toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
  Records Links
Author Joan M. Nuñez edit   pdf
openurl 
  Title Computer vision techniques for characterization of finger joints in X-ray image Type Report
  Year 2011 Publication CVC Technical Report Abbreviated Journal  
  Volume 165 Issue Pages  
  Keywords Rheumatoid arthritis, X-ray, Sharp Van der Heijde, joint characterization, sclerosis detection, bone detection, edge, ridge  
  Abstract Rheumatoid arthritis (RA) is an autoimmune inflammatory type of arthritis which mainly affects hands on its first stages. Though it is a chronic disease and there is no cure for it, treatments require an accurate assessment of illness evolution. Such assessment is based on evaluation of hand X-ray images by using one of the several available semi-quantitative methods. This task requires highly trained medical personnel. That is why the automation of the assessment would allow professionals to save time and effort. Two stages are involved in this task. Firstly, the joint detection, afterwards, the joint characterization. Unlike the little existing previous work, this contribution clearly separates those two stages and sets the foundations of a modular assessment system focusing on the characterization stage. A hand joint dataset is created and an accurate data analysis is achieved in order to identify relevant features. Since the sclerosis and the lower bone were decided to be the most important features, different computer vision techniques were used in order to develop a detector system for both of them. Joint space width measures are provided and their correlation with Sharp-Van der Heijde is verified  
  Address Bellaterra (Barcelona)  
  Corporate Author Computer Vision Center Thesis Master's thesis  
  Publisher Place of Publication Editor Dr. Fernando Vilariño and Dra. Debora Gil  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes (down) MV;IAM; Approved no  
  Call Number IAM @ iam @ Nuñ2011 Serial 1795  
Permanent link to this record
 

 
Author Ole Larsen; Petia Radeva; Enric Marti edit  openurl
  Title Calculating the Bounds on the Optimal Parameters of Elasticity for a Snake Type Report
  Year 1994 Publication Technical Report Abbreviated Journal  
  Volume Issue Pages  
  Keywords  
  Abstract  
  Address Aalborg University  
  Corporate Author Thesis  
  Publisher Aalborg University, Laboratory of image Analysis. Place of Publication Denmark Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Aalborg University, Laboratory of image Analysis. Expedition Conference  
  Notes (down) MILAB;IAM Approved no  
  Call Number IAM @ iam @ LRM1994 Serial 1560  
Permanent link to this record
 

 
Author Petia Radeva; Amir Amini; Jintao Huang; Enric Marti edit   pdf
openurl 
  Title Deformable B-Solids: application for localization and tracking of MRI-SPAMM data Type Report
  Year 1996 Publication CVC Technical Report Abbreviated Journal  
  Volume Issue 8 Pages  
  Keywords  
  Abstract To date, MRI-SPAMM data from different image slices have been analyzed independently. In this paper, we propose an approach for 3D tag localization and tracking of SPAMM data by a novel deformable B-solid. The solid is defined in terms of a 3D tensor product B-spline. The isoparametric curves of the B-spline solid have special importance. These are termed implicit snakes as they deform under image forces from tag lines in different image slices. The localization and tracking of tag lines is performed under constraints of continuity and smoothness of the B-solid. The framework unifies the problems of localization, and displacement fitting and interpolation into the same procedure utilizing B-spline bases for interpolation. To track motion from boundaries and restrict image forces to the myocardium, a volumetric model is employed as a pair of coupled endocardial and epicardial B-spline surfaces. To recover deformations in the LV an energy-minimization problem is posed where both tag and ...  
  Address  
  Corporate Author Thesis  
  Publisher CVC (UAB) Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes (down) MILAB;IAM Approved no  
  Call Number IAM @ iam @ RHM1996 Serial 1631  
Permanent link to this record
 

