|
Aura Hernandez-Sabate, & Debora Gil. (2012). "The Benefits of IVUS Dynamics for Retrieving Stable Models of Arteries " In Yasuhiro Honda (Ed.), Intravascular Ultrasound (pp. 185–206). Intech.
|
|
|
Aura Hernandez-Sabate. (2009). "Exploring Arterial Dynamics and Structures in IntraVascular Ultrasound Sequences " (Debora Gil, Ed.). Ph.D. thesis, Ediciones Graficas Rey, .
Abstract: Cardiovascular diseases are a leading cause of death in developed countries. Most of them are caused by arterial (specially coronary) diseases, mainly caused by plaque accumulation. Such pathology narrows blood flow (stenosis) and affects artery bio- mechanical elastic properties (atherosclerosis). In the last decades, IntraVascular UltraSound (IVUS) has become a usual imaging technique for the diagnosis and follow up of arterial diseases. IVUS is a catheter-based imaging technique which shows a sequence of cross sections of the artery under study. Inspection of a single image gives information about the percentage of stenosis. Meanwhile, inspection of longitudinal views provides information about artery bio-mechanical properties, which can prevent a fatal outcome of the cardiovascular disease. On one hand, dynamics of arteries (due to heart pumping among others) is a major artifact for exploring tissue bio-mechanical properties. On the other one, manual stenosis measurements require a manual tracing of vessel borders, which is a time-consuming task and might suffer from inter-observer variations. This PhD thesis proposes several image processing tools for exploring vessel dy- namics and structures. We present a physics-based model to extract, analyze and correct vessel in-plane rigid dynamics and to retrieve cardiac phase. Furthermore, we introduce a deterministic-statistical method for automatic vessel borders detection. In particular, we address adventitia layer segmentation. An accurate validation pro- tocol to ensure reliable clinical applicability of the methods is a crucial step in any proposal of an algorithm. In this thesis we take special care in designing a valida- tion protocol for each approach proposed and we contribute to the in vivo dynamics validation with a quantitative and objective score to measure the amount of motion suppressed.
|
|
|
Josep Llados, Jaime Lopez-Krahe, & Enric Marti. (1997). "A system to understand hand-drawn floor plans using subgraph isomorphism and Hough transform " In Machine Vision and Applications (Vol. 10, pp. 150–158).
Abstract: Presently, man-machine interface development is a widespread research activity. A system to understand hand drawn architectural drawings in a CAD environment is presented in this paper. To understand a document, we have to identify its building elements and their structural properties. An attributed graph structure is chosen as a symbolic representation of the input document and the patterns to recognize in it. An inexact subgraph isomorphism procedure using relaxation labeling techniques is performed. In this paper we focus on how to speed up the matching. There is a building element, the walls, characterized by a hatching pattern. Using a straight line Hough transform (SLHT)-based method, we recognize this pattern, characterized by parallel straight lines, and remove from the input graph the edges belonging to this pattern. The isomorphism is then applied to the remainder of the input graph. When all the building elements have been recognized, the document is redrawn, correcting the inaccurate strokes obtained from a hand-drawn input.
Keywords: Line drawings – Hough transform – Graph matching – CAD systems – Graphics recognition
|
|
|
Ole Vilhelm-Larsen, Petia Radeva, & Enric Marti. (1995). "Guidelines for choosing optimal parameters of elasticity for snakes " In Computer Analysis Of Images And Patterns (Vol. 970, pp. 106–113). Lecture Notes in Computer Science.
Abstract: This paper proposes a guidance in the process of choosing and using the parameters of elasticity of a snake in order to obtain a precise segmentation. A new two step procedure is defined based on upper and lower bounds on the parameters. Formulas, by which these bounds can be calculated for real images where parts of the contour may be missing, are presented. Experiments on segmentation of bone structures in X-ray images have verified the usefulness of the new procedure.
|
|
|
Josep Llados, Ernest Valveny, & Enric Marti. (2000)." Symbol Recognition in Document Image Analysis: Methods and Challenges" In Recent Research Developments in Pattern Recognition, Transworld Research Network, (Vol. 1, 151–178.).
|
|
|
Josep Llados, Ernest Valveny, Gemma Sanchez, & Enric Marti. (2002). "Symbol recognition: current advances and perspectives " In Dorothea Blostein and Young- Bin Kwon (Ed.), Graphics Recognition Algorithms And Applications (Vol. 2390, pp. 104–128). Lecture Notes in Computer Science. Springer-Verlag.
Abstract: The recognition of symbols in graphic documents is an intensive research activity in the community of pattern recognition and document analysis. A key issue in the interpretation of maps, engineering drawings, diagrams, etc. is the recognition of domain dependent symbols according to a symbol database. In this work we first review the most outstanding symbol recognition methods from two different points of view: application domains and pattern recognition methods. In the second part of the paper, open and unaddressed problems involved in symbol recognition are described, analyzing their current state of art and discussing future research challenges. Thus, issues such as symbol representation, matching, segmentation, learning, scalability of recognition methods and performance evaluation are addressed in this work. Finally, we discuss the perspectives of symbol recognition concerning to new paradigms such as user interfaces in handheld computers or document database and WWW indexing by graphical content.
|
|
|
Enric Marti, Jordi Regincos, Juan Jose Villanueva, & Jaime Lopez-Krahe. (1994). "Line drawing interpretation as polyhedral objects to man-machine interaction in CAD systems " In Advances in Pattern Recognition and Image Analysis, (pp. 158–169). World Scientific Pub.
|
|
|
Enric Marti, Jordi Vitria, & Alberto Sanfeliu. (1998). "Reconocimiento de Formas y Análisis de Imágenes ". AERFAI.
Abstract: Los sistemas actuales de reconocimiento automático del lenguaje oral se basan en dos etapas básicas de procesado: la parametrización, que extrae la evolución temporal de los parámetros que caracterizan la voz, y el reconocimiento propiamente dicho, que identifica la cadena de palabras de la elocución recibida con ayuda de los modelos que representan el conocimiento adquirido en la etapa de aprendizaje. Tomando como línea divisoria la palabra, dichos modelos son de tipo acústicofonético o gramatical. Los primeros caracterizan las palabras incluidas en el vocabulario de la aplicación o tarea a la que está orientado el sistema de reconocimiento, usando a menudo para ello modelos de unidades de habla de extensión inferior a la palabra, es decir, de unidades subléxicas. Por otro lado, la gramática incluye el conocimiento acerca de las combinaciones permitidas de palabras para formar las frases o su probabilidad. Queda fuera del esquema la denominada comprensión del habla, que utiliza adicionalmente el conocimiento semántico y pragmático para captar el significado de la elocución de entrada al sistema a partir de la cadena (o cadenas alternativas) de palabras que suministra el reconocedor.
|
|
|
David Roche, Debora Gil, & Jesus Giraldo. (2014). "Mathematical modeling of G protein-coupled receptor function: What can we learn from empirical and mechanistic models? " In G Protein-Coupled Receptors – Modeling and Simulation Advances in Experimental Medicine and Biology (Vol. 796, pp. 159–181). Springer Netherlands.
Abstract: Empirical and mechanistic models differ in their approaches to the analysis of pharmacological effect. Whereas the parameters of the former are not physical constants those of the latter embody the nature, often complex, of biology. Empirical models are exclusively used for curve fitting, merely to characterize the shape of the E/[A] curves. Mechanistic models, on the contrary, enable the examination of mechanistic hypotheses by parameter simulation. Regretfully, the many parameters that mechanistic models may include can represent a great difficulty for curve fitting, representing, thus, a challenge for computational method development. In the present study some empirical and mechanistic models are shown and the connections, which may appear in a number of cases between them, are analyzed from the curves they yield. It may be concluded that systematic and careful curve shape analysis can be extremely useful for the understanding of receptor function, ligand classification and drug discovery, thus providing a common language for the communication between pharmacologists and medicinal chemists.
Keywords: β-arrestin; biased agonism; curve fitting; empirical modeling; evolutionary algorithm; functional selectivity; G protein; GPCR; Hill coefficient; intrinsic efficacy; inverse agonism; mathematical modeling; mechanistic modeling; operational model; parameter optimization; receptor dimer; receptor oligomerization; receptor constitutive activity; signal transduction; two-state model
|
|
|
Misael Rosales, Petia Radeva, Oriol Rodriguez, & Debora Gil. (2005). "Suppression of IVUS Image Rotation. A Kinematic Approach " In Monica Andres and Hernandez Petia and Santos A. and R. Frangi (Ed.), Functional Imaging and Modeling of the Heart (Vol. 3504, pp. 889–892). Lecture Notes in Computer Science, 3504. Springer Berlin / Heidelberg.
Abstract: IntraVascular Ultrasound (IVUS) is an exploratory technique used in interventional procedures that shows cross section images of arteries and provides qualitative information about the causes and severity of the arterial lumen narrowing. Cross section analysis as well as visualization of plaque extension in a vessel segment during the catheter imaging pullback are the technique main advantages. However, IVUS sequence exhibits a periodic rotation artifact that makes difficult the longitudinal lesion inspection and hinders any segmentation algorithm. In this paper we propose a new kinematic method to estimate and remove the image rotation of IVUS images sequences. Results on several IVUS sequences show good results and prompt some of the clinical applications to vessel dynamics study, and relation to vessel pathology.
|
|