toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
  Records Links
Author Oriol Rodriguez-Leon; Josefina Mauri;Eduard Fernandez-Nofrerias; C.Garcia; R.Villuendas; Vicente del Valle; Debora Gil;Petia Radeva edit  openurl
  Title Reconstruction of a spatio-temporal model of the intima layer from intravascular ultrasound sequences Type Journal Article
  Year 2003 Publication European Heart Journal Abbreviated Journal  
  Volume Issue Pages  
  Keywords  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference ESC Congress  
  Notes (up) IAM;MILAB Approved no  
  Call Number IAM @ iam @ RMF2003c Serial 1641  
Permanent link to this record
 

 
Author Oriol Rodriguez-Leon; Josefina Mauri;Eduard Fernandez-Nofrerias; Antonio Tovar; Vicente del Valle; Aura Hernandez-Sabate; Debora Gil; Petia Radeva edit  openurl
  Title Utilización de la Estructura de los Campos Vectoriales para la Detección de la Adventicia en Imágenes de Ecografía Intracoronaria Type Journal Article
  Year 2004 Publication Revista Internacional de Enfermedades Cardiovasculares Revista Española de Cardiología Abbreviated Journal  
  Volume 57 Issue 2 Pages 100  
  Keywords  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference SEC  
  Notes (up) IAM;MILAB Approved no  
  Call Number IAM @ iam @ RMF2004 Serial 1642  
Permanent link to this record
 

 
Author Oriol Rodriguez-Leon; Eduard Fernandez-Nofrerias; Josefina Mauri; Vicente del Valle; Debora Gil; A.Barrios; E.Garcia; Petia Radeva edit  openurl
  Title Perfusion ratio: A new tool to objectively assess microcirculation perfusion after primary Percutaneous Coronary Intervention Type Conference Article
  Year 2006 Publication World Congress of Cardiology Abbreviated Journal  
  Volume Issue Pages 859  
  Keywords  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Barcelona (Spain) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes (up) IAM;MILAB Approved no  
  Call Number IAM @ iam @ RFM2006c Serial 1643  
Permanent link to this record
 

 
Author Oriol Rodriguez-Leon; Josefina Mauri; Eduard Fernandez-Nofrerias; Vicente de Valle; E.Garcia; A.Barrios; Debora Gil; Petia Radeva edit  openurl
  Title Analysis of the changes in angiography local grey-level values to determine myocardial perfusion Type Conference Article
  Year 2006 Publication World Congress of Cardiology Abbreviated Journal  
  Volume Issue Pages 862  
  Keywords  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Barcelona (Spain) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes (up) IAM;MILAB Approved no  
  Call Number IAM @ iam @ RMF2006 Serial 1644  
Permanent link to this record
 

 
Author Misael Rosales; Petia Radeva; Oriol Rodriguez; Debora Gil edit   pdf
doi  openurl
  Title Suppression of IVUS Image Rotation. A Kinematic Approach Type Book Chapter
  Year 2005 Publication Functional Imaging and Modeling of the Heart Abbreviated Journal LNCS  
  Volume 3504 Issue Pages 889-892  
  Keywords  
  Abstract IntraVascular Ultrasound (IVUS) is an exploratory technique used in interventional procedures that shows cross section images of arteries and provides qualitative information about the causes and severity of the arterial lumen narrowing. Cross section analysis as well as visualization of plaque extension in a vessel segment during the catheter imaging pullback are the technique main advantages. However, IVUS sequence exhibits a periodic rotation artifact that makes difficult the longitudinal lesion inspection and hinders any segmentation algorithm. In this paper we propose a new kinematic method to estimate and remove the image rotation of IVUS images sequences. Results on several IVUS sequences show good results and prompt some of the clinical applications to vessel dynamics study, and relation to vessel pathology.  
  Address  
  Corporate Author Thesis  
  Publisher Springer Berlin / Heidelberg Place of Publication Editor Frangi, Alejandro and Radeva, Petia and Santos, Andres and Hernandez, Monica  
  Language Summary Language Original Title  
  Series Editor Series Title Lecture Notes in Computer Science Abbreviated Series Title LNCS  
  Series Volume 3504 Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes (up) IAM;MILAB Approved no  
  Call Number IAM @ iam @ RRR2005 Serial 1645  
Permanent link to this record
 

