Cristina Cañero, Petia Radeva, Oriol Pujol, Ricardo Toledo, Debora Gil, J. Saludes, et al. (1999). "Optimal Stent Implantation: Three-dimensional Evaluation of the Mutual Position of Stent and Vessel via Intracoronary Ecography " In Proceedings of International Conference on Computer in Cardiology (CIC´99).
Abstract: We present a new automatic technique to visualize and quantify the mutual position between the stent and the vessel wall by considering their three-dimensional reconstruction. Two deformable generalized cylinders adapt to the image features in all IVUS planes corresponding to the vessel wall and the stent in order to reconstruct the boundaries of the stent and the vessel in space. The image features that characterize the stent and the vessel wall are determined in terms of edge and ridge image detectors taking into account the gray level of the image pixels. We show that the 30 reconstruction by deformable cylinders is accurate and robust due to the spatial data coherence in the considered volumetric IVUS image. The main clinic utility of the stent and vessel reconstruction by deformable’ cylinders consists of its possibility to visualize and to assess the optimal stent introduction.
|
|
|
Cristina Cañero, Petia Radeva, Oriol Pujol, Ricardo Toledo, Debora Gil, J. Saludes, et al. (1999). "Three-dimensional reconstruction and quantification of the coronary tree using intravascular ultrasound images " In Proceedings of International Conference on Computer in Cardiology (CIC´99).
Abstract: In this paper we propose a new Computer Vision technique to reconstruct the vascular wall in space using a deformable model-based technique and compounding methods, based in biplane angiography and intravascular ultrasound data jicsion. It is also proposed a generalpurpose three-dimensional guided interpolation method. The three dimensional centerline of the vessel is reconstructed from geometrically corrected biplane angiographies using automatic segmentation methods and snakes. The IVUS image planes are located in the threedimensional space and correctly oriented. A led interpolation method based in B-SurJaces and snakes isused to fill the gaps among image planes
|
|
|
Debora Gil, Petia Radeva, Jordi Saludes, & J. Mauri. (2000). "Automatic Segmentation of Artery Wall in Coronary IVUS Images: A Probabilistic Approach " In International Conference on Pattern Recognition (Vol. 4, pp. 352–355).
Abstract: Intravascular ultrasound images represent a unique tool to analyze the morphology of arteries and vessels (plaques, restenosis, etc). The poor quality of these images makes unsupervised segmentation based on traditional segmentation algorithms (such as edge or ridge/valley detection) fail to achieve the expected results. In this paper we present a probabilistic flexible template to separate different regions in the image. In particular, we use elliptic templates to model and detect the shape of the vessel inner wall in IVUS images. We present the results of successful segmentation obtained from patients undergoing stent treatment. A physician team has validated these results.
|
|
|
Debora Gil, Petia Radeva, Jordi Saludes, & J. Mauri. (2000). "Automatic Segmentation of Artery Wall in Coronary IVUS Images: a Probabilistic Approach " In Proceedings of CIC’2000. Cambridge, Massachussets.
Abstract: Intravascular ultrasound images represent a unique tool to analyze the morphology of arteries and vessels (plaques, restenosis, etc). The poor quality of these images makes unsupervised segmentation based on traditional segmentation algorithms (such as edge or ridge/valley detection) fail to achieve the expected results. In this paper we present a probabilistic flexible template to separate different regions in the image. In particular, we use elliptic templates to model and detect the shape of the vessel inner wall in IVUS images. We present the results of successful segmentation obtained from patients undergoing stent treatment. A physician team has validated these results.
|
|
|
J. Mauri, Eduard Fernandez-Nofrerias, B. Garcia del Blanco, E. Iraculis, J.A. Gomez-Hospital, J. Comin, et al. (2000)." Moviment del vas en l anàlisi d imatges d ecografia intracoronària: un model matemàtic" In Congrés de la Societat Catalana de Cardiologia..
|
|
|
J. Mauri, Eduard Fernandez-Nofrerias, J. Comin, B. Garcia del Blanco, E. Iraculis, J.A. Gomez-Hospital, et al. (2000)." Avaluació del Conjunt Stent/Artèria mitjançant ecografia intracoronària: lentorn informàtic" In Congrés de la Societat Catalana de Cardiologia..
|
|
|
Oriol Rodriguez-Leor, J. Mauri, Eduard Fernandez-Nofrerias, M. Gomez, Antonio Tovar, L. Cano, et al. (2002)." Ecografia Intracoronaria: Segmentacio Automatica de area de la llum" . Revista Societat Catalana de Cardiologia, 4(4), 42.
|
|
|
M. Gomez, J. Mauri, Eduard Fernandez-Nofrerias, Oriol Rodriguez-Leor, Carme Julia, Debora Gil, et al. (2002)." Reconstrucción de un modelo espacio-temporal de la luz del vaso a partir de secuencias de ecografía intracoronaria" In XXXVIII Congreso Nacional de la Sociedad Española de Cardiología..
|
|
|
Debora Gil. (2002)." Regularized Curvature Flow" . Computer Vision Centre.
|
|
|
Debora Gil, Petia Radeva, & J. Mauri. (2002). "Ivus Segmentation Via a Regularized Curvature Flow " In X Congreso Anual de la Sociedad Española de Ingeniería Biomédica CASEIB 2002 (pp. 133–136). Saragossa, Espanya.
Abstract: Cardiac diseases are diagnosed and treated through a study of the morphology and dynamics of cardiac arteries. In- travascular Ultrasound (IVUS) imaging is of high interest to physicians since it provides both information. At the current state-of-the-art in image segmentation, a robust detection of the arterial lumen in IVUS demands manual intervention or ECG-gating. Manual intervention is a tedious and time consuming task that requires experienced observers, meanwhile ECG-gating is an acquisition technique not available in all clinical centers. We introduce a parametric algorithm that detects the arterial luminal border in in vivo sequences. The method consist in smoothing the sequences’ level surfaces under a regularized mean curvature flow that admits non-trivial steady states. The flow is based on a measure of the surface local smoothness that takes into account regularity of the surface curvature.
|
|