|
H. Martin Kjer, Jens Fagertun, Sergio Vera, & Debora Gil. (2017). "Medial structure generation for registration of anatomical structures " In Skeletonization, Theory, Methods and Applications (Vol. 11).
|
|
|
H. Martin Kjer, Jens Fagertun, Sergio Vera, Debora Gil, Miguel Angel Gonzalez Ballester, & Rasmus R. Paulsena. (2016). "Free-form image registration of human cochlear uCT data using skeleton similarity as anatomical prior " . Patter Recognition Letters, 76(1), 76–82.
|
|
|
Enric Marti, Antoni Gurgui, Debora Gil, Aura Hernandez-Sabate, Jaume Rocarias, & Ferran Poveda. (2014). "ABP on line: Seguimiento, estregas y evaluación en aprendizaje basado en proyectos ".
|
|
|
Patricia Marquez, Debora Gil, & Aura Hernandez-Sabate. (2013). "Evaluation of the Capabilities of Confidence Measures for Assessing Optical Flow Quality " In ICCV Workshop on Computer Vision in Vehicle Technology: From Earth to Mars (pp. 624–631).
Abstract: Assessing Optical Flow (OF) quality is essential for its further use in reliable decision support systems. The absence of ground truth in such situations leads to the computation of OF Confidence Measures (CM) obtained from either input or output data. A fair comparison across the capabilities of the different CM for bounding OF error is required in order to choose the best OF-CM pair for discarding points where OF computation is not reliable. This paper presents a statistical probabilistic framework for assessing the quality of a given CM. Our quality measure is given in terms of the percentage of pixels whose OF error bound can not be determined by CM values. We also provide statistical tools for the computation of CM values that ensures a given accuracy of the flow field.
|
|
|
Patricia Marquez, Debora Gil, R.Mester, & Aura Hernandez-Sabate. (2014). "Local Analysis of Confidence Measures for Optical Flow Quality Evaluation " In 9th International Conference on Computer Vision Theory and Applications (Vol. 3, pp. 450–457).
Abstract: Optical Flow (OF) techniques facing the complexity of real sequences have been developed in the last years. Even using the most appropriate technique for our specific problem, at some points the output flow might fail to achieve the minimum error required for the system. Confidence measures computed from either input data or OF output should discard those points where OF is not accurate enough for its further use. It follows that evaluating the capabilities of a confidence measure for bounding OF error is as important as the definition
itself. In this paper we analyze different confidence measures and point out their advantages and limitations for their use in real world settings. We also explore the agreement with current tools for their evaluation of confidence measures performance.
Keywords: Optical Flow; Confidence Measure; Performance Evaluation.
|
|
|
Patricia Marquez, H. Kause, A. Fuster, Aura Hernandez-Sabate, L. Florack, Debora Gil, et al. (2014). "Factors Affecting Optical Flow Performance in Tagging Magnetic Resonance Imaging " In 17th International Conference on Medical Image Computing and Computer Assisted Intervention (Vol. 8896, pp. 231–238). Springer International Publishing.
Abstract: Changes in cardiac deformation patterns are correlated with cardiac pathologies. Deformation can be extracted from tagging Magnetic Resonance Imaging (tMRI) using Optical Flow (OF) techniques. For applications of OF in a clinical setting it is important to assess to what extent the performance of a particular OF method is stable across dierent clinical acquisition artifacts. This paper presents a statistical validation framework, based on ANOVA, to assess the motion and appearance factors that have the largest in uence on OF accuracy drop.
In order to validate this framework, we created a database of simulated tMRI data including the most common artifacts of MRI and test three dierent OF methods, including HARP.
Keywords: Optical flow; Performance Evaluation; Synthetic Database; ANOVA; Tagging Magnetic Resonance Imaging
|
|
|
Enric Marti, Ferran Poveda, Antoni Gurgui, Jaume Rocarias, & Debora Gil. (2013). "Una propuesta de seguimiento, tutorías on line y evaluación en la metodología de Aprendizaje Basado en Proyectos ".
|
|
|
Enric Marti, Ferran Poveda, Antoni Gurgui, Jaume Rocarias, Debora Gil, & Aura Hernandez-Sabate. (2013). "Una experiencia de estructura, funcionamiento y evaluación de la asignatura de graficos por computador con metodologia de aprendizaje basado en proyectos ".
Abstract: IV Congreso Internacional UNIVEST
|
|
|
Enric Marti, J.Roncaries, Debora Gil, Aura Hernandez-Sabate, Antoni Gurgui, & Ferran Poveda. (2015). "PBL On Line: A proposal for the organization, part-time monitoring and assessment of PBL group activities " . Journal of Technology and Science Education, 5(2), 87–96.
|
|
|
Rosa Maria Ortiz, Debora Gil, Elisa Minchole, Marta Diez-Ferrer, & Noelia Cubero de Frutos. (2017). "Classification of Confolcal Endomicroscopy Patterns for Diagnosis of Lung Cancer " In 18th World Conference on Lung Cancer.
Abstract: Confocal Laser Endomicroscopy (CLE) is an emerging imaging technique that allows the in-vivo acquisition of cell patterns of potentially malignant lesions. Such patterns could discriminate between inflammatory and neoplastic lesions and, thus, serve as a first in-vivo biopsy to discard cases that do not actually require a cell biopsy.
The goal of this work is to explore whether CLE images obtained during videobronchoscopy contain enough visual information to discriminate between benign and malign peripheral lesions for lung cancer diagnosis. To do so, we have performed a pilot comparative study with 12 patients (6 adenocarcinoma and 6 benign-inflammatory) using 2 different methods for CLE pattern analysis: visual analysis by 3 experts and a novel methodology that uses graph methods to find patterns in pre-trained feature spaces. Our preliminary results indicate that although visual analysis can only achieve a 60.2% of accuracy, the accuracy of the proposed unsupervised image pattern classification raises to 84.6%.
We conclude that CLE images visual information allow in-vivo detection of neoplastic lesions and graph structural analysis applied to deep-learning feature spaces can achieve competitive results.
|
|