toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author J.L.Bruguera; R.Casado; M.Martinez; I.Corral; Enric Marti; L.A.Branda edit  openurl
  Title El apoyo institucional como elemento favorecedor de la coordinación docente: experiencias en diferentes universidades Type Miscellaneous
  Year 2009 Publication Revista Red-U Abbreviated Journal  
  Volume Issue Pages  
  Keywords  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes IAM Approved no  
  Call Number (up) IAM @ iam @ BCM2009 Serial 1490  
Permanent link to this record
 

 
Author Jorge Bernal edit   pdf
openurl 
  Title Use of Projection and Back-projection Methods in Bidimensional Computed Tomography Image Reconstruction Type Report
  Year 2009 Publication CVC Tecnical Report Abbreviated Journal  
  Volume 141 Issue Pages  
  Keywords Projection, Back-projection, CT scan, Euclidean geometry, Radon transform  
  Abstract One of the biggest drawbacks related to the use of CT scanners is the cost (in memory and in time) associated. In this project many methods to simulate their functioning, but in a more feasible way (taking an industrial point of view), will be studied.
The main group of techniques that are being used are the one entitled as ’back-projection’. The concept behind is to simulate the X ray emission in CT scans by lines that cross with the image we want to reconstruct.
In the first part of this document euclidean geometry is used to face the tasks of projec- tion and back-projection. After analysing the results achieved it has been proved that this approach does not lead to a fully perfect reconstruction (and also has some other problems related to running time and memory cost). Because of this in the second part of the document ’Filtered Back-projection’ method is introduced in order to improve the results.
Filtered Back-projection methods rely on mathematical transforms (Fourier, Radon) in order to provide more accurate results that can be obtained in much less time. The main cause of this better results is the use of a filtering process before the back-projection in order to avoid high frequency-caused errors.
As a result of this project two different implementations (one for each approach) had been implemented in order to compare their performance.
 
  Address  
  Corporate Author Computer Vision Center Thesis Master's thesis  
  Publisher Place of Publication Barcelona, Spain Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area 800 Expedition Conference  
  Notes MV; Approved no  
  Call Number (up) IAM @ iam @ Ber2009 Serial 1693  
Permanent link to this record
 

 
Author Joel Barajas; Jaume Garcia; Karla Lizbeth Caballero; Francesc Carreras; Sandra Pujades; Petia Radeva edit   pdf
isbn  openurl
  Title Correction of Misalignment Artifacts Among 2-D Cardiac MR Images in 3-D Space Type Conference Article
  Year 2006 Publication 1st International Wokshop on Computer Vision for Intravascular and Intracardiac Imaging (CVII’06) Abbreviated Journal  
  Volume 3217 Issue Pages 114-121  
  Keywords  
  Abstract Cardiac Magnetic Resonance images offer the opportunity to study the heart in detail. One of the main issues in its modelling is to create an accurate 3-D reconstruction of the left ventricle from 2-D views. A first step to achieve this goal is the correct registration among the different image planes due to patient movements. In this article, we present an accurate method to correct displacement artifacts using the Normalized Mutual Information. Here, the image views are treated as planes in order to diminish the approximation error caused by the association of a certain thickness, and moved simultaneously to avoid any kind of bias in the alignment process. This method has been validated using real and syntectic plane displacements, yielding promising results.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Copenhagen (Denmark) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN 978-3-540-22977-3 Medium  
  Area Expedition Conference  
  Notes IAM;MILAB Approved no  
  Call Number (up) IAM @ iam @ BGC2006 Serial 1485  
Permanent link to this record
 

 
Author Jorge Bernal; F. Javier Sanchez; Fernando Vilariño edit   pdf
url  openurl
  Title Current Challenges on Polyp Detection in Colonoscopy Videos: From Region Segmentation to Region Classification. a Pattern Recognition-based Approach.ased Approach Type Conference Article
  Year 2011 Publication 2nd International Workshop on Medical Image Analysis and Descriptionfor Diagnosis Systems Abbreviated Journal  
  Volume Issue Pages 62-71  
  Keywords Medical Imaging, Colonoscopy, Pattern Recognition, Segmentation, Polyp Detection, Region Description, Machine Learning, Real-time.  
  Abstract In this paper we present our approach on real-time polyp detection in colonoscopy videos. Our method consists of three stages: Image Segmentation, Region Description and Image Classification. Taking into account the constraints of our project, we introduce our segmentation system that is based on the model of appearance of the polyp that we have defined after observing real videos from colonoscopy processes. The output of this stage will ideally be a low number of regions of which one of them should cover the whole polyp region (if there is one in the image). This regions will be described in terms of features and, as a result of a machine learning schema, classified based on the values that they have for the several features that we will use on their description. Although we are still on the early stages of the project, we present some preliminary segmentation results that indicates that we are going in a good direction.  
  Address Rome, Italy  
  Corporate Author Thesis  
  Publisher SciTePress Place of Publication Editor Djemal, Khalifa  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area 800 Expedition Conference MIAD  
  Notes MV;SIAI Approved no  
  Call Number (up) IAM @ iam @ BSV2011a Serial 1695  
Permanent link to this record
 

