|
Debora Gil, Jordi Gonzalez, & Gemma Sanchez (Eds.). (2007)." Computer Vision: Advances in Research and Development" . 2. Bellaterra (Spain): UAB.
|
|
|
Debora Gil, Petia Radeva, & Fernando Vilariño. (2003). "Anisotropic Contour Completion " In Proceedings of the IEEE International Conference on Image Processing. Barcelona, Spain.
Abstract: In this paper we introduce a novel application of the diffusion tensor for anisotropic image processing. The Anisotropic Contour Completion (ACC) we suggest consists in extending the characteristic function of the open curve by means of a degenerated diffusion tensor that prevents any diffusion in the normal direction. We show that ACC is equivalent to a dilation with a continuous elliptic structural element that takes into account the local orientation of the contours to be closed. Experiments on contours extracted from real images show that ACC produces shapes able to adapt to any curve in an active contour framework. 1.
|
|
|
Enric Marti, Debora Gil, Marc Vivet, & Carme Julia. (2009)." Aprendizaje Basado en Proyectos en la asignatura de Gráficos por Computador en Ingeniería Informática. Balance de cuatro años de experiencia" . Barcelona, Spain.
|
|
|
Debora Gil, Agnes Borras, Manuel Ballester, Francesc Carreras, Ruth Aris, Manuel Vazquez, et al. (2011). "MIOCARDIA: Integrating cardiac function and muscular architecture for a better diagnosis " In Association for Computing Machinery (Ed.), 14th International Symposium on Applied Sciences in Biomedical and Communication Technologies. Barcelona, Spain.
Abstract: Deep understanding of myocardial structure of the heart would unravel crucial knowledge for clinical and medical procedures. The MIOCARDIA project is a multidisciplinary project in cooperation with l'Hospital de la Santa Creu i de Sant Pau, Clinica la Creu Blanca and Barcelona Supercomputing Center. The ultimate goal of this project is defining a computational model of the myocardium. The model takes into account the deep interrelation between the anatomy and the mechanics of the heart. The paper explains the workflow of the MIOCARDIA project. It also introduces a multiresolution reconstruction technique based on DT-MRI streamlining for simplified global myocardial model generation. Our reconstructions can restore the most complex myocardial structures and provides evidences of a global helical organization.
|
|
|
Jaume Garcia, Debora Gil, Francesc Carreras, Sandra Pujades, & R.Leta. (2007). "Modelització 4-Dimensional de la Funció Siatólica del Ventricle Esquerre " In XIX Congrés de la Societat Catalana de Cardiologia de Barcelona (pp. 133–134). Barcelona (Spain).
Abstract: L’evolució tecnològica en el tractament de les imatges mèdiques permet reconstruir, amb el software apropiat, imatges tridimensionals de les estructures cardiovasculars i dotar-les de moviment. Les imatges 4D resultants faciliten l’estudi de la fisiopatologia de la insuficiència cardíaca en base als transtorns de l’activació electromecànica ventricular, el que pot ser d’interès en el procés de selecció de pacients candidats a teràpies de resincronització. Presentem els resultats preliminars de la reconstrucció 4D del ventricle esquerre (VE) a partir de les seqüències de tagging miocàrdic del VE.
|
|
|
Debora Gil. (2004). "Geometric Differential Operators for Shape Modelling " (Jordi Saludes i Closa, & Petia Radeva, Eds.). Ph.D. thesis, Ediciones Graficas Rey, Barcelona (Spain).
Abstract: Medical imaging feeds research in many computer vision and image processing fields: image filtering, segmentation, shape recovery, registration, retrieval and pattern matching. Because of their low contrast changes and large variety of artifacts and noise, medical imaging processing techniques relying on an analysis of the geometry of image level sets rather than on intensity values result in more robust treatment. From the starting point of treatment of intravascular images, this PhD thesis ad- dresses the design of differential image operators based on geometric principles for a robust shape modelling and restoration. Among all fields applying shape recovery, we approach filtering and segmentation of image objects. For a successful use in real images, the segmentation process should go through three stages: noise removing, shape modelling and shape recovery. This PhD addresses all three topics, but for the sake of algorithms as automated as possible, techniques for image processing will be designed to satisfy three main principles: a) convergence of the iterative schemes to non-trivial states avoiding image degeneration to a constant image and representing smooth models of the originals; b) smooth asymptotic behav- ior ensuring stabilization of the iterative process; c) fixed parameter values ensuring equal (domain free) performance of the algorithms whatever initial images/shapes. Our geometric approach to the generic equations that model the different processes approached enables defining techniques satisfying all the former requirements. First, we introduce a new curvature-based geometric flow for image filtering achieving a good compromise between noise removing and resemblance to original images. Sec- ond, we describe a new family of diffusion operators that restrict their scope to image level curves and serve to restore smooth closed models from unconnected sets of points. Finally, we design a regularization of snake (distance) maps that ensures its smooth convergence towards any closed shape. Experiments show that performance of the techniques proposed overpasses that of state-of-the-art algorithms.
|
|
|
Debora Gil, & Petia Radeva. (2004). "Inhibition of False Landmarks " In J. V. et al (Ed.), Recent Advances in Artificial Intelligence Research and Development (pp. 233–244). Barcelona (Spain): IOS Press.
Abstract: We argue that a corner detector should be based on the degree of continuity of the tangent vector to the image level sets, work on the image domain and need no assumptions on neither the image local structure nor the particular geometry of the corner/junction. An operator measuring the degree of differentiability of the projection matrix on the image gradient fulfills the above requirements. Its high sensitivity to changes in vector directions makes it suitable for landmark location in real images prone to need smoothing to reduce the impact of noise. Because using smoothing kernels leads to corner misplacement, we suggest an alternative fake response remover based on the receptive field inhibition of spurious details. The combination of both orientation discontinuity detection and noise inhibition produce our Inhibition Orientation Energy (IOE) landmark locator.
|
|
|
Oriol Rodriguez-Leor, Debora Gil, Eduard Fernandez-Nofrerias, H. Tizon, S. Montserrat, Vicente del Valle, et al. (2007)." Caracterització de la Perfusió Miocàrdica mitjançant anàlisi estadístic de l espectre en l angiografia de contrast" In XIX Congrés de la Societat Catalana de Cardiologia de Barcelona (130). Barcelona (Spain).
Abstract: La valoració de la integritat de la microcirculació coronària aporta informació pronòstica en pacients amb infart agut de miocardi en els que es realitza angioplastia primària. Aquesta valoració és subjectiva i presenta una important variabilitat si no es duta a terme per personal experimentat. Presentem una eina d’anàlisi d’imatge que permet fer una valoració de la microcirculació coronària a partir de seqüències d’angiografia. Hem analitzat les variacions locals en el nivell de gris de la imatge durant la seqüència angiogràfica. Hem identificat els principals fenòmens observats (respiració, batec cardíac, tinció arterial, tinció miocàrdica i soroll radiològic) mitjançant un anàlisi estadístic de l’espectre de Fourier de l’evolució al llarg del temps de la mitja local. Aquest mateix anàlisis permet determinat la influència de cadascun d’ells en la extracció del patró de tinció i selecciona la respiració com el fenomen que més distorsiona el patró de tinció original. Els descriptors proposats s’obtenen fora del rang espectral respiratori. Hem testat la seva capacitat per a detectar els tres fenòmens principals (tinció miocàrdica (MS), tinció arterial (AS) i soroll (NS)) independentment de la respiració. La capacitat de discriminació dels descriptors ha estat valorada mitjançant un mètode de crossvalidation en 30 seqüències d’angiografia. Els descriptors emprats permeten caracteritzar la tinció miocàrdica amb una alta eficiència i fiabilitat. A més no hi ha diferències significatives en l’anàlisi de les seqüències obtingudes amb el pacient respirant amb normalitat o en apnea
|
|
|
Oriol Rodriguez-Leor, Eduard Fernandez-Nofrerias, J. Mauri, Vicente del Valle, Debora Gil, A.Barrios, et al. (2006)." Perfusion ratio: A new tool to objectively assess microcirculation perfusion after primary Percutaneous Coronary Intervention" In World Congress of Cardiology (859). Barcelona (Spain).
|
|
|
Oriol Rodriguez-Leor, J. Mauri, Eduard Fernandez-Nofrerias, Vicente de Valle, E. Garcia, A. Barrios, et al. (2006)." Analysis of the changes in angiography local grey-level values to determine myocardial perfusion" In World Congress of Cardiology (862). Barcelona (Spain).
|
|