|
Records |
Links |
|
Author |
Marta Ligero; Alonso Garcia Ruiz; Cristina Viaplana; Guillermo Villacampa; Maria V Raciti; Jaid Landa; Ignacio Matos; Juan Martin Liberal; Maria Ochoa de Olza; Cinta Hierro; Joaquin Mateo; Macarena Gonzalez; Rafael Morales Barrera; Cristina Suarez; Jordi Rodon; Elena Elez; Irene Braña; Eva Muñoz-Couselo; Ana Oaknin; Roberta Fasani; Paolo Nuciforo; Debora Gil; Carlota Rubio Perez; Joan Seoane; Enriqueta Felip; Manuel Escobar; Josep Tabernero; Joan Carles; Rodrigo Dienstmann; Elena Garralda; Raquel Perez Lopez |
|
|
Title |
A CT-based radiomics signature is associated with response to immune checkpoint inhibitors in advanced solid tumors |
Type |
Journal Article |
|
Year |
2021 |
Publication |
Radiology |
Abbreviated Journal |
|
|
|
Volume |
299 |
Issue |
1 |
Pages |
109-119 |
|
|
Keywords |
|
|
|
Abstract |
Background Reliable predictive imaging markers of response to immune checkpoint inhibitors are needed. Purpose To develop and validate a pretreatment CT-based radiomics signature to predict response to immune checkpoint inhibitors in advanced solid tumors. Materials and Methods In this retrospective study, a radiomics signature was developed in patients with advanced solid tumors (including breast, cervix, gastrointestinal) treated with anti-programmed cell death-1 or programmed cell death ligand-1 monotherapy from August 2012 to May 2018 (cohort 1). This was tested in patients with bladder and lung cancer (cohorts 2 and 3). Radiomics variables were extracted from all metastases delineated at pretreatment CT and selected by using an elastic-net model. A regression model combined radiomics and clinical variables with response as the end point. Biologic validation of the radiomics score with RNA profiling of cytotoxic cells (cohort 4) was assessed with Mann-Whitney analysis. Results The radiomics signature was developed in 85 patients (cohort 1: mean age, 58 years ± 13 [standard deviation]; 43 men) and tested on 46 patients (cohort 2: mean age, 70 years ± 12; 37 men) and 47 patients (cohort 3: mean age, 64 years ± 11; 40 men). Biologic validation was performed in a further cohort of 20 patients (cohort 4: mean age, 60 years ± 13; 14 men). The radiomics signature was associated with clinical response to immune checkpoint inhibitors (area under the curve [AUC], 0.70; 95% CI: 0.64, 0.77; P < .001). In cohorts 2 and 3, the AUC was 0.67 (95% CI: 0.58, 0.76) and 0.67 (95% CI: 0.56, 0.77; P < .001), respectively. A radiomics-clinical signature (including baseline albumin level and lymphocyte count) improved on radiomics-only performance (AUC, 0.74 [95% CI: 0.63, 0.84; P < .001]; Akaike information criterion, 107.00 and 109.90, respectively). Conclusion A pretreatment CT-based radiomics signature is associated with response to immune checkpoint inhibitors, likely reflecting the tumor immunophenotype. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Summers in this issue. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; 600.145 |
Approved |
no |
|
|
Call Number |
Admin @ si @ LGV2021 |
Serial |
3593 |
|
Permanent link to this record |
|
|
|
|
Author |
Juan Borrego-Carazo; Carles Sanchez; David Castells; Jordi Carrabina; Debora Gil |
|
|
Title |
A benchmark for the evaluation of computational methods for bronchoscopic navigation |
Type |
Journal Article |
|
Year |
2022 |
Publication |
International Journal of Computer Assisted Radiology and Surgery |
Abbreviated Journal |
IJCARS |
|
|
Volume |
17 |
Issue |
1 |
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
Admin @ si @ BSC2022 |
Serial |
3832 |
|
Permanent link to this record |
|
|
|
|
Author |
Sonia Baeza; Debora Gil; I.Garcia Olive; M.Salcedo; J.Deportos; Carles Sanchez; Guillermo Torres; G.Moragas; Antoni Rosell |
|
|
Title |
A novel intelligent radiomic analysis of perfusion SPECT/CT images to optimize pulmonary embolism diagnosis in COVID-19 patients |
Type |
Journal Article |
|
Year |
2022 |
Publication |
EJNMMI Physics |
Abbreviated Journal |
EJNMMI-PHYS |
|
|
Volume |
9 |
Issue |
1, Article 84 |
Pages |
1-17 |
|
|
Keywords |
|
|
|
Abstract |
Background: COVID-19 infection, especially in cases with pneumonia, is associated with a high rate of pulmonary embolism (PE). In patients with contraindications for CT pulmonary angiography (CTPA) or non-diagnostic CTPA, perfusion single-photon emission computed tomography/computed tomography (Q-SPECT/CT) is a diagnostic alternative. The goal of this study is to develop a radiomic diagnostic system to detect PE based only on the analysis of Q-SPECT/CT scans.
