|
Carles Fernandez, Pau Baiget, Xavier Roca, & Jordi Gonzalez. (2008). Interpretation of Complex Situations in a Semantic-based Surveillance Framework. Signal Processing: Image Communication, Special Issue on Semantic Analysis for Interactive Multimedia Services, 554–569.
Abstract: The integration of cognitive capabilities in computer vision systems requires both to enable high semantic expressiveness and to deal with high computational costs as large amounts of data are involved in the analysis. This contribution describes a cognitive vision system conceived to automatically provide high-level interpretations of complex real-time situations in outdoor and indoor scenarios, and to eventually maintain communication with casual end users in multiple languages. The main contributions are: (i) the design of an integrative multilevel architecture for cognitive surveillance purposes; (ii) the proposal of a coherent taxonomy of knowledge to guide the process of interpretation, which leads to the conception of a situation-based ontology; (iii) the use of situational analysis for content detection and a progressive interpretation of semantically rich scenes, by managing incomplete or uncertain knowledge, and (iv) the use of such an ontological background to enable multilingual capabilities and advanced end-user interfaces. Experimental results are provided to show the feasibility of the proposed approach.
Keywords: Cognitive vision system; Situation analysis; Applied ontologies
|
|
|
Debora Gil, Oriol Rodriguez-Leor, Petia Radeva, & J. Mauri. (2008). Myocardial Perfusion Characterization From Contrast Angiography Spectral Distribution. IEEE Transactions on Medical Imaging, 27(5), 641–649.
Abstract: Despite recovering a normal coronary flow after acute myocardial infarction, percutaneous coronary intervention does not guarantee a proper perfusion (irrigation) of the infarcted area. This damage in microcirculation integrity may detrimentally affect the patient survival. Visual assessment of the myocardium opacification in contrast angiography serves to define a subjective score of the microcirculation integrity myocardial blush analysis (MBA). Although MBA correlates with patient prognosis its visual assessment is a very difficult task that requires of a highly expertise training in order to achieve a good intraobserver and interobserver agreement. In this paper, we provide objective descriptors of the myocardium staining pattern by analyzing the spectrum of the image local statistics. The descriptors proposed discriminate among the different phenomena observed in the angiographic sequence and allow defining an objective score of the myocardial perfusion.
Keywords: Contrast angiography; myocardial perfusion; spectral analysis.
|
|
|
Sandra Pujades, Francesc Carreras, Manuel Ballester, Jaume Garcia, & Debora Gil. (2008). A Normalized Parametric Domain for the Analysis of the Left Ventricular Function. In Proceedings of the Third International Conference on Computer Vision Theory and Applications (VISAPP’08) (Vol. 1, pp. 267–274).
Abstract: Impairment of left ventricular (LV) contractility due to cardiovascular diseases is reflected in LV motion patterns. The mechanics of any muscle strongly depends on the spatial orientation of its muscular fibers since the motion that the muscle undergoes mainly takes place along the fiber. The helical ventricular myocardial band (HVMB) concept describes the myocardial muscle as a unique muscular band that twists in space in a non homogeneous fashion. The 3D anisotropy of the ventricular band fibers suggests a regional analysis of the heart motion. Computation of normality models of such motion can help in the detection and localization of any cardiac disorder. In this paper we introduce, for the first time, a normalized parametric domain that allows comparison of the left ventricle motion across patients. We address, both, extraction of the LV motion from Tagged Magnetic Resonance images, as well as, defining a mapping of the LV to a common normalized domain. Extraction of normality motion patterns from 17 healthy volunteers shows the clinical potential of our LV parametrization.
Keywords: Helical Ventricular Myocardial Band; Myocardial Fiber; Tagged Magnetic Resonance; HARP; Optical Flow Variational Framework; Gabor Filters; B-Splines.
|
|
|
David Vazquez, & Antonio Lopez. (2008). Intrusion Classification in Intelligent Video Surveillance Systems.