 
Author Misael Rosales; Petia Radeva;Oriol Rodriguez-Leon; Debora Gil edit   pdf
doi  openurl
  Title Modelling of image-catheter motion for 3-D IVUS Type Journal Article
  Year 2009 Publication Medical image analysis Abbreviated Journal MIA  
  Volume 13 Issue 1 Pages 91-104  
  Keywords Intravascular ultrasound (IVUS); Motion estimation; Motion decomposition; Fourier  
  Abstract Three-dimensional intravascular ultrasound (IVUS) allows to visualize and obtain volumetric measurements of coronary lesions through an exploration of the cross sections and longitudinal views of arteries. However, the visualization and subsequent morpho-geometric measurements in IVUS longitudinal cuts are subject to distortion caused by periodic image/vessel motion around the IVUS catheter. Usually, to overcome the image motion artifact ECG-gating and image-gated approaches are proposed, leading to slowing the pullback acquisition or disregarding part of IVUS data. In this paper, we argue that the image motion is due to 3-D vessel geometry as well as cardiac dynamics, and propose a dynamic model based on the tracking of an elliptical vessel approximation to recover the rigid transformation and align IVUS images without loosing any IVUS data. We report an extensive validation with synthetic simulated data and in vivo IVUS sequences of 30 patients achieving an average reduction of the image artifact of 97% in synthetic data and 79% in real-data. Our study shows that IVUS alignment improves longitudinal analysis of the IVUS data and is a necessary step towards accurate reconstruction and volumetric measurements of 3-D IVUS.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes (up) IAM;MILAB Approved no  
  Call Number IAM @ iam @ RRR2009 Serial 1646  
Permanent link to this record
 

 
Author Oriol Pujol; Debora Gil; Petia Radeva edit   pdf
doi  openurl
  Title Fundamentals of Stop and Go active models Type Journal Article
  Year 2005 Publication Image and Vision Computing Abbreviated Journal  
  Volume 23 Issue 8 Pages 681-691  
  Keywords Deformable models; Geodesic snakes; Region-based segmentation  
  Abstract An efficient snake formulation should conform to the idea of picking the smoothest curve among all the shapes approximating an object of interest. In current geodesic snakes, the regularizing curvature also affects the convergence stage, hindering the latter at concave regions. In the present work, we make use of characteristic functions to define a novel geodesic formulation that decouples regularity and convergence. This term decoupling endows the snake with higher adaptability to non-convex shapes. Convergence is ensured by splitting the definition of the external force into an attractive vector field and a repulsive one. In our paper, we propose to use likelihood maps as approximation of characteristic functions of object appearance. The better efficiency and accuracy of our decoupled scheme are illustrated in the particular case of feature space-based segmentation.  
  Address  
  Corporate Author Thesis  
  Publisher Butterworth-Heinemann Place of Publication Newton, MA, USA Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0262-8856 ISBN Medium  
  Area Expedition Conference  
  Notes (up) IAM;MILAB;HuPBA Approved no  
  Call Number IAM @ iam @ PGR2005 Serial 1629  
Permanent link to this record
 

 
Author Sergio Vera; Debora Gil; Agnes Borras; F. Javier Sanchez; Frederic Perez; Marius G. Linguraru; Miguel Angel Gonzalez Ballester edit   pdf
doi  isbn
openurl 
  Title Computation and Evaluation of Medial Surfaces for Shape Representation of Abdominal Organs Type Book Chapter
  Year 2012 Publication Workshop on Computational and Clinical Applications in Abdominal Imaging Abbreviated Journal  
  Volume 7029 Issue Pages 223–230  
  Keywords medial manifolds, abdomen.  
  Abstract Medial representations are powerful tools for describing and parameterizing the volumetric shape of anatomical structures. Existing methods show excellent results when applied to 2D
objects, but their quality drops across dimensions. This paper contributes to the computation of medial manifolds in two aspects. First, we provide a standard scheme for the computation of medial
manifolds that avoid degenerated medial axis segments; second, we introduce an energy based method which performs independently of the dimension. We evaluate quantitatively the performance of our
method with respect to existing approaches, by applying them to synthetic shapes of known medial geometry. Finally, we show results on shape representation of multiple abdominal organs,
exploring the use of medial manifolds for the representation of multi-organ relations.
 
  Address Toronto; Canada;  
  Corporate Author Thesis  
  Publisher Springer Link Place of Publication Berlin Editor H. Yoshida et al  
  Language English Summary Language English Original Title  
  Series Editor Series Title Lecture Notes in Computer Science Abbreviated Series Title LNCS  
  Series Volume Series Issue Edition  
  ISSN 0302-9743 ISBN 978-3-642-28556-1 Medium  
  Area Expedition Conference ABDI  
  Notes (up) IAM;MV Approved no  
  Call Number IAM @ iam @ VGB2012 Serial 1834  
Permanent link to this record
 

 
Author Carles Sanchez; Debora Gil; Antoni Rosell; Albert Andaluz; F. Javier Sanchez edit   pdf
isbn  openurl
  Title Segmentation of Tracheal Rings in Videobronchoscopy combining Geometry and Appearance Type Conference Article
  Year 2013 Publication Proceedings of the International Conference on Computer Vision Theory and Applications Abbreviated Journal  
  Volume 1 Issue Pages 153--161  
  Keywords Video-bronchoscopy, tracheal ring segmentation, trachea geometric and appearance model  
  Abstract Videobronchoscopy is a medical imaging technique that allows interactive navigation inside the respiratory pathways and minimal invasive interventions. Tracheal procedures are ordinary interventions that require measurement of the percentage of obstructed pathway for injury (stenosis) assessment. Visual assessment of stenosis in videobronchoscopic sequences requires high expertise of trachea anatomy and is prone to human error. Accurate detection of tracheal rings is the basis for automated estimation of the size of stenosed trachea. Processing of videobronchoscopic images acquired at the operating room is a challenging task due to the wide range of artifacts and acquisition conditions. We present a model of the geometric-appearance of tracheal rings for its detection in videobronchoscopic videos. Experiments on sequences acquired at the operating room, show a performance close to inter-observer variability  
  Address Barcelona; February 2013  
  Corporate Author Thesis  
  Publisher SciTePress Place of Publication Portugal Editor Sebastiano Battiato and José Braz  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title LNCS  
  Series Volume Series Issue Edition  
  ISSN ISBN 978-989-8565-47-1 Medium  
  Area 800 Expedition Conference VISAPP  
  Notes (up) IAM;MV; 600.044; 600.047; 600.060; 605.203 Approved no  
  Call Number IAM @ iam @ SGR2013 Serial 2123  
Permanent link to this record
 

 
Author Joan M. Nuñez; Debora Gil; Fernando Vilariño edit  doi
openurl 
  Title Finger joint characterization from X-ray images for rheymatoid arthritis assessment Type Conference Article
  Year 2013 Publication 6th International Conference on Biomedical Electronics and Devices Abbreviated Journal  
  Volume Issue Pages 288-292  
  Keywords Rheumatoid Arthritis; X-Ray; Hand Joint; Sclerosis; Sharp Van der Heijde  
  Abstract In this study we propose amodular systemfor automatic rheumatoid arthritis assessment which provides a joint space width measure. A hand joint model is proposed based on the accurate analysis of a X-ray finger joint image sample set. This model shows that the sclerosis and the lower bone are the main necessary features in order to perform a proper finger joint characterization. We propose sclerosis and lower bone detection methods as well as the experimental setup necessary for its performance assessment. Our characterization is used to propose and compute a joint space width score which is shown to be related to the different degrees of arthritis. This assertion is verified by comparing our proposed score with Sharp Van der Heijde score, confirming that the lower our score is the more advanced is the patient affection.  
  Address Barcelona; February 2013  
  Corporate Author Thesis  
  Publisher SciTePress Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area 800 Expedition Conference BIODEVICES  
  Notes (up) IAM;MV; 600.057; 600.054;SIAI Approved no  
  Call Number IAM @ iam @ NGV2013 Serial 2196  
Permanent link to this record
Select All    Deselect All
 |   | 
Details

Save Citations:
Export Records: