|
Oriol Pujol, Debora Gil, & Petia Radeva. (2005). "Fundamentals of Stop and Go active models " . Image and Vision Computing, 23(8), 681–691.
Abstract: An efficient snake formulation should conform to the idea of picking the smoothest curve among all the shapes approximating an object of interest. In current geodesic snakes, the regularizing curvature also affects the convergence stage, hindering the latter at concave regions. In the present work, we make use of characteristic functions to define a novel geodesic formulation that decouples regularity and convergence. This term decoupling endows the snake with higher adaptability to non-convex shapes. Convergence is ensured by splitting the definition of the external force into an attractive vector field and a repulsive one. In our paper, we propose to use likelihood maps as approximation of characteristic functions of object appearance. The better efficiency and accuracy of our decoupled scheme are illustrated in the particular case of feature space-based segmentation.
Keywords: Deformable models; Geodesic snakes; Region-based segmentation
|
|
|
Oriol Rodriguez-Leor, A. Carol, H. Tizon, Eduard Fernandez-Nofrerias, Josefina Mauri, Vicente del Valle, et al. (2005)." Model estadístic-determinístic per la segmentació de l adventicia en imatges d ecografía intracoronaria" . Rev Societat Catalana Cardiologia, 5, 41.
|
|
|
Misael Rosales, Petia Radeva, Oriol Rodriguez, & Debora Gil. (2005). "Suppression of IVUS Image Rotation. A Kinematic Approach " In Monica Andres and Hernandez Petia and Santos A. and R. Frangi (Ed.), Functional Imaging and Modeling of the Heart (Vol. 3504, pp. 889–892). Lecture Notes in Computer Science, 3504. Springer Berlin / Heidelberg.
Abstract: IntraVascular Ultrasound (IVUS) is an exploratory technique used in interventional procedures that shows cross section images of arteries and provides qualitative information about the causes and severity of the arterial lumen narrowing. Cross section analysis as well as visualization of plaque extension in a vessel segment during the catheter imaging pullback are the technique main advantages. However, IVUS sequence exhibits a periodic rotation artifact that makes difficult the longitudinal lesion inspection and hinders any segmentation algorithm. In this paper we propose a new kinematic method to estimate and remove the image rotation of IVUS images sequences. Results on several IVUS sequences show good results and prompt some of the clinical applications to vessel dynamics study, and relation to vessel pathology.
|
|
|
Enric Marti, Debora Gil, & Carme Julia. (2006)." Una experiencia de PBL en la docencia de la asignatura de Graficos por Computador en Ingenieria Informatica" (Vol. 1).
|
|
|
Enric Marti, Carme Julia, & Debora Gil. (2006)." Una experiencia de PBL en la docencia de la asignatura de Graficos por Computador en Ingenieria Informatica" .
|
|
|
Jaume Garcia, Debora Gil, Joel Barajas, Francesc Carreras, Sandra Pujades, & Petia Radeva. (2006). "Characterization of ventricular torsion in healthy subjects using Gabor filters and a variational framework " In Proc. Computers in Cardiology (pp. 877–880).
Abstract: In this work, we present a fully automated method for tissue deformation estimation in tagged magnetic resonance images (TMRI). Gabor filter banks, tuned independently for each left ventricle level, provide optimally filtered complex images which phase remains constant along the cardiac cycle. This fact can be thought as the brightness constancy condition required by classical optical flow (OF) methods. Pairs of these filtered sequences, together with a variational formulation are used in a second step to obtain dense continuous deformation maps that we call Harmonic Phase Flow. This method has been used to determine reference values of ventricular torsion (VT) in a set of 8 healthy volunteers. The results encourage the use of VT as a useful parameter for ventricular function assessment in clinical routine.
|
|
|
Debora Gil, Jose Maria-Carazo, & Roberto Marabini. (2006). "On the nature of 2D crystal unbending " . Journal of Structural Biology, 156(3), 546–555.
Abstract: Crystal unbending, the process that aims to recover a perfect crystal from experimental data, is one of the more important steps in electron crystallography image processing. The unbending process involves three steps: estimation of the unit cell displacements from their ideal positions, extension of the deformation field to the whole image and transformation of the image in order to recover an ideal crystal. In this work, we present a systematic analysis of the second step oriented to address two issues. First, whether the unit cells remain undistorted and only the distance between them should be changed (rigid case) or should be modified with the same deformation suffered by the whole crystal (elastic case). Second, the performance of different extension algorithms (interpolation versus approximation) is explored. Our experiments show that there is no difference between elastic and rigid cases or among the extension algorithms. This implies that the deformation fields are constant over large areas. Furthermore, our results indicate that the main source of error is the transformation of the crystal image.
Keywords: Electron microscopy
|
|
|
Debora Gil, Aura Hernandez-Sabate, Oriol Rodriguez, Josepa Mauri, & Petia Radeva. (2006). "Statistical Strategy for Anisotropic Adventitia Modelling in IVUS " . IEEE Transactions on Medical Imaging, 25(6), 768–778.
Abstract: Vessel plaque assessment by analysis of intravascular ultrasound sequences is a useful tool for cardiac disease diagnosis and intervention. Manual detection of luminal (inner) and mediaadventitia (external) vessel borders is the main activity of physicians in the process of lumen narrowing (plaque) quantification. Difficult definition of vessel border descriptors, as well as, shades, artifacts, and blurred signal response due to ultrasound physical properties trouble automated adventitia segmentation. In order to efficiently approach such a complex problem, we propose blending advanced anisotropic filtering operators and statistical classification techniques into a vessel border modelling strategy. Our systematic statistical analysis shows that the reported adventitia detection achieves an accuracy in the range of interobserver variability regardless of plaque nature, vessel geometry, and incomplete vessel borders. Index Terms–-Anisotropic processing, intravascular ultrasound (IVUS), vessel border segmentation, vessel structure classification.
Keywords: Corners; T-junctions; Wavelets
|
|
|
Debora Gil, Oriol Rodriguez, Josepa Mauri, & Petia Radeva. (2006)." Statistical descriptors of the Myocardial perfusion in angiographic images" In Proc. Computers in Cardiology (pp. 677–680).
Abstract: Restoration of coronary flow after primary percutaneous coronary intervention in acute myocardial infarction does not always correlate with adequate myocardial perfusion. Recently, coronary angiography has been used to assess microcirculation integrity (Myocardial BlushAnalysis, MBA). Although MBA correlates with patient prognosis there are few image processing methods addressing objective perfusion quantification. The goal of this work is to develop statistical descriptors of the myocardial dyeing pattern allowing objective assessment of myocardial perfusion. Experiments on healthy right coronary arteries show that our approach allows reliable measurements without any specific image acquisition protocol.
Keywords: Anisotropic processing; intravascular ultrasound (IVUS); vessel border segmentation; vessel structure classification.
|
|
|
Debora Gil, & Petia Radeva. (2006). "Inhibition of false landmarks " . Pattern Recognition Letters, 27(9), 1022–1030.
Abstract: Corners and junctions are landmarks characterized by the lack of differentiability in the unit tangent to the image level curve. Detectors based on differential operators are not, by their own definition, the best posed as they require a higher degree of differentiability to yield a reliable response. We argue that a corner detector should be based on the degree of continuity of the tangent vector to the image level sets, work on the image domain and need no assumptions on neither the image local structure nor the particular geometry of the corner/junction. An operator measuring the degree of differentiability of the projection matrix on the image gradient fulfills the above requirements. Because using smoothing kernels leads to corner misplacement, we suggest an alternative fake response remover based on the receptive field inhibition of spurious details. The combination of both orientation discontinuity detection and noise inhibition produce our inhibition orientation energy (IOE) landmark locator.
|
|