Misael Rosales, Petia Radeva, Oriol Rodriguez, & Debora Gil. (2005). "Suppression of IVUS Image Rotation. A Kinematic Approach " In Monica Andres and Hernandez Petia and Santos A. and R. Frangi (Ed.), Functional Imaging and Modeling of the Heart (Vol. 3504, pp. 889–892). Lecture Notes in Computer Science, 3504. Springer Berlin / Heidelberg.
Abstract: IntraVascular Ultrasound (IVUS) is an exploratory technique used in interventional procedures that shows cross section images of arteries and provides qualitative information about the causes and severity of the arterial lumen narrowing. Cross section analysis as well as visualization of plaque extension in a vessel segment during the catheter imaging pullback are the technique main advantages. However, IVUS sequence exhibits a periodic rotation artifact that makes difficult the longitudinal lesion inspection and hinders any segmentation algorithm. In this paper we propose a new kinematic method to estimate and remove the image rotation of IVUS images sequences. Results on several IVUS sequences show good results and prompt some of the clinical applications to vessel dynamics study, and relation to vessel pathology.
|
|
|
Debora Gil, & Petia Radeva. (2004). "Inhibition of False Landmarks " In J. V. et al (Ed.), Recent Advances in Artificial Intelligence Research and Development (pp. 233–244). Barcelona (Spain): IOS Press.
Abstract: We argue that a corner detector should be based on the degree of continuity of the tangent vector to the image level sets, work on the image domain and need no assumptions on neither the image local structure nor the particular geometry of the corner/junction. An operator measuring the degree of differentiability of the projection matrix on the image gradient fulfills the above requirements. Its high sensitivity to changes in vector directions makes it suitable for landmark location in real images prone to need smoothing to reduce the impact of noise. Because using smoothing kernels leads to corner misplacement, we suggest an alternative fake response remover based on the receptive field inhibition of spurious details. The combination of both orientation discontinuity detection and noise inhibition produce our Inhibition Orientation Energy (IOE) landmark locator.
|
|
|
Fernando Vilariño, Debora Gil, & Petia Radeva. (2004). "A Novel FLDA Formulation for Numerical Stability Analysis " In P. R. and I. A. J. Vitrià (Ed.), Recent Advances in Artificial Intelligence Research and Development (Vol. 113, pp. 77–84). IOS Press.
Abstract: Fisher Linear Discriminant Analysis (FLDA) is one of the most popular techniques used in classification applying dimensional reduction. The numerical scheme involves the inversion of the within-class scatter matrix, which makes FLDA potentially ill-conditioned when it becomes singular. In this paper we present a novel explicit formulation of FLDA in terms of the eccentricity ratio and eigenvector orientations of the within-class scatter matrix. An analysis of this function will characterize those situations where FLDA response is not reliable because of numerical instability. This can solve common situations of poor classification performance in computer vision.
Keywords: Supervised Learning; Linear Discriminant Analysis; Numerical Stability; Computer Vision
|
|
|
Aura Hernandez-Sabate, & Debora Gil. (2012). "The Benefits of IVUS Dynamics for Retrieving Stable Models of Arteries " In Yasuhiro Honda (Ed.), Intravascular Ultrasound (pp. 185–206). Intech.
|
|
|
Debora Gil. (2004). "Geometric Differential Operators for Shape Modelling " (Jordi Saludes i Closa, & Petia Radeva, Eds.). Ph.D. thesis, Ediciones Graficas Rey, Barcelona (Spain).
Abstract: Medical imaging feeds research in many computer vision and image processing fields: image filtering, segmentation, shape recovery, registration, retrieval and pattern matching. Because of their low contrast changes and large variety of artifacts and noise, medical imaging processing techniques relying on an analysis of the geometry of image level sets rather than on intensity values result in more robust treatment. From the starting point of treatment of intravascular images, this PhD thesis ad- dresses the design of differential image operators based on geometric principles for a robust shape modelling and restoration. Among all fields applying shape recovery, we approach filtering and segmentation of image objects. For a successful use in real images, the segmentation process should go through three stages: noise removing, shape modelling and shape recovery. This PhD addresses all three topics, but for the sake of algorithms as automated as possible, techniques for image processing will be designed to satisfy three main principles: a) convergence of the iterative schemes to non-trivial states avoiding image degeneration to a constant image and representing smooth models of the originals; b) smooth asymptotic behav- ior ensuring stabilization of the iterative process; c) fixed parameter values ensuring equal (domain free) performance of the algorithms whatever initial images/shapes. Our geometric approach to the generic equations that model the different processes approached enables defining techniques satisfying all the former requirements. First, we introduce a new curvature-based geometric flow for image filtering achieving a good compromise between noise removing and resemblance to original images. Sec- ond, we describe a new family of diffusion operators that restrict their scope to image level curves and serve to restore smooth closed models from unconnected sets of points. Finally, we design a regularization of snake (distance) maps that ensures its smooth convergence towards any closed shape. Experiments show that performance of the techniques proposed overpasses that of state-of-the-art algorithms.
|
|
|
Debora Gil, F. Javier Sanchez, Gloria Fernandez Esparrach, & Jorge Bernal. (2015). "3D Stable Spatio-temporal Polyp Localization in Colonoscopy Videos " In Computer-Assisted and Robotic Endoscopy. Revised selected papers of Second International Workshop, CARE 2015, Held in Conjunction with MICCAI 2015 (Vol. 9515, pp. 140–152).
Abstract: Computational intelligent systems could reduce polyp miss rate in colonoscopy for colon cancer diagnosis and, thus, increase the efficiency of the procedure. One of the main problems of existing polyp localization methods is a lack of spatio-temporal stability in their response. We propose to explore the response of a given polyp localization across temporal windows in order to select
those image regions presenting the highest stable spatio-temporal response.
Spatio-temporal stability is achieved by extracting 3D watershed regions on the
temporal window. Stability in localization response is statistically determined by analysis of the variance of the output of the localization method inside each 3D region. We have explored the benefits of considering spatio-temporal stability in two different tasks: polyp localization and polyp detection. Experimental results indicate an average improvement of 21:5% in polyp localization and 43:78% in polyp detection.
Keywords: Colonoscopy, Polyp Detection, Polyp Localization, Region Extraction, Watersheds
|
|
|
H. Martin, Jens Fagertun, Sergio Vera, & Debora Gil. (2017). "Medial structure generation for registration of anatomical structures " In Skeletonization, Theory, Methods and Applications (Vol. 11).
|
|