Methods: This radiomic diagnostic system is based on a local analysis of Q-SPECT/CT volumes that includes both CT and Q-SPECT values for each volume point. We present a combined approach that uses radiomic features extracted from each scan as input into a fully connected classifcation neural network that optimizes a weighted crossentropy loss trained to discriminate between three diferent types of image patterns (pixel sample level): healthy lungs (control group), PE and pneumonia. Four types of models using diferent confguration of parameters were tested.
Results: The proposed radiomic diagnostic system was trained on 20 patients (4,927 sets of samples of three types of image patterns) and validated in a group of 39 patients (4,410 sets of samples of three types of image patterns). In the training group, COVID-19 infection corresponded to 45% of the cases and 51.28% in the test group. In the test group, the best model for determining diferent types of image patterns with PE presented a sensitivity, specifcity, positive predictive value and negative predictive value of 75.1%, 98.2%, 88.9% and 95.4%, respectively. The best model for detecting
pneumonia presented a sensitivity, specifcity, positive predictive value and negative predictive value of 94.1%, 93.6%, 85.2% and 97.6%, respectively. The area under the curve (AUC) was 0.92 for PE and 0.91 for pneumonia. When the results obtained at the pixel sample level are aggregated into regions of interest, the sensitivity of the PE increases to 85%, and all metrics improve for pneumonia.
Conclusion: This radiomic diagnostic system was able to identify the diferent lung imaging patterns and is a frst step toward a comprehensive intelligent radiomic system to optimize the diagnosis of PE by Q-SPECT/CT. |
|
|
Address |
5 dec 2022 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
Admin @ si @ BGG2022 |
Serial |
3759 |
|
Permanent link to this record |
|
|
|
|
Author |
Ferran Poveda; Debora Gil; Enric Marti; Albert Andaluz; Manel Ballester;Francesc Carreras Costa |
|
|
Title |
Helical structure of the cardiac ventricular anatomy assessed by Diffusion Tensor Magnetic Resonance Imaging multi-resolution tractography |
Type |
Journal Article |
|
Year |
2013 |
Publication |
Revista Española de Cardiología |
Abbreviated Journal |
REC |
|
|
Volume |
66 |
Issue |
10 |
Pages |
782-790 |
|
|
Keywords |
Heart;Diffusion magnetic resonance imaging;Diffusion tractography;Helical heart;Myocardial ventricular band. |
|
|
Abstract |
Deep understanding of myocardial structure linking morphology and function of the heart would unravel crucial knowledge for medical and surgical clinical procedures and studies. Several conceptual models of myocardial fiber organization have been proposed but the lack of an automatic and objective methodology prevented an agreement. We sought to deepen in this knowledge through advanced computer graphic representations of the myocardial fiber architecture by diffusion tensor magnetic resonance imaging (DT-MRI).
We performed automatic tractography reconstruction of unsegmented DT-MRI canine heart datasets coming from the public database of the Johns Hopkins University. Full scale tractographies have been build with 200 seeds and are composed by streamlines computed on the vectorial field of primary eigenvectors given at the diffusion tensor volumes. Also, we introduced a novel multi-scale visualization technique in order to obtain a simplified tractography. This methodology allowed to keep the main geometric features of the fiber tracts, making easier to decipher the main properties of the architectural organization of the heart.
On the analysis of the output from our tractographic representations we found exact correlation with low-level details of myocardial architecture, but also with the more abstract conceptualization of a continuous helical ventricular myocardial fiber array.
Objective analysis of myocardial architecture by an automated method, including the entire myocardium and using several 3D levels of complexity, reveals a continuous helical myocardial fiber arrangement of both right and left ventricles, supporting the anatomical model of the helical ventricular myocardial band described by Torrent-Guasp. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Elsevier |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; 600.044; 600.060 |
Approved |
no |
|
|
Call Number |
IAM @ iam @ PGM2013 |
Serial |
2194 |
|
Permanent link to this record |
|
|
|
|
Author |
Aura Hernandez-Sabate; Debora Gil;Eduard Fernandez-Nofrerias;Petia Radeva; Enric Marti |
|
|
Title |
Approaching Artery Rigid Dynamics in IVUS |
Type |
Journal Article |
|
Year |
2009 |
Publication |
IEEE Transactions on Medical Imaging |
Abbreviated Journal |
TMI |
|
|
Volume |
28 |
Issue |
11 |
Pages |
1670-1680 |
|
|
Keywords |
Fourier analysis; intravascular ultrasound (IVUS) dynamics; longitudinal motion; quality measures; tissue deformation. |
|
|
Abstract |
Tissue biomechanical properties (like strain and stress) are playing an increasing role in diagnosis and long-term treatment of intravascular coronary diseases. Their assessment strongly relies on estimation of vessel wall deformation. Since intravascular ultrasound (IVUS) sequences allow visualizing vessel morphology and reflect its dynamics, this technique represents a useful tool for evaluation of tissue mechanical properties. Image misalignment introduced by vessel-catheter motion is a major artifact for a proper tracking of tissue deformation. In this work, we focus on compensating and assessing IVUS rigid in-plane motion due to heart beating. Motion parameters are computed by considering both the vessel geometry and its appearance in the image. Continuum mechanics laws serve to introduce a novel score measuring motion reduction in in vivo sequences. Synthetic experiments validate the proposed score as measure of motion parameters accuracy; whereas results in in vivo pullbacks show the reliability of the presented methodologies in clinical cases. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0278-0062 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ HGF2009 |
Serial |
1545 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Carles Sanchez; Agnes Borras; Marta Diez-Ferrer; Antoni Rosell |
|
|
Title |
Segmentation of Distal Airways using Structural Analysis |
Type |
Journal Article |
|
Year |
2019 |
Publication |
PloS one |
Abbreviated Journal |
Plos |
|
|
Volume |
14 |
Issue |
12 |
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
Segmentation of airways in Computed Tomography (CT) scans is a must for accurate support of diagnosis and intervention of many pulmonary disorders. In particular, lung cancer diagnosis would benefit from segmentations reaching most distal airways. We present a method that combines descriptors of bronchi local appearance and graph global structural analysis to fine-tune thresholds on the descriptors adapted for each bronchial level. We have compared our method to the top performers of the EXACT09 challenge and to a commercial software for biopsy planning evaluated in an own-collected data-base of high resolution CT scans acquired under different breathing conditions. Results on EXACT09 data show that our method provides a high leakage reduction with minimum loss in airway detection. Results on our data-base show the reliability across varying breathing conditions and a competitive performance for biopsy planning compared to a commercial solution. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; 600.139; 600.145 |
Approved |
no |
|
|
Call Number |
Admin @ si @ GSB2019 |
Serial |
3357 |
|
Permanent link to this record |
|
|
|
|
Author |
Marta Diez-Ferrer; Debora Gil; Elena Carreño; Susana Padrones; Samantha Aso |
|
|
Title |
Positive Airway Pressure-Enhanced CT to Improve Virtual Bronchoscopic Navigation |
Type |
Journal Article |
|
Year |
2017 |
Publication |
Journal of Thoracic Oncology |
Abbreviated Journal |
JTO |
|
|
Volume |
12 |
Issue |
1S |
Pages |
S596-S597 |
|
|
Keywords |
Thorax CT; diagnosis; Peripheral Pulmonary Nodule |
|
|
Abstract |
