|
Ernest Valveny, Robert Benavente, Agata Lapedriza, Miquel Ferrer, Jaume Garcia, & Gemma Sanchez. (2012). Adaptation of a computer programming course to the EXHE requirements: evaluation five years later (Vol. 37).
|
|
|
Alicia Fornes, Anjan Dutta, Albert Gordo, & Josep Llados. (2012). CVC-MUSCIMA: A Ground-Truth of Handwritten Music Score Images for Writer Identification and Staff Removal. IJDAR - International Journal on Document Analysis and Recognition, 15(3), 243–251.
Abstract: 0,405JCR
The analysis of music scores has been an active research field in the last decades. However, there are no publicly available databases of handwritten music scores for the research community. In this paper we present the CVC-MUSCIMA database and ground-truth of handwritten music score images. The dataset consists of 1,000 music sheets written by 50 different musicians. It has been especially designed for writer identification and staff removal tasks. In addition to the description of the dataset, ground-truth, partitioning and evaluation metrics, we also provide some base-line results for easing the comparison between different approaches.
Keywords: Music scores; Handwritten documents; Writer identification; Staff removal; Performance evaluation; Graphics recognition; Ground truths
|
|
|
Debora Gil, Agnes Borras, Ruth Aris, Mariano Vazquez, Pierre Lafortune, & Guillame Houzeaux. (2012). What a difference in biomechanics cardiac fiber makes. In Statistical Atlases And Computational Models Of The Heart: Imaging and Modelling Challenges (Vol. 7746, pp. 253–260). Springer Berlin Heidelberg.
Abstract: Computational simulations of the heart are a powerful tool for a comprehensive understanding of cardiac function and its intrinsic relationship with its muscular architecture. Cardiac biomechanical models require a vector field representing the orientation of cardiac fibers. A wrong orientation of the fibers can lead to a
non-realistic simulation of the heart functionality. In this paper we explore the impact of the fiber information on the simulated biomechanics of cardiac muscular anatomy. We have used the John Hopkins database to perform a biomechanical simulation using both a synthetic benchmark fiber distribution and the data obtained experimentally from DTI. Results illustrate how differences in fiber orientation affect heart deformation along cardiac cycle.
|
|
|
Naveen Onkarappa, Sujay M. Veerabhadrappa, & Angel Sappa. (2012). Optical Flow in Onboard Applications: A Study on the Relationship Between Accuracy and Scene Texture. In 4th International Conference on Signal and Image Processing (Vol. 221, pp. 257–267).
Abstract: Optical flow has got a major role in making advanced driver assistance systems (ADAS) a reality. ADAS applications are expected to perform efficiently in all kinds of environments, those are highly probable, that one can drive the vehicle in different kinds of roads, times and seasons. In this work, we study the relationship of optical flow with different roads, that is by analyzing optical flow accuracy on different road textures. Texture measures such as TeX , TeX and TeX are evaluated for this purpose. Further, the relation of regularization weight to the flow accuracy in the presence of different textures is also analyzed. Additionally, we present a framework to generate synthetic sequences of different textures in ADAS scenarios with ground-truth optical flow.
|
|
|
Mohammad Rouhani, & Angel Sappa. (2012). Non-Rigid Shape Registration: A Single Linear Least Squares Framework. In 12th European Conference on Computer Vision (Vol. 7578, pp. 264–277). LNCS. Springer Berlin Heidelberg.
Abstract: This paper proposes a non-rigid registration formulation capturing both global and local deformations in a single framework. This formulation is based on a quadratic estimation of the registration distance together with a quadratic regularization term. Hence, the optimal transformation parameters are easily obtained by solving a liner system of equations, which guarantee a fast convergence. Experimental results with challenging 2D and 3D shapes are presented to show the validity of the proposed framework. Furthermore, comparisons with the most relevant approaches are provided.
|
|
|
Sergio Vera, Miguel Angel Gonzalez Ballester, & Debora Gil. (2012). Optimal Medial Surface Generation for Anatomical Volume Representations. In MichaelW. David and Vannier H. and H. Yoshida (Ed.), Abdominal Imaging. Computational and Clinical Applications (Vol. 7601, pp. 265–273). Lecture Notes in Computer Science. Springer Berlin Heidelberg.
Abstract: Medial representations are a widely used technique in abdominal organ shape representation and parametrization. Those methods require good medial manifolds as a starting point. Any medial
surface used to parametrize a volume should be simple enough to allow an easy manipulation and complete enough to allow an accurate reconstruction of the volume. Obtaining good quality medial
surfaces is still a problem with current iterative thinning methods. This forces the usage of generic, pre-calculated medial templates that are adapted to the final shape at the cost of a drop in volume reconstruction.
This paper describes an operator for generation of medial structures that generates clean and complete manifolds well suited for their further use in medial representations of abdominal organ volumes. While being simpler than thinning surfaces, experiments show its high performance in volume reconstruction and preservation of medial surface main branching topology.
Keywords: Medial surface representation; volume reconstruction
|
|
|
Ferran Poveda, Debora Gil, & Enric Marti. (2012). Multi-resolution DT-MRI cardiac tractography. In Statistical Atlases And Computational Models Of The Heart: Imaging and Modelling Challenges (Vol. 7746, pp. 270–277). LNCS. Springer Berlin Heidelberg.
Abstract: Even using objective measures from DT-MRI no consensus about myocardial architecture has been achieved so far. Streamlining provides good reconstructions at low level of detail, but falls short to give global abstract interpretations. In this paper, we present a multi-resolution methodology that is able to produce simplified representations of cardiac architecture. Our approach produces a reduced set of tracts that are representative of the main geometric features of myocardial anatomical structure. Experiments show that fiber geometry is preserved along reductions, which validates the simplified model for interpretation of cardiac architecture.
|
|
|
Francesc Carreras, Jaume Garcia, Debora Gil, Sandra Pujadas, Chi ho Lion, R.Suarez-Arias, et al. (2012). Left ventricular torsion and longitudinal shortening: two fundamental components of myocardial mechanics assessed by tagged cine-MRI in normal subjects. IJCI - International Journal of Cardiovascular Imaging, 28(2), 273–284.
Abstract: Cardiac magnetic resonance imaging (Cardiac MRI) has become a gold standard diagnostic technique for the assessment of cardiac mechanics, allowing the non-invasive calculation of left ventric- ular long axis longitudinal shortening (LVLS) and absolute myocardial torsion (AMT) between basal and apical left ventricular slices, a movement directly related to the helicoidal anatomic disposition of the myocardial fibers. The aim of this study is to determine AMT and LVLS behaviour and normal values from a group of healthy subjects. A group of 21 healthy volunteers (15 males) (age: 23–55 y.o., mean:30.7 ± 7.5) were prospectively included in an obser- vational study by Cardiac MRI. Left ventricular rotation (degrees) was calculated by custom-made software (Harmonic Phase Flow) in consecutive LV short axis planes tagged cine-MRI sequences. AMT was determined from the difference between basal and apical planes LV rotations. LVLS (%) was determined from the LV longitudinal and horizontal axis cine-MRI images. All the 21 cases studied were interpretable, although in three cases the value of the LV apical rotation could not be determined. The mean rotation of the basal and apical planes at end-systole were -3.71° ± 0.84° and 6.73° ± 1.69° (n:18) respectively, resulting in a LV mean AMT of 10.48° ± 1.63° (n:18). End-systolic mean LVLS was 19.07 ± 2.71%. Cardiac MRI allows for the calculation of AMT and LVLS, fundamental functional components of the ventricular twist mechanics conditioned, in turn, by the anatomical helical layout of the myocardial fibers. These values provide complementary information about systolic ventricular function in relation to the traditional parameters used in daily practice.
Keywords: Magnetic resonance imaging (MRI); Tagging MRI; Cardiac mechanics; Ventricular torsion
|
|
|
Marc Serra, Olivier Penacchio, Robert Benavente, & Maria Vanrell. (2012). Names and Shades of Color for Intrinsic Image Estimation. In 25th IEEE Conference on Computer Vision and Pattern Recognition (pp. 278–285). IEEE Xplore.
Abstract: In the last years, intrinsic image decomposition has gained attention. Most of the state-of-the-art methods are based on the assumption that reflectance changes come along with strong image edges. Recently, user intervention in the recovery problem has proved to be a remarkable source of improvement. In this paper, we propose a novel approach that aims to overcome the shortcomings of pure edge-based methods by introducing strong surface descriptors, such as the color-name descriptor which introduces high-level considerations resembling top-down intervention. We also use a second surface descriptor, termed color-shade, which allows us to include physical considerations derived from the image formation model capturing gradual color surface variations. Both color cues are combined by means of a Markov Random Field. The method is quantitatively tested on the MIT ground truth dataset using different error metrics, achieving state-of-the-art performance.
|
|
|
Sergio Escalera. (2012). Human Behavior Analysis From Depth Maps. In F.J. Perales, R.B. Fisher, & T.B. Moeslund (Eds.), 7th Conference on Articulated Motion and Deformable Objects (Vol. 7378, pp. 282–292). Springer Heidelberg.
Abstract: Pose Recovery (PR) and Human Behavior Analysis (HBA) have been a main focus of interest from the beginnings of Computer Vision and Machine Learning. PR and HBA were originally addressed by the analysis of still images and image sequences. More recent strategies consisted of Motion Capture technology (MOCAP), based on the synchronization of multiple cameras in controlled environments; and the analysis of depth maps from Time-of-Flight (ToF) technology, based on range image recording from distance sensor measurements. Recently, with the appearance of the multi-modal RGBD information provided by the low cost Kinect \textsfTM sensor (from RGB and Depth, respectively), classical methods for PR and HBA have been redefined, and new strategies have been proposed. In this paper, the recent contributions and future trends of multi-modal RGBD data analysis for PR and HBA are reviewed and discussed.
|
|
|
Joost Van de Weijer, Robert Benavente, Maria Vanrell, Cordelia Schmid, Ramon Baldrich, Jacob Verbeek, et al. (2012). Color Naming. In Theo Gevers, Arjan Gijsenij, Joost Van de Weijer, & Jan-Mark Geusebroek (Eds.), Color in Computer Vision: Fundamentals and Applications (pp. 287–317). John Wiley & Sons, Ltd.
|
|
|
Miguel Oliveira, Angel Sappa, & V. Santos. (2012). Color Correction for Onboard Multi-camera Systems using 3D Gaussian Mixture Models. In IEEE Intelligent Vehicles Symposium (pp. 299–303). IEEE Xplore.
Abstract: The current paper proposes a novel color correction approach for onboard multi-camera systems. It works by segmenting the given images into several regions. A probabilistic segmentation framework, using 3D Gaussian Mixture Models, is proposed. Regions are used to compute local color correction functions, which are then combined to obtain the final corrected image. An image data set of road scenarios is used to establish a performance comparison of the proposed method with other seven well known color correction algorithms. Results show that the proposed approach is the highest scoring color correction method. Also, the proposed single step 3D color space probabilistic segmentation reduces processing time over similar approaches.
|
|
|
Emanuel Indermühle, Volkmar Frinken, & Horst Bunke. (2012). Mode Detection in Online Handwritten Documents using BLSTM Neural Networks. In 13th International Conference on Frontiers in Handwriting Recognition (pp. 302–307).
Abstract: Mode detection in online handwritten documents refers to the process of distinguishing different types of contents, such as text, formulas, diagrams, or tables, one from another. In this paper a new approach to mode detection is proposed that uses bidirectional long-short term memory (BLSTM) neural networks. The BLSTM neural network is a novel type of recursive neural network that has been successfully applied in speech and handwriting recognition. In this paper we show that it has the potential to significantly outperform traditional methods for mode detection, which are usually based on stroke classification. As a further advantage over previous approaches, the proposed system is trainable and does not rely on user-defined heuristics. Moreover, it can be easily adapted to new or additional types of modes by just providing the system with new training data.
|
|
|
Jordi Gonzalez, Thomas B. Moeslund, & Liang Wang. (2012). Semantic Understanding of Human Behaviors in Image Sequences: From video-surveillance to video-hermeneutics. CVIU - Computer Vision and Image Understanding, 116(3), 305–306.
Abstract: Purpose: Atheromatic plaque progression is affected, among others phenomena, by biomechanical, biochemical, and physiological factors. In this paper, the authors introduce a novel framework able to provide both morphological (vessel radius, plaque thickness, and type) and biomechanical (wall shear stress and Von Mises stress) indices of coronary arteries.Methods: First, the approach reconstructs the three-dimensional morphology of the vessel from intravascular ultrasound (IVUS) and Angiographic sequences, requiring minimal user interaction. Then, a computational pipeline allows to automatically assess fluid-dynamic and mechanical indices. Ten coronary arteries are analyzed illustrating the capabilities of the tool and confirming previous technical and clinical observations.Results: The relations between the arterial indices obtained by IVUS measurement and simulations have been quantitatively analyzed along the whole surface of the artery, extending the analysis of the coronary arteries shown in previous state of the art studies. Additionally, for the first time in the literature, the framework allows the computation of the membrane stresses using a simplified mechanical model of the arterial wall.Conclusions: Circumferentially (within a given frame), statistical analysis shows an inverse relation between the wall shear stress and the plaque thickness. At the global level (comparing a frame within the entire vessel), it is observed that heavy plaque accumulations are in general calcified and are located in the areas of the vessel having high wall shear stress. Finally, in their experiments the inverse proportionality between fluid and structural stresses is observed.
|
|
|
Carles Sanchez, F. Javier Sanchez, Antoni Rosell, & Debora Gil. (2012). An illumination model of the trachea appearance in videobronchoscopy images. In Image Analysis and Recognition (Vol. 7325, pp. 313–320). LNCS. Springer Berlin Heidelberg.
Abstract: Videobronchoscopy is a medical imaging technique that allows interactive navigation inside the respiratory pathways. This imaging modality provides realistic images and allows non-invasive minimal intervention procedures. Tracheal procedures are routinary interventions that require assessment of the percentage of obstructed pathway for injury (stenosis) detection. Visual assessment in videobronchoscopic sequences requires high expertise of trachea anatomy and is prone to human error.
This paper introduces an automatic method for the estimation of steneosed trachea percentage reduction in videobronchoscopic images. We look for tracheal rings , whose deformation determines the degree of obstruction. For ring extraction , we present a ring detector based on an illumination and appearance model. This model allows us to parametrise the ring detection. Finally, we can infer optimal estimation parameters for any video resolution.
Keywords: Bronchoscopy, tracheal ring, stenosis assesment, trachea appearance model, segmentation
|
|