 
Author Carles Sanchez edit   pdf
openurl 
  Title Tracheal ring detection in bronchoscopy Type Report
  Year 2011 Publication CVC Technical Report Abbreviated Journal  
  Volume 168 Issue Pages  
  Keywords Bronchoscopy, tracheal ring, segmentation  
  Abstract Endoscopy is the process in which a camera is introduced inside a human.
Given that endoscopy provides realistic images (in contrast to other modalities) and allows non-invase minimal intervention procedures (which can aid in diagnosis and surgical interventions), its use has spreaded during last decades.
In this project we will focus on bronchoscopic procedures, during which the camera is introduced through the trachea in order to have a diagnostic of the patient. The diagnostic interventions are focused on: degree of stenosis (reduction in tracheal area), prosthesis or early diagnosis of tumors. In the first case, assessment of the luminal area and the calculation of the diameters of the tracheal rings are required. A main limitation is that all the process is done by hand,
which means that the doctor takes all the measurements and decisions just by looking at the screen. As far as we know there is no computational framework for helping the doctors in the diagnosis.
This project will consist of analysing bronchoscopic videos in order to extract useful information for the diagnostic of the degree of stenosis. In particular we will focus on segmentation of the tracheal rings. As a result of this project several strategies (for detecting tracheal rings) had been implemented in order to compare their performance.
 
  Address  
  Corporate Author Thesis Master's thesis  
  Publisher Place of Publication Editor Debora Gil, F.Javier Sanchez  
  Language english Summary Language english Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes (down) IAM;MV Approved no  
  Call Number IAM @ iam @ San2011 Serial 1841  
Permanent link to this record
 

 
Author Debora Gil; Petia Radeva edit  openurl
  Title Curvature based Distance Maps Type Report
  Year 2003 Publication CVC Technical Report Abbreviated Journal  
  Volume Issue 70 Pages  
  Keywords  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Computer Vision Center Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes (down) IAM;MILAB Approved no  
  Call Number IAM @ iam @ GIR2003a Serial 1534  
Permanent link to this record
 

 
Author Aura Hernandez-Sabate; Debora Gil; Petia Radeva edit   pdf
openurl 
  Title A Deterministic-Statistical Strategy for Adventitia Segmentation in IVUS images Type Report
  Year 2005 Publication CVC Technical Report Abbreviated Journal  
  Volume Issue 89 Pages  
  Keywords  
  Abstract A useful tool for some specific studies in cardiac disease diagnosis is vessel plaque assessment by analysis of IVUS sequences. Manual detection of luminal (inner) and media-adventitia (external) vessel borders is the main activity of physicians in the process of lumen narrowing (plaque) quantification. Difficult definition of vessel border descriptors, as well as, shades, artifacts and blurred signal response due to ultrasound physical properties troubles automated adventitia segmentation. In order to efficiently approach such a complex problem, we propose blending advanced anisotropic filtering operators and statistical classification techniques into a vessel border modelling strategy. Our systematic statistical analysis shows that the reported adventitia detection achieves an accuracy in the range of inter-observer variability regardless of plaque nature, vessel geometry and incomplete vessel borders.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes (down) IAM; MILAB Approved no  
  Call Number IAM @ iam @ HGR2005a Serial 1548  
Permanent link to this record
 

 
Author Antonio Esteban Lansaque edit  openurl
  Title 3D reconstruction and recognition using structured ligth Type Report
  Year 2014 Publication CVC Technical Report Abbreviated Journal  
  Volume 179 Issue Pages  
  Keywords  
  Abstract This work covers the problem of 3D reconstruction, recognition and 6DOF pose estimation. The goal of this project is to reconstruct a 3D scene and to align an object model of the industrial pieces onto the reconstructed scene. The reconstruction algorithm is based on stereo techniques and the recognition algorithm is based on SHOT descriptors computed on a set of uniform keypoints. Correspondences are used to estimate a first 6DOF transformation that maps the model onto the scene and then ICP algorithm is used to refine the transformation. In order to check the effectiveness of the proposed algorithm, several experiments were performed. These experiments were conducted on a lab environment in order to get results under the same conditions in all of them. Although obtained results are not real time results, the proposed algorithm ends up with high rates of object recognition.  
  Address UAB; September 2014  
  Corporate Author Thesis Master's thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes (down) IAM; 600.075 Approved no  
  Call Number Admin @ si @ Est2014 Serial 2578  
Permanent link to this record
 

 
Author Albert Andaluz edit   pdf
openurl 
  Title LV Contour Segmentation in TMR images using Semantic Description of Tissue and Prior Knowledge Correction Type Report
  Year 2009 Publication CVC Technical Report Abbreviated Journal  
  Volume 142 Issue Pages  
  Keywords Active Contour Models; Snakes; Active Shape Models; Deformable Templates; Left Ventricle Segmentation; Generalized Orthogonal Procrustes Analysis; Harmonic Phase Flow; Principal Component Analysis; Tagged Magnetic Resonance  
  Abstract The Diagnosis of Left Ventricle (LV) pathologies is related to regional wall motion analysis. Health indicator scores such as the rotation and the torsion are useful for the diagnose of the Left Ventricle (LV) function. However, this requires proper identification of LV segments. On one hand, manual segmentation is robust, but it is slow and requires medical expertise. On the other hand, the tag pattern in Tagged Magnetic Resonance (TMR) sequences is a problem for the automatic segmentation of the LV boundaries. Consequently, we propose a method based in the classical formulation of parametric Snakes, combined with Active Shape models. Our semantic definition of the LV is tagged tissue that experiences motion in the systolic cycle. This defines two energy potentials for the Snake convergence. Additionally, the mean shape corrects excessive deviation from the anatomical shape. We have validated our approach in 15 healthy volunteers and two short axis cuts. In this way, we have compared the automatic segmentations to manual shapes outlined by medical experts. Also, we have explored the accuracy of clinical scores computed using automatic contours. The results show minor divergence in the approximation and the manual segmentations as well as robust computation of clinical scores in all cases. From this we conclude that the proposed method is a promising support tool for clinical analysis.  
  Address  
  Corporate Author Thesis Master's thesis  
  Publisher Place of Publication Bellaterra 08193, Barcelona, Spain Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes (down) IAM; Approved no  
  Call Number IAM @ iam @ And2009 Serial 1667  
Permanent link to this record
 

 
Author Jaume Garcia edit   pdf
openurl 
  Title Generalized Active Shape Models Applied to Cardiac Function Analysis Type Report
  Year 2004 Publication CVC Technical Report Abbreviated Journal  
  Volume Issue 78 Pages  
  Keywords Cardiac Analysis; Deformable Models; Active Contour Models; Active Shape Models; Tagged MRI; HARP; Contrast Echocardiography.  
  Abstract Medical imaging is very useful in the assessment and treatment of many diseases. To deal with the great amount of data provided by imaging scanners and extract quantitative information that physicians can interpret, many analysis algorithms have been developed. Any process of analysis always consists of a first step of segmenting some particular structure. In medical imaging, structures are not always well defined and suffer from noise artifacts thus, ordinary segmentation methods are not well suited. The ones that seem to give better results are those based on deformable models. Nevertheless, despite their capability of mixing image features together with smoothness constraints that may compensate for image irregularities, these are naturally local methods, i. e., each node of the active contour evolve taking into account information about its neighbors and some other weak constraints about flexibility and smoothness, but not about the global shape that they should find. Due to the fact that structures to be segmented are the same for all cases but with some inter and intra-patient variation, the incorporation of a priori knowledge about shape in the segmentation method will provide robustness to it. Active Shape Models is an algorithm based on the creation of a shape model called Point Distribution Model. It performs a segmentation using only shapes similar than those previously learned from a training set that capture most of the variation presented by the structure. This algorithm works by updating shape nodes along a normal segment which often can be too restrictive. For this reason we propose a generalization of this algorithm that we call Generalized Active Shape Models and fully integrates the a priori knowledge given by the Point Distribution Model with deformable models or any other appropriate segmentation method. Two different applications to cardiac imaging of this generalized method are developed and promising results are shown.  
  Address CVC (UAB)  
  Corporate Author Thesis Master's thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes (down) IAM; Approved no  
  Call Number IAM @ iam @ Gar2004 Serial 1513  
Permanent link to this record
 

 
Author Debora Gil edit  openurl
  Title Regularized Curvature Flow Type Report
  Year 2002 Publication CVC Technical Report Abbreviated Journal  
  Volume Issue 63 Pages  
  Keywords  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Computer Vision Centre Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes (down) IAM; Approved no  
  Call Number IAM @ iam @ Gil2002 Serial 1518  
Permanent link to this record
Select All    Deselect All
 |   | 
Details

Save Citations:
Export Records: