|
Records |
Links |
|
Author |
Debora Gil; Agnes Borras; Manuel Ballester; Francesc Carreras; Ruth Aris; Manuel Vazquez; Enric Marti; Ferran Poveda |
|
|
Title |
MIOCARDIA: Integrating cardiac function and muscular architecture for a better diagnosis |
Type |
Conference Article |
|
Year |
2011 |
Publication |
14th International Symposium on Applied Sciences in Biomedical and Communication Technologies |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
Deep understanding of myocardial structure of the heart would unravel crucial knowledge for clinical and medical procedures. The MIOCARDIA project is a multidisciplinary project in cooperation with l'Hospital de la Santa Creu i de Sant Pau, Clinica la Creu Blanca and Barcelona Supercomputing Center. The ultimate goal of this project is defining a computational model of the myocardium. The model takes into account the deep interrelation between the anatomy and the mechanics of the heart. The paper explains the workflow of the MIOCARDIA project. It also introduces a multiresolution reconstruction technique based on DT-MRI streamlining for simplified global myocardial model generation. Our reconstructions can restore the most complex myocardial structures and provides evidences of a global helical organization. |
|
|
Address |
Barcelona; Spain |
|
|
Corporate Author |
Association for Computing Machinery |
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Barcelona, Spain |
Editor |
Association for Computing Machinery |
|
|
Language |
english |
Summary Language |
english |
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-1-4503-0913-4 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ISABEL |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GGB2011 |
Serial |
1691 |
|
Permanent link to this record |
|
|
|
|
Author |
Patricia Marquez; Debora Gil; Aura Hernandez-Sabate |
|
|
Title |
A Confidence Measure for Assessing Optical Flow Accuracy in the Absence of Ground Truth |
Type |
Conference Article |
|
Year |
2011 |
Publication |
IEEE International Conference on Computer Vision – Workshops |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
2042-2049 |
|
|
Keywords |
IEEE International Conference on Computer Vision – Workshops |
|
|
Abstract |
Optical flow is a valuable tool for motion analysis in autonomous navigation systems. A reliable application requires determining the accuracy of the computed optical flow. This is a main challenge given the absence of ground truth in real world sequences. This paper introduces a measure of optical flow accuracy for Lucas-Kanade based flows in terms of the numerical stability of the data-term. We call this measure optical flow condition number. A statistical analysis over ground-truth data show a good statistical correlation between the condition number and optical flow error. Experiments on driving sequences illustrate its potential for autonomous navigation systems. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
IEEE |
Place of Publication |
Barcelona (Spain) |
Editor |
|
|
|
Language |
English |
Summary Language |
English |
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ICCVW |
|
|
Notes |
IAM; ADAS |
Approved |
no |
|
|
Call Number |
IAM @ iam @ MGH2011 |
Serial |
1682 |
|
Permanent link to this record |
|
|
|
|
Author |
Patricia Marquez; Debora Gil; Aura Hernandez-Sabate |
|
|
Title |
Evaluation of the Capabilities of Confidence Measures for Assessing Optical Flow Quality |
Type |
Conference Article |
|
Year |
2013 |
Publication |
ICCV Workshop on Computer Vision in Vehicle Technology: From Earth to Mars |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
624-631 |
|
|
Keywords |
|
|
|
Abstract |
Assessing Optical Flow (OF) quality is essential for its further use in reliable decision support systems. The absence of ground truth in such situations leads to the computation of OF Confidence Measures (CM) obtained from either input or output data. A fair comparison across the capabilities of the different CM for bounding OF error is required in order to choose the best OF-CM pair for discarding points where OF computation is not reliable. This paper presents a statistical probabilistic framework for assessing the quality of a given CM. Our quality measure is given in terms of the percentage of pixels whose OF error bound can not be determined by CM values. We also provide statistical tools for the computation of CM values that ensures a given accuracy of the flow field. |
|
|
Address |
Sydney; Australia; December 2013 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
CVTT:E2M |
|
|
Notes |
IAM; ADAS; 600.044; 600.057; 601.145 |
Approved |
no |
|
|
Call Number |
Admin @ si @ MGH2013b |
Serial |
2351 |
|
Permanent link to this record |
|
|
|
|
Author |
Albert Andaluz; Francesc Carreras; Cristina Santa Marta;Debora Gil |
|
|
Title |
Myocardial torsion estimation with Tagged-MRI in the OsiriX platform |
Type |
Conference Article |
|
Year |
2012 |
Publication |
ISBI Workshop on Open Source Medical Image Analysis software |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
Myocardial torsion (MT) plays a crucial role in the assessment of the functionality of the
