Cristina Cañero and 16 others. 1999. Optimal Stent Implantation: Three-dimensional Evaluation of the Mutual Position of Stent and Vessel via Intracoronary Ecography. Proceedings of International Conference on Computer in Cardiology (CIC´99).
Abstract: We present a new automatic technique to visualize and quantify the mutual position between the stent and the vessel wall by considering their three-dimensional reconstruction. Two deformable generalized cylinders adapt to the image features in all IVUS planes corresponding to the vessel wall and the stent in order to reconstruct the boundaries of the stent and the vessel in space. The image features that characterize the stent and the vessel wall are determined in terms of edge and ridge image detectors taking into account the gray level of the image pixels. We show that the 30 reconstruction by deformable cylinders is accurate and robust due to the spatial data coherence in the considered volumetric IVUS image. The main clinic utility of the stent and vessel reconstruction by deformable’ cylinders consists of its possibility to visualize and to assess the optimal stent introduction.
|
|
|
Cristina Cañero and 16 others. 1999. Three-dimensional reconstruction and quantification of the coronary tree using intravascular ultrasound images. Proceedings of International Conference on Computer in Cardiology (CIC´99).
Abstract: In this paper we propose a new Computer Vision technique to reconstruct the vascular wall in space using a deformable model-based technique and compounding methods, based in biplane angiography and intravascular ultrasound data jicsion. It is also proposed a generalpurpose three-dimensional guided interpolation method. The three dimensional centerline of the vessel is reconstructed from geometrically corrected biplane angiographies using automatic segmentation methods and snakes. The IVUS image planes are located in the threedimensional space and correctly oriented. A led interpolation method based in B-SurJaces and snakes isused to fill the gaps among image planes
|
|
|
M.Gomez and 6 others. 2002. Reconstrucción de un modelo espacio-temporal de la luz del vaso a partir de secuencias de ecografía intracoronaria. XXXVIII Congreso Nacional de la Sociedad Española de Cardiología..
|
|
|
Josefina Mauri and 14 others. 2000. Moviment del vas en l anàlisi d imatges d ecografia intracoronària: un model matemàtic. Congrés de la Societat Catalana de Cardiologia..
|
|
|
Josefina Mauri and 14 others. 2000. Avaluació del Conjunt Stent/Artèria mitjançant ecografia intracoronària: lentorn informàtic. Congrés de la Societat Catalana de Cardiologia..
|
|
|
Petia Radeva, Joan Serrat and Enric Marti. 1995. A snake for model-based segmentation. Proc. Conf. Fifth Int Computer Vision.816–821.
Abstract: Despite the promising results of numerous applications, the hitherto proposed snake techniques share some common problems: snake attraction by spurious edge points, snake degeneration (shrinking and attening), convergence and stability of the deformation process, snake initialization and local determination of the parameters of elasticity. We argue here that these problems can be solved only when all the snake aspects are considered. The snakes proposed here implement a new potential eld and external force in order to provide a deformation convergence, attraction by both near and far edges as well as snake behaviour selective according to the edge orientation. Furthermore, we conclude that in the case of model-based seg mentation, the internal force should include structural information about the expected snake shape. Experiments using this kind of snakes for segmenting bones in complex hand radiographs show a signicant improvement.
Keywords: snakes; elastic matching; model-based segmenta tion
|
|
|
Oriol Rodriguez-Leon and 10 others. 2002. Ecografia Intracoronària: Segmentació Automàtica de area de la llum. XXXVIII Congreso Nacional de la Sociedad Española de Cardiología..
|
|
|
Joan Serrat and Enric Marti. 1991. Elastic matching using interpolation splines. IV Spanish Symposium of Pattern Recognition and image Analysis.
|
|
|
Ernest Valveny, Ricardo Toledo, Ramon Baldrich and Enric Marti. 2002. Combining recognition-based in segmentation-based approaches for graphic symol recognition using deformable template matching. Proceeding of the Second IASTED International Conference Visualization, Imaging and Image Proceesing VIIP 2002.502–507.
|
|
|
Patricia Marquez, Debora Gil and Aura Hernandez-Sabate. 2011. A Confidence Measure for Assessing Optical Flow Accuracy in the Absence of Ground Truth. IEEE International Conference on Computer Vision – Workshops. Barcelona (Spain), IEEE, 2042–2049.
Abstract: Optical flow is a valuable tool for motion analysis in autonomous navigation systems. A reliable application requires determining the accuracy of the computed optical flow. This is a main challenge given the absence of ground truth in real world sequences. This paper introduces a measure of optical flow accuracy for Lucas-Kanade based flows in terms of the numerical stability of the data-term. We call this measure optical flow condition number. A statistical analysis over ground-truth data show a good statistical correlation between the condition number and optical flow error. Experiments on driving sequences illustrate its potential for autonomous navigation systems.
Keywords: IEEE International Conference on Computer Vision – Workshops
|
|