toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
  Records Links
Author Debora Gil; Petia Radeva edit   pdf
doi  openurl
  Title A Regularized Curvature Flow Designed for a Selective Shape Restoration Type Journal Article
  Year 2004 Publication IEEE Transactions on Image Processing Abbreviated Journal  
  Volume 13 Issue Pages 1444–1458  
  Keywords Geometric flows, nonlinear filtering, shape recovery.  
  Abstract Among all filtering techniques, those based exclu- sively on image level sets (geometric flows) have proven to be the less sensitive to the nature of noise and the most contrast preserving. A common feature to existent curvature flows is that they penalize high curvature, regardless of the curve regularity. This constitutes a major drawback since curvature extreme values are standard descriptors of the contour geometry. We argue that an operator designed with shape recovery purposes should include a term penalizing irregularity in the curvature rather than its magnitude. To this purpose, we present a novel geometric flow that includes a function that measures the degree of local irregularity present in the curve. A main advantage is that it achieves non-trivial steady states representing a smooth model of level curves in a noisy image. Performance of our approach is compared to classical filtering techniques in terms of quality in the restored image/shape and asymptotic behavior. We empirically prove that our approach is the technique that achieves the best compromise between image quality and evolution stabilization.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference (up)  
  Notes IAM;MILAB Approved no  
  Call Number BCNPCL @ bcnpcl @ GiR2004b Serial 491  
Permanent link to this record
 

 
Author Jaume Garcia; Debora Gil; Sandra Pujades; Francesc Carreras edit   pdf
openurl 
  Title Valoracion de la Funcion del Ventriculo Izquierdo mediante Modelos Regionales Hiperparametricos Type Journal Article
  Year 2008 Publication Revista Española de Cardiologia Abbreviated Journal  
  Volume 61 Issue 3 Pages 79  
  Keywords  
  Abstract La mayoría de la enfermedades cardiovasculares afectan a las propiedades contráctiles de la banda ventricular helicoidal. Esto se refleja en una variación del comportamiento normal de la función ventricular. Parámetros locales tales como los strains, o la deformación experimentada por el tejido, son indicadores capaces de detectar anomalías funcionales en territorios específicos. A menudo, dichos parámetros son considerados de forma separada. En este trabajo presentamos un marco computacional (el Dominio Paramétrico Normalizado, DPN) que permite integrarlos en hiperparámetros funcionales y estudiar sus rangos de normalidad. Dichos rangos permiten valorar de forma objetiva la función regional de cualquier nuevo paciente. Para ello, consideramos secuencias de resonancia magnética etiquetada a nivel basal, medio y apical. Los hiperparámetros se obtienen a partir del movimiento intramural del VI estimado mediante el método Harmonic Phase Flow. El DPN se define a partir de en una parametrización del Ventrículo Izquierdo (VI) en sus coordenadas radiales y circunferencial basada en criterios anatómicos. El paso de los hiperparámetros al DPN hace posible la comparación entre distintos pacientes. Los rangos de normalidad se definen mediante análisis estadístico de valores de voluntarios sanos en 45 regiones del DPN a lo largo de 9 fases sistólicas. Se ha usado un conjunto de 19 (14 H; E: 30.7±7.5) voluntarios sanos para crear los patrones de normalidad y se han validado usando 2 controles sanos y 3 pacientes afectados de contractilidad global reducida. Para los controles los resultados regionales se han ajustado dentro de la normalidad, mientras que para los pacientes se han obtenido valores anormales en las zonas descritas, localizando y cuantificando así el diagnóstico empírico.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference (up)  
  Notes IAM; Approved no  
  Call Number IAM @ iam @ GRP2008 Serial 1032  
Permanent link to this record
 

 
Author Jaume Garcia; Debora Gil; Sandra Pujades; Francesc Carreras edit   pdf
doi  openurl
  Title A Variational Framework for Assessment of the Left Ventricle Motion Type Journal Article
  Year 2008 Publication International Journal Mathematical Modelling of Natural Phenomena Abbreviated Journal  
  Volume 3 Issue 6 Pages 76-100  
  Keywords Key words: Left Ventricle Dynamics, Ventricular Torsion, Tagged Magnetic Resonance, Motion Tracking, Variational Framework, Gabor Transform.  
  Abstract Impairment of left ventricular contractility due to cardiovascular diseases is reflected in left ventricle (LV) motion patterns. An abnormal change of torsion or long axis shortening LV values can help with the diagnosis and follow-up of LV dysfunction. Tagged Magnetic Resonance (TMR) is a widely spread medical imaging modality that allows estimation of the myocardial tissue local deformation. In this work, we introduce a novel variational framework for extracting the left ventricle dynamics from TMR sequences. A bi-dimensional representation space of TMR images given by Gabor filter banks is defined. Tracking of the phases of the Gabor response is combined using a variational framework which regularizes the deformation field just at areas where the Gabor amplitude drops, while restoring the underlying motion otherwise. The clinical applicability of the proposed method is illustrated by extracting normality models of the ventricular torsion from 19 healthy subjects.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference (up)  
  Notes IAM Approved no  
  Call Number IAM @ iam @ GGC2008a Serial 1058  
Permanent link to this record
 