left ventricle. For this purpose, the IAM group at the CVC has developed the Harmonic Phase Flow (HPF) plugin for the Osirix DICOM platform . We have validated its funcionalty on sequences acquired using different protocols and including healthy and pathological cases. Results show similar torsion trends for SPAMM acquisitions, with pathological cases introducing expected deviations from the ground truth. Finally, we provide the plugin free of charge at http://iam.cvc.uab.es |
|
|
Address |
Barcelona, Spain |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
IEEE |
Place of Publication |
|
Editor |
Wiro Niessen (Erasmus MC) and Marc Modat (UCL) |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ISBI |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ ACS2012 |
Serial |
1900 |
|
Permanent link to this record |
|
|
|
|
Author |
Jaume Garcia; Debora Gil; Francesc Carreras; Sandra Pujades; R.Leta; Xavier Alomar; Guillem Pons-LLados |
|
|
Title |
Patrons de Normalitat Regional per la Valoració de la Funció del Ventricle Esquerre |
Type |
Conference Article |
|
Year |
2008 |
Publication |
XX Congrés de la Societat Catalana de Cardiologia |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
60 |
|
|
Keywords |
|
|
|
Abstract |
Les malalties cardiovasculars afecten les propietats contràctils de la banda ventricular i provoquen una variació de la funció del Ventricle Esquerre (VE) . Només els indicadors locals (strains, la deformació del teixit) són capaços de detectar anomalies en territoris específics del VE . Patrons de normalitat regionals d’aquests paràmetres serien d’utilitat a l’hora de valorar-ne la funció .
Presentem un Domini Paramètric Normalitzat (DPN) que permet comparar dades de diferents pacients i definir Patrons de Normalitat Regional (PNR) |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Barcelona |
Editor |
|
|
|
Language |
catalan |
Summary Language |
catalan |
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GGC2008b |
Serial |
1503 |
|
Permanent link to this record |
|
|
|
|
Author |
Patricia Marquez; Debora Gil; Aura Hernandez-Sabate; Daniel Kondermann |
|
|
Title |
When Is A Confidence Measure Good Enough? |
Type |
Conference Article |
|
Year |
2013 |
Publication |
9th International Conference on Computer Vision Systems |
Abbreviated Journal |
|
|
|
Volume |
7963 |
Issue |
|
Pages |
344-353 |
|
|
Keywords |
Optical flow, confidence measure, performance evaluation |
|
|
Abstract |
Confidence estimation has recently become a hot topic in image processing and computer vision.Yet, several definitions exist of the term “confidence” which are sometimes used interchangeably. This is a position paper, in which we aim to give an overview on existing definitions,
thereby clarifying the meaning of the used terms to facilitate further research in this field. Based on these clarifications, we develop a theory to compare confidence measures with respect to their quality. |
|
|
Address |
St Petersburg; Russia; July 2013 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Link |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0302-9743 |
ISBN |
978-3-642-39401-0 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
ICVS |
|
|
Notes |
IAM;ADAS; 600.044; 600.057; 600.060; 601.145 |
Approved |
no |
|
|
Call Number |
IAM @ iam @ MGH2013a |
Serial |
2218 |
|
Permanent link to this record |
|
|
|
|
Author |
Sergio Vera; Miguel Angel Gonzalez Ballester; Debora Gil |
|
|
Title |
A Novel Cochlear Reference Frame Based On The Laplace Equation |
Type |
Conference Article |
|
Year |
2015 |
Publication |
29th international Congress and Exhibition on Computer Assisted Radiology and Surgery |
Abbreviated Journal |
|
|
|
Volume |
10 |
Issue |
1 |
Pages |
1-312 |
|
|
Keywords |
|
|
|
Abstract |
Poster |
|
|
Address |
Barcelona; Spain; June 2015 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
CARS |
|
|
Notes |
IAM; 600.075 |
Approved |
no |
|
|
Call Number |
Admin @ si @ VGG2015 |
Serial |
2615 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Jaume Garcia; Aura Hernandez-Sabate; Enric Marti |
|
|
Title |
Manifold parametrization of the left ventricle for a statistical modelling of its complete anatomy |
Type |
Conference Article |
|
Year |
2010 |
Publication |
8th Medical Imaging |
Abbreviated Journal |
|
|
|
Volume |
7623 |
Issue |
762304 |
Pages |
304 |
|
|
Keywords |
|
|
|
Abstract |
Distortion of Left Ventricle (LV) external anatomy is related to some dysfunctions, such as hypertrophy. The architecture of myocardial fibers determines LV electromechanical activation patterns as well as mechanics. Thus, their joined modelling would allow the design of specific interventions (such as peacemaker implantation and LV remodelling) and therapies (such as resynchronization). On one hand, accurate modelling of external anatomy requires either a dense sampling or a continuous infinite dimensional approach, which requires non-Euclidean statistics. On the other hand, computation of fiber models requires statistics on Riemannian spaces. Most approaches compute separate statistical models for external anatomy and fibers architecture. In this work we propose a general mathematical framework based on differential geometry concepts for computing a statistical model including, both, external and fiber anatomy. Our framework provides a continuous approach to external anatomy supporting standard statistics. We also provide a straightforward formula for the computation of the Riemannian fiber statistics. We have applied our methodology to the computation of complete anatomical atlas of canine hearts from diffusion tensor studies. The orientation of fibers over the average external geometry agrees with the segmental description of orientations reported in the literature. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
SPIE |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
SPIE |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GGH2010a |
Serial |
1522 |
|
Permanent link to this record |
|
|
|
|
Author |
Aura Hernandez-Sabate; Monica Mitiko; Sergio Shiguemi; Debora Gil |
|
|
Title |
A validation protocol for assessing cardiac phase retrieval in IntraVascular UltraSound |
Type |
Conference Article |
|
Year |
2010 |
Publication |
Computing in Cardiology |
Abbreviated Journal |
|
|
|
Volume |
37 |
Issue |
|
Pages |
899-902 |
|
|
Keywords |
|
|
|
Abstract |
A good reliable approach to cardiac triggering is of utmost importance in obtaining accurate quantitative results of atherosclerotic plaque burden from the analysis of IntraVascular UltraSound. Although, in the last years, there has been an increase in research of methods for retrospective gating, there is no general consensus in a validation protocol. Many methods are based on quality assessment of longitudinal cuts appearance and those reporting quantitative numbers do not follow a standard protocol. Such heterogeneity in validation protocols makes faithful comparison across methods a difficult task. We propose a validation protocol based on the variability of the retrieved cardiac phase and explore the capability of several quality measures for quantifying such variability. An ideal detector, suitable for its application in clinical practice, should produce stable phases. That is, it should always sample the same cardiac cycle fraction. In this context, one should measure the variability (variance) of a candidate sampling with respect a ground truth (reference) sampling, since the variance would indicate how spread we are aiming a target. In order to quantify the deviation between the sampling and the ground truth, we have considered two quality scores reported in the literature: signed distance to the closest reference sample and distance to the right of each reference sample. We have also considered the residuals of the regression line of reference against candidate sampling. The performance of the measures has been explored on a set of synthetic samplings covering different cardiac cycle fractions and variabilities. From our simulations, we conclude that the metrics related to distances are sensitive to the shift considered while the residuals are robust against fraction and variabilities as far as one can establish a pair-wise correspondence between candidate and reference. We will further investigate the impact of false positive and negative detections in experimental data. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
IEEE |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0276-6547 |
ISBN |
978-1-4244-7318-2 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
CINC |
|
|
Notes |
IAM; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ HSM2010 |
Serial |
1551 |
|
Permanent link to this record |
|
|
|
|
Author |
Jaume Garcia; Albert Andaluz; Debora Gil; Francesc Carreras |
|
|
Title |
Decoupled External Forces in a Predictor-Corrector Segmentation Scheme for LV Contours in Tagged MR Images |
Type |
Conference Article |
|
Year |
2010 |
Publication |
32nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
4805-4808 |
|
|
Keywords |
|
|
|
Abstract |
Computation of functional regional scores requires proper identification of LV contours. On one hand, manual segmentation is robust, but it is time consuming and requires high expertise. On the other hand, the tag pattern in TMR sequences is a problem for automatic segmentation of LV boundaries. We propose a segmentation method based on a predictorcorrector (Active Contours – Shape Models) scheme. Special stress is put in the definition of the AC external forces. First, we introduce a semantic description of the LV that discriminates myocardial tissue by using texture and motion descriptors. Second, in order to ensure convergence regardless of the initial contour, the external energy is decoupled according to the orientation of the edges in the image potential. We have validated the model in terms of error in segmented contours and accuracy of regional clinical scores. |
|
|
Address |
Buenos Aires (Argentina) |
|
|
Corporate Author |
IEEE EMB |
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1557-170X |
ISBN |
978-1-4244-4123-5 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
EMBC |
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GAG2010 |
Serial |
1514 |
|
Permanent link to this record |