Abstract: An intelligent video surveillance system (IVS) is a camera-based installation able to process in real-time the images coming from the cameras. The aim is to automatically warn about different events of interest at the moment they happen. Daview system of Davantis is a com mercial example of IVS system. The problems addressed by any IVS system, and so Daview, are so challenging that none IVS system is perfect, thus, they need continuous improvement. Accordingly, this project aims to study different approaches in order to outperform current Daview performance, in particular, we bet for improving its classification core. We present an in deep study of the state of the art on IVS systems, as well as on how Daview works. Based on that knowledge, we propose four possibilities for improving Daview classification capabilities: improve existent classifiers; improve existing classifiers combination; create new classifiers and create new classifier-based architectures. Our main contribution has been the incorporation of state-of-the-art feature selection and machine learning techniques for the classification tasks, a viewpoint not fully addressed in current Daview system. After a comprehensive quantitative evaluation we will see how one of our proposals clearly outperforms the overall performance of current Daview system. In particular the classification core that we finally propose consists in an AdaBoost One-Against-All architecture that uses appearance and motion features that were already present in current Daview system
Keywords: Human detection; Car detection; Intrusion detection
|
|
|
Antonio Lopez, J. Hilgenstock, A. Busse, Ramon Baldrich, Felipe Lumbreras, & Joan Serrat. (2008). Temporal Coherence Analysis for Intelligent Headlight Control.
Keywords: Intelligent Headlights
|
|
|
Antonio Lopez, J. Hilgenstock, A. Busse, Ramon Baldrich, Felipe Lumbreras, & Joan Serrat. (2008). Nightime Vehicle Detecion for Intelligent Headlight Control. In Advanced Concepts for Intelligent Vision Systems, 10th International Conference, Proceedings, (Vol. 5259, 113–124). LNCS.
Keywords: Intelligent Headlights; vehicle detection
|
|
|
Jaume Garcia, Debora Gil, Sandra Pujades, & Francesc Carreras. (2008). A Variational Framework for Assessment of the Left Ventricle Motion. International Journal Mathematical Modelling of Natural Phenomena, 3(6), 76–100.
Abstract: Impairment of left ventricular contractility due to cardiovascular diseases is reflected in left ventricle (LV) motion patterns. An abnormal change of torsion or long axis shortening LV values can help with the diagnosis and follow-up of LV dysfunction. Tagged Magnetic Resonance (TMR) is a widely spread medical imaging modality that allows estimation of the myocardial tissue local deformation. In this work, we introduce a novel variational framework for extracting the left ventricle dynamics from TMR sequences. A bi-dimensional representation space of TMR images given by Gabor filter banks is defined. Tracking of the phases of the Gabor response is combined using a variational framework which regularizes the deformation field just at areas where the Gabor amplitude drops, while restoring the underlying motion otherwise. The clinical applicability of the proposed method is illustrated by extracting normality models of the ventricular torsion from 19 healthy subjects.
Keywords: Key words: Left Ventricle Dynamics, Ventricular Torsion, Tagged Magnetic Resonance, Motion Tracking, Variational Framework, Gabor Transform.
|
|
|
Francisco Javier Orozco, Xavier Roca, & Jordi Gonzalez. (2008). Real-Time Gaze Tracking with Appearance-Based Models. MVAP - Machine Vision Applications, 20(6), 353–364.
Abstract: Psychological evidence has emphasized the importance of eye gaze analysis in human computer interaction and emotion interpretation. To this end, current image analysis algorithms take into consideration eye-lid and iris motion detection using colour information and edge detectors. However, eye movement is fast and and hence difficult to use to obtain a precise and robust tracking. Instead, our
method proposed to describe eyelid and iris movements as continuous variables using appearance-based tracking. This approach combines the strengths of adaptive appearance models, optimization methods and backtracking techniques.Thus,
in the proposed method textures are learned on-line from near frontal images and illumination changes, occlusions and fast movements are managed. The method achieves real-time performance by combining two appearance-based trackers to a
backtracking algorithm for eyelid estimation and another for iris estimation. These contributions represent a significant advance towards a reliable gaze motion description for HCI and expression analysis, where the strength of complementary
methodologies are combined to avoid using high quality images, colour information, texture training, camera settings and other time-consuming processes.
