|
Petia Radeva, Amir Amini, Jintao Huang, & Enric Marti. (1996). Deformable B-Solids: application for localization and tracking of MRI-SPAMM data. CVC (UAB).
Abstract: To date, MRI-SPAMM data from different image slices have been analyzed independently. In this paper, we propose an approach for 3D tag localization and tracking of SPAMM data by a novel deformable B-solid. The solid is defined in terms of a 3D tensor product B-spline. The isoparametric curves of the B-spline solid have special importance. These are termed implicit snakes as they deform under image forces from tag lines in different image slices. The localization and tracking of tag lines is performed under constraints of continuity and smoothness of the B-solid. The framework unifies the problems of localization, and displacement fitting and interpolation into the same procedure utilizing B-spline bases for interpolation. To track motion from boundaries and restrict image forces to the myocardium, a volumetric model is employed as a pair of coupled endocardial and epicardial B-spline surfaces. To recover deformations in the LV an energy-minimization problem is posed where both tag and ...
|
|
|
Petia Radeva, & Enric Marti. (1995). An improved model of snakes for model-based segmentation. In Proceedings of Computer Analysis of Images and Patterns (pp. 515–520).
Abstract: The main advantage of segmentation by snakes consists in its ability to incorporate smoothness constraints on the detected shapes that can occur. Likewise, we propose to model snakes with other properties that reflect the information provided about the object of interest in a different extent. We consider different kinds of snakes, those searching for contours with a certain direction, those preserving an object’s model, those seeking for symmetry, those expanding open, etc. The availability of such a collection of snakes allows not only the more complete use of the knowledge about the segmented object, but also to solve some problems of the existing snakes. Our experiments on segmentation of facial features justify the usefulness of snakes with different properties.
|
|
|
Petia Radeva, Joan Serrat, & Enric Marti. (1995). A snake for model-based segmentation. In Proc. Conf. Fifth Int Computer Vision (pp. 816–821).
Abstract: Despite the promising results of numerous applications, the hitherto proposed snake techniques share some common problems: snake attraction by spurious edge points, snake degeneration (shrinking and attening), convergence and stability of the deformation process, snake initialization and local determination of the parameters of elasticity. We argue here that these problems can be solved only when all the snake aspects are considered. The snakes proposed here implement a new potential eld and external force in order to provide a deformation convergence, attraction by both near and far edges as well as snake behaviour selective according to the edge orientation. Furthermore, we conclude that in the case of model-based seg mentation, the internal force should include structural information about the expected snake shape. Experiments using this kind of snakes for segmenting bones in complex hand radiographs show a signicant improvement.
Keywords: snakes; elastic matching; model-based segmenta tion
|
|
|
Oriol Rodriguez-Leon.A.Carol, H.Tizon, Eduard Fernandez-Nofrerias, Josefina Mauri, Vicente del Valle, Debora Gil, et al. (2005). Model estadístic-determinístic per la segmentació de l adventicia en imatges d ecografía intracoronaria. Rev Societat Catalana Cardiologia, 5, 41.
|
|
|
Oriol Rodriguez-Leon, Josefina Mauri, Eduard Fernandez-Nofrerias, M.Gomez, Antonio Tovar, L.Cano, et al. (2002). Ecografia Intracoronària: Segmentació Automàtica de area de la llum. In XXXVIII Congreso Nacional de la Sociedad Española de Cardiología..
|
|
|
Oriol Rodriguez-Leon, Debora Gil, & Eduard Fernandez-Nofrerias. (2006). Analisis en los cambios en el nivel de gris en las secuencias angiograficas mediante descriptores estadisticos para determinar la perfusion miocardica. REC - Revista Española de Cardiología, 59 Supl 2-166(2), 128.
|
|
|
Oriol Rodriguez-Leon, Josefina Mauri, Eduard Fernandez-Nofrerias, C.Garcia, R.Villuendas, Vicente del Valle, et al. (2003). Reconstruction of a spatio-temporal model of the intima layer from intravascular ultrasound sequences. European Heart Journal, .
|
|
|
Oriol Rodriguez-Leon, Josefina Mauri, Eduard Fernandez-Nofrerias, Antonio Tovar, Vicente del Valle, Aura Hernandez-Sabate, et al. (2004). Utilización de la Estructura de los Campos Vectoriales para la Detección de la Adventicia en Imágenes de Ecografía Intracoronaria. Revista Internacional de Enfermedades Cardiovasculares Revista Española de Cardiología, 57(2), 100.
|
|
|
Misael Rosales, Petia Radeva, Oriol Rodriguez, & Debora Gil. (2005). Suppression of IVUS Image Rotation. A Kinematic Approach. In Monica Andres and Hernandez Petia and Santos A. and R. Frangi (Ed.), Functional Imaging and Modeling of the Heart (Vol. 3504, pp. 889–892). LNCS, 3504. Springer Berlin / Heidelberg.
