|
Records |
Links |
|
Author |
David Roche; Debora Gil; Jesus Giraldo |
|
|
Title |
Mathematical modeling of G protein-coupled receptor function: What can we learn from empirical and mechanistic models? |
Type |
Book Chapter |
|
Year |
2014 |
Publication |
G Protein-Coupled Receptors – Modeling and Simulation Advances in Experimental Medicine and Biology |
Abbreviated Journal |
|
|
|
Volume |
796 |
Issue |
3 |
Pages |
159-181 |
|
|
Keywords |
β-arrestin; biased agonism; curve fitting; empirical modeling; evolutionary algorithm; functional selectivity; G protein; GPCR; Hill coefficient; intrinsic efficacy; inverse agonism; mathematical modeling; mechanistic modeling; operational model; parameter optimization; receptor dimer; receptor oligomerization; receptor constitutive activity; signal transduction; two-state model |
|
|
Abstract |
Empirical and mechanistic models differ in their approaches to the analysis of pharmacological effect. Whereas the parameters of the former are not physical constants those of the latter embody the nature, often complex, of biology. Empirical models are exclusively used for curve fitting, merely to characterize the shape of the E/[A] curves. Mechanistic models, on the contrary, enable the examination of mechanistic hypotheses by parameter simulation. Regretfully, the many parameters that mechanistic models may include can represent a great difficulty for curve fitting, representing, thus, a challenge for computational method development. In the present study some empirical and mechanistic models are shown and the connections, which may appear in a number of cases between them, are analyzed from the curves they yield. It may be concluded that systematic and careful curve shape analysis can be extremely useful for the understanding of receptor function, ligand classification and drug discovery, thus providing a common language for the communication between pharmacologists and medicinal chemists. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Netherlands |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0065-2598 |
ISBN |
978-94-007-7422-3 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; 600.075 |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RGG2014 |
Serial |
2197 |
|
Permanent link to this record |
|
|
|
|
Author |
Petia Radeva; Amir Amini; Jintao Huang; Enric Marti |
|
|
Title |
Deformable B-Solids: application for localization and tracking of MRI-SPAMM data |
Type |
Report |
|
Year |
1996 |
Publication |
CVC Technical Report |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
8 |
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
To date, MRI-SPAMM data from different image slices have been analyzed independently. In this paper, we propose an approach for 3D tag localization and tracking of SPAMM data by a novel deformable B-solid. The solid is defined in terms of a 3D tensor product B-spline. The isoparametric curves of the B-spline solid have special importance. These are termed implicit snakes as they deform under image forces from tag lines in different image slices. The localization and tracking of tag lines is performed under constraints of continuity and smoothness of the B-solid. The framework unifies the problems of localization, and displacement fitting and interpolation into the same procedure utilizing B-spline bases for interpolation. To track motion from boundaries and restrict image forces to the myocardium, a volumetric model is employed as a pair of coupled endocardial and epicardial B-spline surfaces. To recover deformations in the LV an energy-minimization problem is posed where both tag and ... |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
CVC (UAB) |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB;IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RHM1996 |
Serial |
1631 |
|
Permanent link to this record |
|
|
|
|
Author |
Oriol Rodriguez-Leor; J. Mauri; Eduard Fernandez-Nofrerias; M. Gomez; Antonio Tovar; L. Cano; C. Diego; Carme Julia; Vicente del Valle; Debora Gil; Petia Radeva |
|
|
Title |
Ecografia Intracoronària: Segmentació Automàtica de area de la llum |
Type |
Conference Article |
|
Year |
2002 |
Publication |
XXXVIII Congreso Nacional de la Sociedad Española de Cardiología. |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;ADAS;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RMF2002 |
Serial |
1638 |
|
Permanent link to this record |
|
|
|
|
Author |
Oriol Rodriguez-Leor; J. Mauri; Eduard Fernandez-Nofrerias; C. Garcia; R. Villuendas; Vicente del Valle; Debora Gil; Petia Radeva |
|
|
Title |
Reconstruction of a spatio-temporal model of the intima layer from intravascular ultrasound sequences |
Type |
Journal Article |
|
Year |
2003 |
Publication |
European Heart Journal |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ESC Congress |
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RMF2003c |
Serial |
1641 |
|
Permanent link to this record |
|
|
|
|
Author |
Oriol Rodriguez-Leor; J. Mauri; Eduard Fernandez-Nofrerias; Antonio Tovar; Vicente del Valle; Aura Hernandez-Sabate; Debora Gil; Petia Radeva |
|
|
Title |
Utilización de la Estructura de los Campos Vectoriales para la Detección de la Adventicia en Imágenes de Ecografía Intracoronaria |
Type |
Journal Article |
|
Year |
2004 |
Publication |
Revista Internacional de Enfermedades Cardiovasculares Revista Española de Cardiología |
Abbreviated Journal |
|
|
|
Volume |
57 |
Issue |
2 |
Pages |
100 |
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
SEC |
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RMF2004 |
Serial |
1642 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Aura Hernandez-Sabate; Antoni Carol; Oriol Rodriguez; Petia Radeva |
|
|
Title |
A Deterministic-Statistic Adventitia Detection in IVUS Images |
Type |
Conference Article |
|
Year |
2005 |
Publication |
3rd International workshop on International Workshop on Functional Imaging and Modeling of the Heart |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
65-74 |
|
|
Keywords |
Electron microscopy; Unbending; 2D crystal; Interpolation; Approximation |
|
|
Abstract |
Plaque analysis in IVUS planes needs accurate intima and adventitia models. Large variety in adventitia descriptors difficulties its detection and motivates using a classification strategy for selecting points on the structure. Whatever the set of descriptors used, the selection stage suffers from fake responses due to noise and uncompleted true curves. In order to smooth background noise while strengthening responses, we apply a restricted anisotropic filter that homogenizes grey levels along the image significant structures. Candidate points are extracted by means of a simple semi supervised adaptive classification of the filtered image response to edge and calcium detectors. The final model is obtained by interpolating the former line segments with an anisotropic contour closing technique based on functional extension principles. |
|
|
Address |
Barcelona; June 2005 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
FIMH |
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RMF2005 |
Serial |
1524 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Aura Hernandez-Sabate; Antoni Carol; Oriol Rodriguez; Petia Radeva |
|
|
Title |
A Deterministic-Statistic Adventitia Detection in IVUS Images |
Type |
Conference Article |
|
Year |
2005 |
Publication |
ESC Congress |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
Electron microscopy; Unbending; 2D crystal; Interpolation; Approximation |
|
|
Abstract |
Plaque analysis in IVUS planes needs accurate intima and adventitia models. Large variety in adventitia descriptors difficulties its detection and motivates using a classification strategy for selecting points on the structure. Whatever the set of descriptors used, the selection stage suffers from fake responses due to noise and uncompleted true curves. In order to smooth background noise while strengthening responses, we apply a restricted anisotropic filter that homogenizes grey levels along the image significant structures. Candidate points are extracted by means of a simple semi supervised adaptive classification of the filtered image response to edge and calcium detectors. The final model is obtained by interpolating the former line segments with an anisotropic contour closing technique based on functional extension principles. |
|
|
Address |
Stockholm; Sweden; September 2005 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
,Sweden (EU) |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ESC |
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RMF2005a |
Serial |
1523 |
|
Permanent link to this record |
|
|
|
|
Author |
Oriol Rodriguez-Leor; J. Mauri; Eduard Fernandez-Nofrerias; Vicente de Valle; E. Garcia; A. Barrios; Debora Gil; Petia Radeva |
|
|
Title |
Analysis of the changes in angiography local grey-level values to determine myocardial perfusion |
Type |
Conference Article |
|
Year |
2006 |
Publication |
World Congress of Cardiology |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
862 |
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Barcelona (Spain) |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RMF2006 |
Serial |
1644 |
|
Permanent link to this record |
|
|
|
|
Author |
David Rotger; Misael Rosales; Jaume Garcia; Oriol Pujol ; J. Mauri; Petia Radeva |
|
|
Title |
Active Vessel: A New Multimedia Workstation for Intravascular Ultrasound and Angiography Fusion |
Type |
Journal Article |
|
Year |
2003 |
Publication |
Computers in Cardiology |
Abbreviated Journal |
|
|
|
Volume |
30 |
Issue |
|
Pages |
65-68 |
|
|
Keywords |
|
|
|
Abstract |
AcriveVessel is a new multimedia workstation which enables the visualization, acquisition and handling of both image modalities, on- and ofline. It enables DICOM v3.0 decompression and browsing, video acquisition,repmduction and storage for IntraVascular UltraSound (IVUS) and angiograms with their corresponding ECG,automatic catheter segmentation in angiography images (using fast marching algorithm). BSpline models definition for vessel layers on IVUS images sequence and an extensively validated tool to fuse information. This approach defines the correspondence of every IVUS image with its correspondent point in the angiogram and viceversa. The 3 0 reconstruction of the NUS catheterhessel enables real distance measurements as well as threedimensional visualization showing vessel tortuosity in the space. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB;HuPBA |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RRG2003 |
Serial |
1647 |
|
Permanent link to this record |
|
|
|
|
Author |
Misael Rosales; Petia Radeva; Oriol Rodriguez; Debora Gil |
|
|
Title |
Suppression of IVUS Image Rotation. A Kinematic Approach |
Type |
Book Chapter |
|
Year |
2005 |
Publication |
Functional Imaging and Modeling of the Heart |
Abbreviated Journal |
LNCS |
|
|
Volume |
3504 |
Issue |
|
Pages |
889-892 |
|
|
Keywords |
|
|
|
Abstract |
IntraVascular Ultrasound (IVUS) is an exploratory technique used in interventional procedures that shows cross section images of arteries and provides qualitative information about the causes and severity of the arterial lumen narrowing. Cross section analysis as well as visualization of plaque extension in a vessel segment during the catheter imaging pullback are the technique main advantages. However, IVUS sequence exhibits a periodic rotation artifact that makes difficult the longitudinal lesion inspection and hinders any segmentation algorithm. In this paper we propose a new kinematic method to estimate and remove the image rotation of IVUS images sequences. Results on several IVUS sequences show good results and prompt some of the clinical applications to vessel dynamics study, and relation to vessel pathology. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Berlin / Heidelberg |
Place of Publication |
|
Editor |
Frangi, Alejandro and Radeva, Petia and Santos, Andres and Hernandez, Monica |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
Lecture Notes in Computer Science |
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
3504 |
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RRR2005 |
Serial |
1645 |
|
Permanent link to this record |
|
|
|
|
Author |
Misael Rosales; Petia Radeva; Oriol Rodriguez-Leor; Debora Gil |
|
|
Title |
Modelling of image-catheter motion for 3-D IVUS |
Type |
Journal Article |
|
Year |
2009 |
Publication |
Medical image analysis |
Abbreviated Journal |
MIA |
|
|
Volume |
13 |
Issue |
1 |
Pages |
91-104 |
|
|
Keywords |
Intravascular ultrasound (IVUS); Motion estimation; Motion decomposition; Fourier |
|
|
Abstract |
Three-dimensional intravascular ultrasound (IVUS) allows to visualize and obtain volumetric measurements of coronary lesions through an exploration of the cross sections and longitudinal views of arteries. However, the visualization and subsequent morpho-geometric measurements in IVUS longitudinal cuts are subject to distortion caused by periodic image/vessel motion around the IVUS catheter. Usually, to overcome the image motion artifact ECG-gating and image-gated approaches are proposed, leading to slowing the pullback acquisition or disregarding part of IVUS data. In this paper, we argue that the image motion is due to 3-D vessel geometry as well as cardiac dynamics, and propose a dynamic model based on the tracking of an elliptical vessel approximation to recover the rigid transformation and align IVUS images without loosing any IVUS data. We report an extensive validation with synthetic simulated data and in vivo IVUS sequences of 30 patients achieving an average reduction of the image artifact of 97% in synthetic data and 79% in real-data. Our study shows that IVUS alignment improves longitudinal analysis of the IVUS data and is a necessary step towards accurate reconstruction and volumetric measurements of 3-D IVUS. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RRR2009 |
Serial |
1646 |
|
Permanent link to this record |
|
|
|
|
Author |
Petia Radeva; Joan Serrat; Enric Marti |
|
|
Title |
A snake for model-based segmentation |
Type |
Conference Article |
|
Year |
1995 |
Publication |
Proc. Conf. Fifth Int Computer Vision |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
816-821 |
|
|
Keywords |
snakes; elastic matching; model-based segmenta tion |
|
|
Abstract |
Despite the promising results of numerous applications, the hitherto proposed snake techniques share some common problems: snake attraction by spurious edge points, snake degeneration (shrinking and attening), convergence and stability of the deformation process, snake initialization and local determination of the parameters of elasticity. We argue here that these problems can be solved only when all the snake aspects are considered. The snakes proposed here implement a new potential eld and external force in order to provide a deformation convergence, attraction by both near and far edges as well as snake behaviour selective according to the edge orientation. Furthermore, we conclude that in the case of model-based seg mentation, the internal force should include structural information about the expected snake shape. Experiments using this kind of snakes for segmenting bones in complex hand radiographs show a signicant improvement. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB;ADAS;IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RSM1995 |
Serial |
1634 |
|
Permanent link to this record |
|
|
|
|
Author |
Petia Radeva; Jordi Vitria; Fernando Vilariño; Panagiota Spyridonos; Fernando Azpiroz; Juan Malagelada; Fosca de Iorio; Anna Accarino |
|
|
Title |
Cascade analysis for intestinal contraction detection |
Type |
Patent |
|
Year |
2009 |
Publication |
US 2009/0284589 A1 |
Abbreviated Journal |
USPO |
|
|
Volume |
|
Issue |
|
Pages |
1-25 |
|
|
Keywords |
|
|
|
Abstract |
A method and system cascade analysisi for intestinal contraction detection is provided by extracting from image frames captured in-vivo. The method and system also relate to the detection of turbid liquids in intestinal tracts, to automatic detection of video image frames taken in the gastrointestinal tract including a field of view obstructed by turbid media, and more particulary, to extraction of image data obstructed by turbid media. |
|
|
Address |
|
|
|
Corporate Author |
US Patent Office |
Thesis |
|
|
|
Publisher |
US Patent Office |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB; OR; MV;SIAI |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RVV2009 |
Serial |
1700 |
|
Permanent link to this record |
|
|
|
|
Author |
Carles Sanchez |
|
|
Title |
Tracheal ring detection in bronchoscopy |
Type |
Report |
|
Year |
2011 |
Publication |
CVC Technical Report |
Abbreviated Journal |
|
|
|
Volume |
168 |
Issue |
|
Pages |
|
|
|
Keywords |
Bronchoscopy, tracheal ring, segmentation |
|
|
Abstract |
Endoscopy is the process in which a camera is introduced inside a human.
Given that endoscopy provides realistic images (in contrast to other modalities) and allows non-invase minimal intervention procedures (which can aid in diagnosis and surgical interventions), its use has spreaded during last decades.
In this project we will focus on bronchoscopic procedures, during which the camera is introduced through the trachea in order to have a diagnostic of the patient. The diagnostic interventions are focused on: degree of stenosis (reduction in tracheal area), prosthesis or early diagnosis of tumors. In the first case, assessment of the luminal area and the calculation of the diameters of the tracheal rings are required. A main limitation is that all the process is done by hand,
which means that the doctor takes all the measurements and decisions just by looking at the screen. As far as we know there is no computational framework for helping the doctors in the diagnosis.
This project will consist of analysing bronchoscopic videos in order to extract useful information for the diagnostic of the degree of stenosis. In particular we will focus on segmentation of the tracheal rings. As a result of this project several strategies (for detecting tracheal rings) had been implemented in order to compare their performance. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
Master's thesis |
|
|
Publisher |
|
Place of Publication |
|
Editor |
Debora Gil, F.Javier Sanchez |
|
|
Language |
english |
Summary Language |
english |
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MV |
Approved |
no |
|
|
Call Number |
IAM @ iam @ San2011 |
Serial |
1841 |
|
Permanent link to this record |
|
|
|
|
Author |
C. Santa-Marta; Jaume Garcia; A. Bajo; J.J. Vaquero; M. Ledesma-Carbayo; Debora Gil |
|
|
Title |
Influence of the Temporal Resolution on the Quantification of Displacement Fields in Cardiac Magnetic Resonance Tagged Images |
Type |
Conference Article |
|
Year |
2008 |
Publication |
XXVI Congreso Anual de la Sociedad Española de Ingenieria Biomedica |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
352–353 |
|
|
Keywords |
|
|
|
Abstract |
It is difficult to acquire tagged cardiac MR images with a high temporal and spatial resolution using clinical MR scanners. However, if such images are used for quantifying scores based on motion, it is essential a resolution as high as possibl e. This paper explores the influence of the temporal resolution of a tagged series on the quantification of myocardial dynamic parameters. To such purpose we have designed a SPAMM (Spatial Modulation of Magnetization) sequence allowing acquisition of sequences at simple and double temporal resolution. Sequences are processed to compute myocardial motion by an automatic technique based on the tracking of the harmonic phase of tagged images (the Harmonic Phase Flow, HPF). The results have been compared to manual tracking of myocardial tags. The error in displacement fields for double resolution sequences reduces 17%. |
|
|
Address |
Valladolid |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
Roberto hornero, Saniel Abasolo |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
CASEIB |
|
|
Notes |
IAM; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ SGB2008 |
Serial |
1033 |
|
Permanent link to this record |