 
Author Mariano Vazquez; Ruth Aris; Guillaume Hozeaux; R.Aubry; P.Villar;Jaume Garcia ; Debora Gil; Francesc Carreras edit   pdf
url  doi
openurl 
  Title A massively parallel computational electrophysiology model of the heart Type Journal Article
  Year 2011 Publication International Journal for Numerical Methods in Biomedical Engineering Abbreviated Journal IJNMBE  
  Volume 27 Issue Pages 1911-1929  
  Keywords computational electrophysiology; parallelization; finite element methods  
  Abstract This paper presents a patient-sensitive simulation strategy capable of using the most efficient way the high-performance computational resources. The proposed strategy directly involves three different players: Computational Mechanics Scientists (CMS), Image Processing Scientists and Cardiologists, each one mastering its own expertise area within the project. This paper describes the general integrative scheme but focusing on the CMS side presents a massively parallel implementation of computational electrophysiology applied to cardiac tissue simulation. The paper covers different angles of the computational problem: equations, numerical issues, the algorithm and parallel implementation. The proposed methodology is illustrated with numerical simulations testing all the different possibilities, ranging from small domains up to very large ones. A key issue is the almost ideal scalability not only for large and complex problems but also for medium-size meshes. The explicit formulation is particularly well suited for solving this highly transient problems, with very short time-scale.  
  Address Swansea (UK)  
  Corporate Author John Wiley & Sons, Ltd. Thesis  
  Publisher John Wiley & Sons, Ltd. Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference (up)  
  Notes IAM Approved no  
  Call Number IAM @ iam @ VAH2011 Serial 1198  
Permanent link to this record
 

 
Author Francesc Carreras; Jaume Garcia; Debora Gil; Sandra Pujadas; Chi ho Lion; R.Suarez-Arias; R.Leta; Xavier Alomar; Manuel Ballester; Guillem Pons-Llados edit  url
doi  openurl
  Title Left ventricular torsion and longitudinal shortening: two fundamental components of myocardial mechanics assessed by tagged cine-MRI in normal subjects Type Journal Article
  Year 2012 Publication International Journal of Cardiovascular Imaging Abbreviated Journal IJCI  
  Volume 28 Issue 2 Pages 273-284  
  Keywords Magnetic resonance imaging (MRI); Tagging MRI; Cardiac mechanics; Ventricular torsion  
  Abstract Cardiac magnetic resonance imaging (Cardiac MRI) has become a gold standard diagnostic technique for the assessment of cardiac mechanics, allowing the non-invasive calculation of left ventric- ular long axis longitudinal shortening (LVLS) and absolute myocardial torsion (AMT) between basal and apical left ventricular slices, a movement directly related to the helicoidal anatomic disposition of the myocardial fibers. The aim of this study is to determine AMT and LVLS behaviour and normal values from a group of healthy subjects. A group of 21 healthy volunteers (15 males) (age: 23–55 y.o., mean:30.7 ± 7.5) were prospectively included in an obser- vational study by Cardiac MRI. Left ventricular rotation (degrees) was calculated by custom-made software (Harmonic Phase Flow) in consecutive LV short axis planes tagged cine-MRI sequences. AMT was determined from the difference between basal and apical planes LV rotations. LVLS (%) was determined from the LV longitudinal and horizontal axis cine-MRI images. All the 21 cases studied were interpretable, although in three cases the value of the LV apical rotation could not be determined. The mean rotation of the basal and apical planes at end-systole were -3.71° ± 0.84° and 6.73° ± 1.69° (n:18) respectively, resulting in a LV mean AMT of 10.48° ± 1.63° (n:18). End-systolic mean LVLS was 19.07 ± 2.71%. Cardiac MRI allows for the calculation of AMT and LVLS, fundamental functional components of the ventricular twist mechanics conditioned, in turn, by the anatomical helical layout of the myocardial fibers. These values provide complementary information about systolic ventricular function in relation to the traditional parameters used in daily practice.  
  Address  
  Corporate Author Thesis  
  Publisher Springer Netherlands Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1569-5794 ISBN Medium  
  Area Expedition Conference (up)  
  Notes IAM; Approved no  
  Call Number IAM @ iam @ CGG2012 Serial 1496  
Permanent link to this record
Select All    Deselect All
 |   | 
Details

Save Citations:
Export Records: