Records |
Links |
|
Author |
Debora Gil; Oriol Rodriguez-Leor; Petia Radeva; Aura Hernandez-Sabate |
|
|
Title |
Assessing Artery Motion Compensation in IVUS |
Type |
Book Chapter |
|
Year |
2007 |
Publication |
Computer Analysis Of Images And Patterns |
Abbreviated Journal |
LNCS |
|
|
Volume |
4673 |
Issue |
|
Pages |
213-220 |
|
|
Keywords |
validation standards; quality measures; IVUS motion compensation; conservation laws; Fourier development |
|
|
Abstract |
Cardiac dynamics suppression is a main issue for visual improvement and computation of tissue mechanical properties in IntraVascular UltraSound (IVUS). Although in recent times several motion compensation techniques have arisen, there is a lack of objective evaluation of motion reduction in in vivo pullbacks. We consider that the assessment protocol deserves special attention for the sake of a clinical applicability as reliable as possible. Our work focuses on defining a quality measure and a validation protocol assessing IVUS motion compensation. On the grounds of continuum mechanics laws we introduce a novel score measuring motion reduction in in vivo sequences. Synthetic experiments validate the proposed score as measure of motion parameters accuracy; while results in in vivo pullbacks show its reliability in clinical cases. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springerlink |
Place of Publication |
Heidelberg |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
Lecture Notes in Computer Science |
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-3-540-74271-5 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GRR2007 |
Serial |
1540 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Petia Radeva |
|
|
Title |
Shape Restoration via a Regularized Curvature Flow |
Type |
Journal Article |
|
Year |
2004 |
Publication |
Journal of Mathematical Imaging and Vision |
Abbreviated Journal |
|
|
|
Volume |
21 |
Issue |
3 |
Pages |
205-223 |
|
|
Keywords |
|
|
|
Abstract |
Any image filtering operator designed for automatic shape restoration should satisfy robustness (whatever the nature and degree of noise is) as well as non-trivial smooth asymptotic behavior. Moreover, a stopping criterion should be determined by characteristics of the evolved image rather than dependent on the number of iterations. Among the several PDE based techniques, curvature flows appear to be highly reliable for strongly noisy images compared to image diffusion processes.
In the present paper, we introduce a regularized curvature flow (RCF) that admits non-trivial steady states. It is based on a measure of the local curve smoothness that takes into account regularity of the curve curvature and serves as stopping term in the mean curvature flow. We prove that this measure decreases over the orbits of RCF, which endows the method with a natural stop criterion in terms of the magnitude of this measure. Further, in its discrete version it produces steady states consisting of piece-wise regular curves. Numerical experiments made on synthetic shapes corrupted with different kinds of noise show the abilities and limitations of each of the current geometric flows and the benefits of RCF. Finally, we present results on real images that illustrate the usefulness of the present approach in practical applications. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GiR2004c |
Serial |
1532 |
|
Permanent link to this record |
|
|
|
|
Author |
Josep Llados; Enric Marti |
|
|
Title |
A graph-edit algorithm for hand-drawn graphical document recognition and their automatic introduction into CAD systems |
Type |
Journal Article |
|
Year |
1999 |
Publication |
Machine Graphics & Vision |
Abbreviated Journal |
|
|
|
Volume |
8 |
Issue |
|
Pages |
195-211 |
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
DAG;IAM; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ LIM1999 |
Serial |
1568 |
|
Permanent link to this record |
|
|
|
|
Author |
Ernest Valveny; Enric Marti |
|
|
Title |
Deformable Template Matching within a Bayesian Framework for Hand-Written Graphic Symbol Recognition |
Type |
Journal Article |
|
Year |
2000 |
Publication |
Graphics Recognition Recent Advances |
Abbreviated Journal |
|
|
|
Volume |
1941 |
Issue |
|
Pages |
193-208 |
|
|
Keywords |
|
|
|
Abstract |