Abstract: IntraVascular Ultrasound (IVUS) is an exploratory technique used in interventional procedures that shows cross section images of arteries and provides qualitative information about the causes and severity of the arterial lumen narrowing. Cross section analysis as well as visualization of plaque extension in a vessel segment during the catheter imaging pullback are the technique main advantages. However, IVUS sequence exhibits a periodic rotation artifact that makes difficult the longitudinal lesion inspection and hinders any segmentation algorithm. In this paper we propose a new kinematic method to estimate and remove the image rotation of IVUS images sequences. Results on several IVUS sequences show good results and prompt some of the clinical applications to vessel dynamics study, and relation to vessel pathology.
|
|
|
Misael Rosales, Petia Radeva, Oriol Rodriguez-Leon, & Debora Gil. (2009). Modelling of image-catheter motion for 3-D IVUS. MIA - Medical image analysis, 13(1), 91–104.
Abstract: Three-dimensional intravascular ultrasound (IVUS) allows to visualize and obtain volumetric measurements of coronary lesions through an exploration of the cross sections and longitudinal views of arteries. However, the visualization and subsequent morpho-geometric measurements in IVUS longitudinal cuts are subject to distortion caused by periodic image/vessel motion around the IVUS catheter. Usually, to overcome the image motion artifact ECG-gating and image-gated approaches are proposed, leading to slowing the pullback acquisition or disregarding part of IVUS data. In this paper, we argue that the image motion is due to 3-D vessel geometry as well as cardiac dynamics, and propose a dynamic model based on the tracking of an elliptical vessel approximation to recover the rigid transformation and align IVUS images without loosing any IVUS data. We report an extensive validation with synthetic simulated data and in vivo IVUS sequences of 30 patients achieving an average reduction of the image artifact of 97% in synthetic data and 79% in real-data. Our study shows that IVUS alignment improves longitudinal analysis of the IVUS data and is a necessary step towards accurate reconstruction and volumetric measurements of 3-D IVUS.
Keywords: Intravascular ultrasound (IVUS); Motion estimation; Motion decomposition; Fourier
|
|
|
David Rotger, Misael Rosales, Jaume Garcia, Oriol Pujol, Josefina Mauri, & Petia Radeva. (2003). Active Vessel: A New Multimedia Workstation for Intravascular Ultrasound and Angiography Fusion. Computers in Cardiology, 30, 65–68.
Abstract: AcriveVessel is a new multimedia workstation which enables the visualization, acquisition and handling of both image modalities, on- and ofline. It enables DICOM v3.0 decompression and browsing, video acquisition,repmduction and storage for IntraVascular UltraSound (IVUS) and angiograms with their corresponding ECG,automatic catheter segmentation in angiography images (using fast marching algorithm). BSpline models definition for vessel layers on IVUS images sequence and an extensively validated tool to fuse information. This approach defines the correspondence of every IVUS image with its correspondent point in the angiogram and viceversa. The 3 0 reconstruction of the NUS catheterhessel enables real distance measurements as well as threedimensional visualization showing vessel tortuosity in the space.
|
|
|
F. Javier Sanchez, Jordi Vitria, & Enric Marti. (1991). Transformaciones Morfológicas de Polígonos Isotéticos. In Primer Congreso Español de Informática Gráfica..
|
|
|
Gemma Sanchez, Ernest Valveny, Josep Llados, Enric Marti, Oriol Ramos Terrades, N.Lozano, et al. (2003). A system for virtual prototyping of architectural projects. In Proceedings of Fifth IAPR International Workshop on Pattern Recognition (pp. 65–74).
|
|
|
Joan Serrat, & Enric Marti. (1991). Elastic matching using interpolation splines. In IV Spanish Symposium of Pattern Recognition and image Analysis.
|
|
|
Elena Valderrama, Joan Oliver, Josep Maria-Basart, Enric Marti, Petia Radeva, Ricardo Toledo, et al. (2005). Convergencia al EEES de la ingeniería informática. Título de Grado en tecnología (Informática).
Abstract: Elena Valderrama
|
|