Keywords: Keywords Eyelid and iris tracking, Appearance models, Blinking, Iris saccade, Real-time gaze tracking
|
|
|
Debora Gil, Jaume Garcia, Mariano Vazquez, Ruth Aris, & Guilleaume Houzeaux. (2008). Patient-Sensitive Anatomic and Functional 3D Model of the Left Ventricle Function. In 8th World Congress on Computational Mechanichs (WCCM8).
Abstract: Early diagnosis and accurate treatment of Left Ventricle (LV) dysfunction significantly increases the patient survival. Impairment of LV contractility due to cardiovascular diseases is reflected in its motion patterns. Recent advances in medical imaging, such as Magnetic Resonance (MR), have encouraged research on 3D simulation and modelling of the LV dynamics. Most of the existing 3D models [1] consider just the gross anatomy of the LV and restore a truncated ellipse which deforms along the cardiac cycle. The contraction mechanics of any muscle strongly depends on the spatial orientation of its muscular fibers since the motion that the muscle undergoes mainly takes place along the fibers. It follows that such simplified models do not allow evaluation of the heart electro-mechanical function and coupling, which has recently risen as the key point for understanding the LV functionality [2]. In order to thoroughly understand the LV mechanics it is necessary to consider the complete anatomy of the LV given by the orientation of the myocardial fibres in 3D space as described by Torrent Guasp [3].
We propose developing a 3D patient-sensitive model of the LV integrating, for the first time, the ven- tricular band anatomy (fibers orientation), the LV gross anatomy and its functionality. Such model will represent the LV function as a natural consequence of its own ventricular band anatomy. This might be decisive in restoring a proper LV contraction in patients undergoing pace marker treatment.
The LV function is defined as soon as the propagation of the contractile electromechanical pulse has been modelled. In our experiments we have used the wave equation for the propagation of the electric pulse. The electromechanical wave moves on the myocardial surface and should have a conductivity tensor oriented along the muscular fibers. Thus, whatever mathematical model for electric pulse propa- gation [4] we consider, the complete anatomy of the LV should be extracted.
The LV gross anatomy is obtained by processing multi slice MR images recorded for each patient. Information about the myocardial fibers distribution can only be extracted by Diffusion Tensor Imag- ing (DTI), which can not provide in vivo information for each patient. As a first approach, we have
Figure 1: Scheme for the Left Ventricle Patient-Sensitive Model.
computed an average model of fibers from several DTI studies of canine hearts. This rough anatomy is the input for our electro-mechanical propagation model simulating LV dynamics. The average fiber orientation is updated until the simulated LV motion agrees with the experimental evidence provided by the LV motion observed in tagged MR (TMR) sequences. Experimental LV motion is recovered by applying image processing, differential geometry and interpolation techniques to 2D TMR slices [5]. The pipeline in figure 1 outlines the interaction between simulations and experimental data leading to our patient-tailored model.
Keywords: Left Ventricle, Electromechanical Models, Image Processing, Magnetic Resonance.
|
|
|
Debora Gil, Jaume Garcia, Manuel Vazquez, Ruth Aris, & Guillaume Houzeaux. (2008). Patient-Sensitive Anatomic and Functional 3D Model of the Left Ventricle Function. In 8th World Congress on Computational Mechanichs (WCCM8)/5th European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2008). Venezia (Italia).
