Sonia Baeza, Debora Gil, I.Garcia Olive, M.Salcedo, J.Deportos, Carles Sanchez, et al. (2022). "A novel intelligent radiomic analysis of perfusion SPECT/CT images to optimize pulmonary embolism diagnosis in COVID-19 patients " . EJNMMI Physics, 9(1, Article 84), 1–17.
Abstract: Background: COVID-19 infection, especially in cases with pneumonia, is associated with a high rate of pulmonary embolism (PE). In patients with contraindications for CT pulmonary angiography (CTPA) or non-diagnostic CTPA, perfusion single-photon emission computed tomography/computed tomography (Q-SPECT/CT) is a diagnostic alternative. The goal of this study is to develop a radiomic diagnostic system to detect PE based only on the analysis of Q-SPECT/CT scans.
Methods: This radiomic diagnostic system is based on a local analysis of Q-SPECT/CT volumes that includes both CT and Q-SPECT values for each volume point. We present a combined approach that uses radiomic features extracted from each scan as input into a fully connected classifcation neural network that optimizes a weighted crossentropy loss trained to discriminate between three diferent types of image patterns (pixel sample level): healthy lungs (control group), PE and pneumonia. Four types of models using diferent confguration of parameters were tested.
Results: The proposed radiomic diagnostic system was trained on 20 patients (4,927 sets of samples of three types of image patterns) and validated in a group of 39 patients (4,410 sets of samples of three types of image patterns). In the training group, COVID-19 infection corresponded to 45% of the cases and 51.28% in the test group. In the test group, the best model for determining diferent types of image patterns with PE presented a sensitivity, specifcity, positive predictive value and negative predictive value of 75.1%, 98.2%, 88.9% and 95.4%, respectively. The best model for detecting
pneumonia presented a sensitivity, specifcity, positive predictive value and negative predictive value of 94.1%, 93.6%, 85.2% and 97.6%, respectively. The area under the curve (AUC) was 0.92 for PE and 0.91 for pneumonia. When the results obtained at the pixel sample level are aggregated into regions of interest, the sensitivity of the PE increases to 85%, and all metrics improve for pneumonia.
Conclusion: This radiomic diagnostic system was able to identify the diferent lung imaging patterns and is a frst step toward a comprehensive intelligent radiomic system to optimize the diagnosis of PE by Q-SPECT/CT.
|
|
|
Oriol Rodriguez-Leor, A. Carol, H. Tizon, Eduard Fernandez-Nofrerias, Josefina Mauri, Vicente del Valle, et al. (2005)." Model estadístic-determinístic per la segmentació de l adventicia en imatges d ecografía intracoronaria" . Rev Societat Catalana Cardiologia, 5, 41.
|
|
|
Oriol Rodriguez-Leor, Josefina Mauri, Eduard Fernandez-Nofrerias, M. Gomez, Antonio Tovar, L. Cano, et al. (2002)." Ecografia Intracoronaria: Segmentacio Automatica de area de la llum" . Revista Societat Catalana de Cardiologia, 4(4), 42.
|
|
|
Aura Hernandez-Sabate, Debora Gil, Jaume Garcia, & Enric Marti. (2011). "Image-based Cardiac Phase Retrieval in Intravascular Ultrasound Sequences " . IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 58(1), 60–72.
Abstract: Longitudinal motion during in vivo pullbacks acquisition of intravascular ultrasound (IVUS) sequences is a major artifact for 3-D exploring of coronary arteries. Most current techniques are based on the electrocardiogram (ECG) signal to obtain a gated pullback without longitudinal motion by using specific hardware or the ECG signal itself. We present an image-based approach for cardiac phase retrieval from coronary IVUS sequences without an ECG signal. A signal reflecting cardiac motion is computed by exploring the image intensity local mean evolution. The signal is filtered by a band-pass filter centered at the main cardiac frequency. Phase is retrieved by computing signal extrema. The average frame processing time using our setup is 36 ms. Comparison to manually sampled sequences encourages a deeper study comparing them to ECG signals.
Keywords: 3-D exploring; ECG; band-pass filter; cardiac motion; cardiac phase retrieval; coronary arteries; electrocardiogram signal; image intensity local mean evolution; image-based cardiac phase retrieval; in vivo pullbacks acquisition; intravascular ultrasound sequences; longitudinal motion; signal extrema; time 36 ms; band-pass filters; biomedical ultrasonics; cardiovascular system; electrocardiography; image motion analysis; image retrieval; image sequences; medical image processing; ultrasonic imaging
|
|
|
Debora Gil, Rosa Maria Ortiz, Carles Sanchez, & Antoni Rosell. (2018). "Objective endoscopic measurements of central airway stenosis. A pilot study " . Respiration, 95, 63–69.
