maps, which include the introduction of two new databases, including the first, up to our knowledge, fully annotated database with clinical metadata associated. First we assess that the highest value corresponds with the location of the polyp in the image. Second, we show that WM-DOVA energy maps can be comparable with saliency maps obtained from physicians' fixations obtained via an eye-tracker. Finally, we prove that our method outperforms state-of-the-art computational saliency results. Our method shows good performance, particularly for small polyps which are reported to be the main sources of polyp miss-rate, which indicates the potential applicability of our method in clinical practice.
Keywords: Polyp localization; Energy Maps; Colonoscopy; Saliency; Valley detection
|
|