A main weakness of virtual bronchoscopic navigation (VBN) is unsuccessful segmentation of distal branches approaching peripheral pulmonary nodules (PPN). CT scan acquisition protocol is pivotal for segmentation covering the utmost periphery. We hypothesize that application of continuous positive airway pressure (CPAP) during CT acquisition could improve visualization and segmentation of peripheral bronchi. The purpose of the present pilot study is to compare quality of segmentations under 4 CT acquisition modes: inspiration (INSP), expiration (EXP) and both with CPAP (INSP-CPAP and EXP-CPAP). |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; 600.096; 600.075; 600.145 |
Approved |
no |
|
|
Call Number |
Admin @ si @ DGC2017a |
Serial |
2883 |
|
Permanent link to this record |
|
|
|
|
Author |
Oriol Rodriguez-Leon; Josefina Mauri;Eduard Fernandez-Nofrerias; Antonio Tovar; Vicente del Valle; Aura Hernandez-Sabate; Debora Gil; Petia Radeva |
|
|
Title |
Utilizacion de la estructura de los campos vectoriales para la deteccion de la Adventicia en imagenes de Ecografia Intracoronaria |
Type |
Journal |
|
Year |
2004 |
Publication |
Revista Española de Cardiología |
Abbreviated Journal |
REC |
|
|
Volume |
57 |
Issue |
2 |
Pages |
100 |
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
SEC |
|
|
Notes |
MILAB;IAM |
Approved |
no |
|
|
Call Number |
BCNPCL @ bcnpcl @ RMF2004 |
Serial |
566 |
|
Permanent link to this record |
|
|
|
|
Author |
Francesc Carreras; Jaume Garcia; Debora Gil; Sandra Pujadas; Chi ho Lion; R.Suarez-Arias; R.Leta; Xavier Alomar; Manuel Ballester; Guillem Pons-Llados |
|
|
Title |
Left ventricular torsion and longitudinal shortening: two fundamental components of myocardial mechanics assessed by tagged cine-MRI in normal subjects |
Type |
Journal Article |
|
Year |
2012 |
Publication |
International Journal of Cardiovascular Imaging |
Abbreviated Journal |
IJCI |
|
|
Volume |
28 |
Issue |
2 |
Pages |
273-284 |
|
|
Keywords |
Magnetic resonance imaging (MRI); Tagging MRI; Cardiac mechanics; Ventricular torsion |
|
|
Abstract |
Cardiac magnetic resonance imaging (Cardiac MRI) has become a gold standard diagnostic technique for the assessment of cardiac mechanics, allowing the non-invasive calculation of left ventric- ular long axis longitudinal shortening (LVLS) and absolute myocardial torsion (AMT) between basal and apical left ventricular slices, a movement directly related to the helicoidal anatomic disposition of the myocardial fibers. The aim of this study is to determine AMT and LVLS behaviour and normal values from a group of healthy subjects. A group of 21 healthy volunteers (15 males) (age: 23–55 y.o., mean:30.7 ± 7.5) were prospectively included in an obser- vational study by Cardiac MRI. Left ventricular rotation (degrees) was calculated by custom-made software (Harmonic Phase Flow) in consecutive LV short axis planes tagged cine-MRI sequences. AMT was determined from the difference between basal and apical planes LV rotations. LVLS (%) was determined from the LV longitudinal and horizontal axis cine-MRI images. All the 21 cases studied were interpretable, although in three cases the value of the LV apical rotation could not be determined. The mean rotation of the basal and apical planes at end-systole were -3.71° ± 0.84° and 6.73° ± 1.69° (n:18) respectively, resulting in a LV mean AMT of 10.48° ± 1.63° (n:18). End-systolic mean LVLS was 19.07 ± 2.71%. Cardiac MRI allows for the calculation of AMT and LVLS, fundamental functional components of the ventricular twist mechanics conditioned, in turn, by the anatomical helical layout of the myocardial fibers. These values provide complementary information about systolic ventricular function in relation to the traditional parameters used in daily practice. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Netherlands |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1569-5794 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ CGG2012 |
Serial |
1496 |
|
Permanent link to this record |
|
|
|
|
Author |
Oriol Rodriguez-Leon; Debora Gil; Eduard Fernandez-Nofrerias |
|
|
Title |
Analisis en los cambios en el nivel de gris en las secuencias angiograficas mediante descriptores estadisticos para determinar la perfusion miocardica |
Type |
Journal Article |
|
Year |
2006 |
Publication |
Revista Española de Cardiología |
Abbreviated Journal |
REC |
|
|
Volume |
59 Supl 2-166 |
Issue |
2 |
Pages |
128 |
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RGF2006 |
Serial |
1640 |
|
Permanent link to this record |