Abstract: Endoscopic estimation of the degree of stenosis in central airway obstruction is subjective and highly variable. Objective: To determine the benefits of using SENSA (System for Endoscopic Stenosis Assessment), an image-based computational software, for obtaining objective stenosis index (SI) measurements among a group of expert bronchoscopists and general pulmonologists. Methods: A total of 7 expert bronchoscopists and 7 general pulmonologists were enrolled to validate SENSA usage. The SI obtained by the physicians and by SENSA were compared with a reference SI to set their precision in SI computation. We used SENSA to efficiently obtain this reference SI in 11 selected cases of benign stenosis. A Web platform with three user-friendly microtasks was designed to gather the data. The users had to visually estimate the SI from videos with and without contours of the normal and the obstructed area provided by SENSA. The users were able to modify the SENSA contours to define the reference SI using morphometric bronchoscopy. Results: Visual SI estimation accuracy was associated with neither bronchoscopic experience (p = 0.71) nor the contours of the normal and the obstructed area provided by the system (p = 0.13). The precision of the SI by SENSA was 97.7% (95% CI: 92.4-103.7), which is significantly better than the precision of the SI by visual estimation (p < 0.001), with an improvement by at least 15%. Conclusion: SENSA provides objective SI measurements with a precision of up to 99.5%, which can be calculated from any bronchoscope using an affordable scalable interface. Providing normal and obstructed contours on bronchoscopic videos does not improve physicians' visual estimation of the SI.
Keywords: Bronchoscopy; Tracheal stenosis; Airway stenosis; Computer-assisted analysis
|
|
|
Debora Gil, Ruth Aris, Agnes Borras, Esmitt Ramirez, Rafael Sebastian, & Mariano Vazquez. (2019). "Influence of fiber connectivity in simulations of cardiac biomechanics " . International Journal of Computer Assisted Radiology and Surgery, 14(1), 63–72.
Abstract: PURPOSE:
Personalized computational simulations of the heart could open up new improved approaches to diagnosis and surgery assistance systems. While it is fully recognized that myocardial fiber orientation is central for the construction of realistic computational models of cardiac electromechanics, the role of its overall architecture and connectivity remains unclear. Morphological studies show that the distribution of cardiac muscular fibers at the basal ring connects epicardium and endocardium. However, computational models simplify their distribution and disregard the basal loop. This work explores the influence in computational simulations of fiber distribution at different short-axis cuts.
METHODS:
We have used a highly parallelized computational solver to test different fiber models of ventricular muscular connectivity. We have considered two rule-based mathematical models and an own-designed method preserving basal connectivity as observed in experimental data. Simulated cardiac functional scores (rotation, torsion and longitudinal shortening) were compared to experimental healthy ranges using generalized models (rotation) and Mahalanobis distances (shortening, torsion).
RESULTS:
The probability of rotation was significantly lower for ruled-based models [95% CI (0.13, 0.20)] in comparison with experimental data [95% CI (0.23, 0.31)]. The Mahalanobis distance for experimental data was in the edge of the region enclosing 99% of the healthy population.
CONCLUSIONS:
Cardiac electromechanical simulations of the heart with fibers extracted from experimental data produce functional scores closer to healthy ranges than rule-based models disregarding architecture connectivity.
Keywords: Cardiac electromechanical simulations; Diffusion tensor imaging; Fiber connectivity
|
|
|
Mireia Sole, Joan Blanco, Debora Gil, G. Fonseka, Richard Frodsham, Francesca Vidal, et al. (2017). "Noves perspectives en l estudi de la territorialitat cromosomica de cel·lules germinals masculines: estudis tridimensionals " . Biologia de la Reproduccio, 15, 73–78.
Abstract: In somatic cells, chromosomes occupy specific nuclear regions called chromosome territories which are involved in the
maintenance and regulation of the genome. Preliminary data in male germ cells also suggest the importance of chromosome
territoriality in cell functionality. Nevertheless, the specific characteristics of testicular tissue (presence of different
cell types with different morphological characteristics, in different stages of development and with different ploidy)
makes difficult to achieve conclusive results. In this study we have developed a methodology to approach the threedimensional
study of all chromosome territories in male germ cells from C57BL/6J mice (Mus musculus). The method
includes the following steps: i) Optimized cell fixation to obtain an optimal preservation of the three-dimensionality cell
morphology, ii) Chromosome identification by FISH (Chromoprobe Multiprobe® OctoChrome™ Murine System; Cytocell)
and confocal microscopy (TCS-SP5, Leica Microsystems), iii) Cell type identification by immunofluorescence
iv) Image analysis using Matlab scripts, v) Numerical data extraction related to chromosome features, chromosome
radial position and chromosome relative position. This methodology allows the unequivocally identification and the
analysis of the chromosome territories of all spermatogenic stages. Results will provide information about the features
that determine chromosomal position, preferred associations between chromosomes, and the relationship between chromosome
positioning and genome regulation.
|
|
|
Jaume Garcia, Debora Gil, Sandra Pujades, & Francesc Carreras. (2008). "A Variational Framework for Assessment of the Left Ventricle Motion " . International Journal Mathematical Modelling of Natural Phenomena, 3(6), 76–100.
Abstract: Impairment of left ventricular contractility due to cardiovascular diseases is reflected in left ventricle (LV) motion patterns. An abnormal change of torsion or long axis shortening LV values can help with the diagnosis and follow-up of LV dysfunction. Tagged Magnetic Resonance (TMR) is a widely spread medical imaging modality that allows estimation of the myocardial tissue local deformation. In this work, we introduce a novel variational framework for extracting the left ventricle dynamics from TMR sequences. A bi-dimensional representation space of TMR images given by Gabor filter banks is defined. Tracking of the phases of the Gabor response is combined using a variational framework which regularizes the deformation field just at areas where the Gabor amplitude drops, while restoring the underlying motion otherwise. The clinical applicability of the proposed method is illustrated by extracting normality models of the ventricular torsion from 19 healthy subjects.
Keywords: Key words: Left Ventricle Dynamics, Ventricular Torsion, Tagged Magnetic Resonance, Motion Tracking, Variational Framework, Gabor Transform.
|
|
|
H. Martin Kjer, Jens Fagertuna, Sergio Vera, Debora Gil, Miguel Angel Gonzalez Ballester, & Rasmus R. Paulsena. (2016). "Free-form image registration of human cochlear uCT data using skeleton similarity as anatomical prior " . Patter Recognition Letters, 76(1), 76–82.
|
|
|
Jaume Garcia, Debora Gil, Sandra Pujades, & Francesc Carreras. (2008). "Valoracion de la Funcion del Ventriculo Izquierdo mediante Modelos Regionales Hiperparametricos " . Revista Española de Cardiologia, 61(3), 79.
Abstract: La mayoría de la enfermedades cardiovasculares afectan a las propiedades contráctiles de la banda ventricular helicoidal. Esto se refleja en una variación del comportamiento normal de la función ventricular. Parámetros locales tales como los strains, o la deformación experimentada por el tejido, son indicadores capaces de detectar anomalías funcionales en territorios específicos. A menudo, dichos parámetros son considerados de forma separada. En este trabajo presentamos un marco computacional (el Dominio Paramétrico Normalizado, DPN) que permite integrarlos en hiperparámetros funcionales y estudiar sus rangos de normalidad. Dichos rangos permiten valorar de forma objetiva la función regional de cualquier nuevo paciente. Para ello, consideramos secuencias de resonancia magnética etiquetada a nivel basal, medio y apical. Los hiperparámetros se obtienen a partir del movimiento intramural del VI estimado mediante el método Harmonic Phase Flow. El DPN se define a partir de en una parametrización del Ventrículo Izquierdo (VI) en sus coordenadas radiales y circunferencial basada en criterios anatómicos. El paso de los hiperparámetros al DPN hace posible la comparación entre distintos pacientes. Los rangos de normalidad se definen mediante análisis estadístico de valores de voluntarios sanos en 45 regiones del DPN a lo largo de 9 fases sistólicas. Se ha usado un conjunto de 19 (14 H; E: 30.7±7.5) voluntarios sanos para crear los patrones de normalidad y se han validado usando 2 controles sanos y 3 pacientes afectados de contractilidad global reducida. Para los controles los resultados regionales se han ajustado dentro de la normalidad, mientras que para los pacientes se han obtenido valores anormales en las zonas descritas, localizando y cuantificando así el diagnóstico empírico.
|
|