We describe a method for hand-drawn symbol recognition based on deformable template matching able to handle uncertainty and imprecision inherent to hand-drawing. Symbols are represented as a set of straight lines and their deformations as geometric transformations of these lines. Matching, however, is done over the original binary image to avoid loss of information during line detection. It is defined as an energy minimization problem, using a Bayesian framework which allows to combine fidelity to ideal shape of the symbol and flexibility to modify the symbol in order to get the best fit to the binary input image. Prior to matching, we find the best global transformation of the symbol to start the recognition process, based on the distance between symbol lines and image lines. We have applied this method to the recognition of dimensions and symbols in architectural floor plans and we show its flexibility to recognize distorted symbols. |
|
|
Address |
|
|
|
Corporate Author |
Springer Verlag |
Thesis |
|
|
|
Publisher |
Springer Verlag |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
DAG;IAM; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ MVA2000 |
Serial |
1655 |
|
Permanent link to this record |
|
|
|
|
Author |
Petia Radeva; A.Amini; J.Huang; Enric Marti |
|
|
Title |
Deformable B-Solids and Implicit Snakes for Localization and Tracking of SPAMM MRI-Data |
Type |
Conference Article |
|
Year |
1996 |
Publication |
Workshop on Mathematical Methods in Biomedical Image Analysis |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
192-201 |
|
|
Keywords |
|
|
|
Abstract |
To date, MRI-SPAMM data from different image slices have been analyzed independently. In this paper, we propose an approach for 3D tag localization and tracking of SPAMM data by a novel deformable B-solid. The solid is defined in terms of a 3D tensor product B-spline. The isoparametric curves of the B-spline solid have special importance. These are termed implicit snakes as they deform under image forces from tag lines in different image slices. The localization and tracking of tag lines is performed under constraints of continuity and smoothness of the B-solid. The framework unifies the problems of localization, and displacement fitting and interpolation into the same procedure utilizing B-spline bases for interpolation. To track motion from boundaries and restrict image forces to the myocardium, a volumetric model is employed as a pair of coupled endocardial and epicardial B-spline surfaces. To recover deformations in the LV an energy-minimization problem is posed where both tag and ... |
|
|
Address |
San Francisco CA |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
IEEE Computer Society |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
0-8186-7368-0 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
MMBIA ’96 |
|
|
Notes |
MILAB;IAM; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RAH1996 |
Serial |
1630 |
|
Permanent link to this record |
|
|
|
|
Author |
Aura Hernandez-Sabate; Debora Gil |
|
|
Title |
The Benefits of IVUS Dynamics for Retrieving Stable Models of Arteries |
Type |
Book Chapter |
|
Year |
2012 |
Publication |
Intravascular Ultrasound |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
185-206 |
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Intech |
Place of Publication |
|
Editor |
Yasuhiro Honda |
|
|
Language |
English |
Summary Language |
english |
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-953-307-900-4 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; ADAS |
Approved |
no |
|
|
Call Number |
IAM @ iam @ HeG2012 |
Serial |
1684 |
|
Permanent link to this record |
|
|
|
|
Author |
Patricia Marquez; Debora Gil ; Aura Hernandez-Sabate |
|
|
Title |
Error Analysis for Lucas-Kanade Based Schemes |
Type |
Conference Article |
|
Year |
2012 |
Publication |
9th International Conference on Image Analysis and Recognition |
Abbreviated Journal |
|
|
|
Volume |
7324 |
Issue |
I |
Pages |
184-191 |
|
|
Keywords |
Optical flow, Confidence measure, Lucas-Kanade, Cardiac Magnetic Resonance |
|
|
Abstract |
Optical flow is a valuable tool for motion analysis in medical imaging sequences. A reliable application requires determining the accuracy of the computed optical flow. This is a main challenge given the absence of ground truth in medical sequences. This paper presents an error analysis of Lucas-Kanade schemes in terms of intrinsic design errors and numerical stability of the algorithm. Our analysis provides a confidence measure that is naturally correlated to the accuracy of the flow field. Our experiments show the higher predictive value of our confidence measure compared to existing measures. |
|
|
Address |
Aveiro, Portugal |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer-Verlag Berlin Heidelberg |
Place of Publication |