Abstract: Early diagnosis and accurate treatment of Left Ventricle (LV) dysfunction significantly increases the patient survival. Impairment of LV contractility due to cardiovascular diseases is reflected in its motion patterns. Recent advances in medical imaging, such as Magnetic Resonance (MR), have encouraged research on 3D simulation and modelling of the LV dynamics. Most of the existing 3D models consider just the gross anatomy of the LV and restore a truncated ellipse which deforms along the cardiac cycle. The contraction mechanics of any muscle strongly depends on the spatial orientation of its muscular fibers since the motion that the muscle undergoes mainly takes place along the fibers. It follows that such simplified models do not allow evaluation of the heart electro-mechanical function and coupling, which has recently risen as the key point for understanding the LV functionality . In order to thoroughly understand the LV mechanics it is necessary to consider the complete anatomy of the LV given by the orientation of the myocardial fibres in 3D space as described by Torrent Guasp. We propose developing a 3D patient-sensitive model of the LV integrating, for the first time, the ven- tricular band anatomy (fibers orientation), the LV gross anatomy and its functionality. Such model will represent the LV function as a natural consequence of its own ventricular band anatomy. This might be decisive in restoring a proper LV contraction in patients undergoing pace marker treatment. The LV function is defined as soon as the propagation of the contractile electromechanical pulse has been modelled. In our experiments we have used the wave equation for the propagation of the electric pulse. The electromechanical wave moves on the myocardial surface and should have a conductivity tensor oriented along the muscular fibers. Thus, whatever mathematical model for electric pulse propa- gation [4] we consider, the complete anatomy of the LV should be extracted. The LV gross anatomy is obtained by processing multi slice MR images recorded for each patient. Information about the myocardial fibers distribution can only be extracted by Diffusion Tensor Imag- ing (DTI), which can not provide in vivo information for each patient. As a first approach, we have computed an average model of fibers from several DTI studies of canine hearts. This rough anatomy is the input for our electro-mechanical propagation model simulating LV dynamics. The average fiber orientation is updated until the simulated LV motion agrees with the experimental evidence provided by the LV motion observed in tagged MR (TMR) sequences. Experimental LV motion is recovered by applying image processing, differential geometry and interpolation techniques to 2D TMR slices [5]. The pipeline in figure 1 outlines the interaction between simulations and experimental data leading to our patient-tailored model.
Keywords: Left Ventricle; Electromechanical Models; Image Processing; Magnetic Resonance.
|
|
|
Aura Hernandez-Sabate, David Rotger, & Debora Gil. (2008). Image-based ECG sampling of IVUS sequences. In Proc. IEEE Ultrasonics Symp. IUS 2008 (pp. 1330–1333).
Abstract: Longitudinal motion artifacts in IntraVascular UltraSound (IVUS) sequences hinders a properly 3D reconstruction and vessel measurements. Most of current techniques base on the ECG signal to obtain a gated pullback without the longitudinal artifact by using a specific hardware or the ECG signal itself. The potential of IVUS images processing for phase retrieval still remains little explored. In this paper, we present a fast forward image-based algorithm to approach ECG sampling. Inspired on the fact that maximum and minimum lumen areas are related to end-systole and end-diastole, our cardiac phase retrieval is based on the analysis of tissue density of mass along the sequence. The comparison between automatic and manual phase retrieval (0.07 ± 0.07 mm. of error) encourages a deep validation contrasting with ECG signals.
Keywords: Longitudinal Motion; Image-based ECG-gating; Fourier analysis
|
|
|
Josep Llados, Dimosthenis Karatzas, Joan Mas, & Gemma Sanchez. (2008). A Generic Architecture for the Conversion of Document Collections into Semantically Annotated Digital Archives. Journal of Universal Computer Science, 2912–2935.
Keywords: Median Graph, Graph Embedding, Graph Matching, Structural Pattern Recognition
|
|
|
Jose Manuel Alvarez, Antonio Lopez, & Ramon Baldrich. (2008). Illuminant Invariant Model-Based Road Segmentation. In IEEE Intelligent Vehicles Symposium, (1155–1180).
|
|
|
Jose Manuel Alvarez, & Antonio Lopez. (2008). Novel Index for Objective Evaluation of Road Detection Algorithms. In Intelligent Transportation Systems. 11th International IEEE Conference on, (815–820).
|
|
|
Joan Serrat, Ferran Diego, Felipe Lumbreras, Jose Manuel Alvarez, Antonio Lopez, & C. Elvira. (2008). Dynamic Comparison of Headlights. Journal of Automobile Engineering, 222(5), 643–656.
Keywords: video alignment
|
|