|
Editor |
|
|
|
Language |
english |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
Campilho, Aurélio and Kamel, Mohamed |
Series Title |
Lecture Notes in Computer Science |
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-642-31294-6 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ICIAR |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ MGH2012a |
Serial |
1899 |
|
Permanent link to this record |
|
|
|
|
Author |
Antoni Rosell; Sonia Baeza; S. Garcia-Reina; JL. Mate; Ignasi Guasch; I. Nogueira; I. Garcia-Olive; Guillermo Torres; Carles Sanchez; Debora Gil |
|
|
Title |
EP01.05-001 Radiomics to Increase the Effectiveness of Lung Cancer Screening Programs. Radiolung Preliminary Results |
Type |
Journal Article |
|
Year |
2022 |
Publication |
Journal of Thoracic Oncology |
Abbreviated Journal |
JTO |
|
|
Volume |
17 |
Issue |
9 |
Pages |
S182 |
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
Admin @ si @ RBG2022b |
Serial |
3834 |
|
Permanent link to this record |
|
|
|
|
Author |
Esmitt Ramirez; Carles Sanchez; Agnes Borras; Marta Diez-Ferrer; Antoni Rosell; Debora Gil |
|
|
Title |
BronchoX: bronchoscopy exploration software for biopsy intervention planning |
Type |
Journal |
|
Year |
2018 |
Publication |
Healthcare Technology Letters |
Abbreviated Journal |
HTL |
|
|
Volume |
5 |
Issue |
5 |
Pages |
177–182 |
|
|
Keywords |
|
|
|
Abstract |
Virtual bronchoscopy (VB) is a non-invasive exploration tool for intervention planning and navigation of possible pulmonary lesions (PLs). A VB software involves the location of a PL and the calculation of a route, starting from the trachea, to reach it. The selection of a VB software might be a complex process, and there is no consensus in the community of medical software developers in which is the best-suited system to use or framework to choose. The authors present Bronchoscopy Exploration (BronchoX), a VB software to plan biopsy interventions that generate physician-readable instructions to reach the PLs. The authors’ solution is open source, multiplatform, and extensible for future functionalities, designed by their multidisciplinary research and development group. BronchoX is a compound of different algorithms for segmentation, visualisation, and navigation of the respiratory tract. Performed results are a focus on the test the effectiveness of their proposal as an exploration software, also to measure its accuracy as a guiding system to reach PLs. Then, 40 different virtual planning paths were created to guide physicians until distal bronchioles. These results provide a functional software for BronchoX and demonstrate how following simple instructions is possible to reach distal lesions from the trachea. |
|
|
Address |
|
|
|
Corporate Author |
rank (SJR) |
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; 600.096; 600.075; 601.323; 601.337; 600.145 |
Approved |
no |
|
|
Call Number |
Admin @ si @ RSB2018a |
Serial |
3132 |
|
Permanent link to this record |
|
|
|
|
Author |
Jaume Garcia; David Rotger; Francesc Carreras; R.Leta; Petia Radeva |
|
|
Title |
Contrast echography segmentation and tracking by trained deformable models |
Type |
Conference Article |
|
Year |
2003 |
Publication |
Proc. Computers in Cardiology |
Abbreviated Journal |
|
|
|
Volume |
30 |
Issue |
|
Pages |
173-176 |
|
|
Keywords |
|
|
|
Abstract |
The objective of this work is to segment the human left ventricle myocardium (LVM) in contrast echocardiography imaging and thus track it along a cardiac cycle in order to extract quantitative data about heart function. Ultrasound images are hard to work with due to their speckle appearance. To overcome this we report the combination of active contour models (ACM) or snakes and active shape models (ASM). The ability of ACM in giving closed and smooth curves in addition to the power of the ASM in producing shapes similar to the ones learned, evoke to a robust algorithm. Meanwhile the snake is attracted towards image main features, ASM acts as a correction factor. The algorithm was tested independently on 180 frames and satisfying results were obtained: in 95% the maximum difference between automatic and experts segmentation was less than 12 pixels. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Centre de Visió per Computador – Dept. Informàtica, UAB Edifici O – Campus UAB, 08193 Bellater |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0276-6547 |
ISBN |
0-7803-8170-X |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GRC2003 |
Serial |
1512 |
|
Permanent link to this record |