 
Author Jorge Bernal; F. Javier Sanchez; Fernando Vilariño edit   pdf
url  isbn
openurl 
  Title Depth of Valleys Accumulation Algorithm for Object Detection Type Conference Article
  Year 2011 Publication 14th Congrès Català en Intel·ligencia Artificial Abbreviated Journal  
  Volume 1 Issue 1 Pages 71-80  
  Keywords Object Recognition, Object Region Identification, Image Analysis, Image Processing  
  Abstract This work aims at detecting in which regions the objects in the image are by using information about the intensity of valleys, which appear to surround ob- jects in images where the source of light is in the line of direction than the camera. We present our depth of valleys accumulation method, which consists of two stages: first, the definition of the depth of valleys image which combines the output of a ridges and valleys detector with the morphological gradient to measure how deep is a point inside a valley and second, an algorithm that denotes points of the image as interior to objects those which are inside complete or incomplete boundaries in the depth of valleys image. To evaluate the performance of our method we have tested it on several application domains. Our results on object region identification are promising, specially in the field of polyp detection in colonoscopy videos, and we also show its applicability in different areas.  
  Address Lleida  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN 978-1-60750-841-0 Medium  
  Area 800 Expedition Conference CCIA  
  Notes MV;SIAI Approved no  
  Call Number (up) IAM @ iam @ BSV2011b Serial 1699  
Permanent link to this record
 

 
Author Jorge Bernal; F. Javier Sanchez; Fernando Vilariño edit   pdf
doi  isbn
openurl 
  Title A Region Segmentation Method for Colonoscopy Images Using a Model of Polyp Appearance Type Conference Article
  Year 2011 Publication 5th Iberian Conference on Pattern Recognition and Image Analysis Abbreviated Journal  
  Volume 6669 Issue Pages 134-143     
  Keywords Colonoscopy, Polyp Detection, Region Merging, Region Segmentation.  
  Abstract This work aims at the segmentation of colonoscopy images into a minimum number of informative regions. Our method performs in a way such, if a polyp is present in the image, it will be exclusively and totally contained in a single region. This result can be used in later stages to classify regions as polyp-containing candidates. The output of the algorithm also defines which regions can be considered as non-informative. The algorithm starts with a high number of initial regions and merges them taking into account the model of polyp appearance obtained from available data. The results show that our segmentations of polyp regions are more accurate than state-of-the-art methods.  
  Address Las Palmas de Gran Canaria, June 2011  
  Corporate Author SpringerLink Thesis  
  Publisher Place of Publication Editor Vitrià, Jordi and Sanches, João and Hernández, Mario  
  Language Summary Language Original Title  
  Series Editor Series Title Lecture Notes in Computer Science Abbreviated Series Title LNCS  
  Series Volume Series Issue Edition  
  ISSN ISBN 978-3-642-21256-7 Medium  
  Area 800 Expedition Conference IbPRIA  
  Notes MV;SIAI Approved no  
  Call Number (up) IAM @ iam @ BSV2011c Serial 1696  
Permanent link to this record
 

 
Author Jorge Bernal; F. Javier Sanchez; Fernando Vilariño edit   pdf
url  doi
openurl 
  Title Integration of Valley Orientation Distribution for Polyp Region Identification in Colonoscopy Type Conference Article
  Year 2011 Publication In MICCAI 2011 Workshop on Computational and Clinical Applications in Abdominal Imaging Abbreviated Journal  
  Volume 6668 Issue Pages 76-83  
  Keywords  
  Abstract This work presents a region descriptor based on the integration of the information that the depth of valleys image provides. The depth of valleys image is based on the presence of intensity valleys around polyps due to the image acquisition. Our proposed method consists of defining, for each point, a series of radial sectors around it and then accumulates the maxima of the depth of valleys image only if the orientation of the intensity valley coincides with the orientation of the sector above. We apply our descriptor to a prior segmentation of the images and we present promising results on polyp detection, outperforming other approaches that also integrate depth of valleys information.  
  Address Toronto, Canada  
  Corporate Author Thesis  
  Publisher Springer Link Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Lecture Notes in Computer Science Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area 800 Expedition Conference ABI  
  Notes MV;SIAI Approved no  
  Call Number (up) IAM @ iam @ BSV2011d Serial 1698  
Permanent link to this record
 

 
Author Jorge Bernal; Fernando Vilariño; F. Javier Sanchez edit   pdf
url  doi
isbn  openurl
  Title Towards Intelligent Systems for Colonoscopy Type Book Chapter
  Year 2011 Publication Colonoscopy Abbreviated Journal  
  Volume 1 Issue Pages 257-282  
  Keywords  
  Abstract In this chapter we present tools that can be used to build intelligent systems for colonoscopy.
The idea is, by using methods based on computer vision and artificial intelligence, add significant value to the colonoscopy procedure. Intelligent systems are being used to assist in other medical interventions
 
  Address  
  Corporate Author Thesis  
  Publisher Intech Place of Publication Editor Paul Miskovitz  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN 978-953-307-568-6 Medium  
  Area 800 Expedition Conference  
  Notes MV;SIAI Approved no  
  Call Number (up) IAM @ iam @ BVS2011 Serial 1697  
Permanent link to this record
 

 
Author Francesc Carreras; Jaume Garcia; Debora Gil; Sandra Pujadas; Chi ho Lion; R.Suarez-Arias; R.Leta; Xavier Alomar; Manuel Ballester; Guillem Pons-Llados edit  url
doi  openurl
  Title Left ventricular torsion and longitudinal shortening: two fundamental components of myocardial mechanics assessed by tagged cine-MRI in normal subjects Type Journal Article
  Year 2012 Publication International Journal of Cardiovascular Imaging Abbreviated Journal IJCI  
  Volume 28 Issue 2 Pages 273-284  
  Keywords Magnetic resonance imaging (MRI); Tagging MRI; Cardiac mechanics; Ventricular torsion  
  Abstract Cardiac magnetic resonance imaging (Cardiac MRI) has become a gold standard diagnostic technique for the assessment of cardiac mechanics, allowing the non-invasive calculation of left ventric- ular long axis longitudinal shortening (LVLS) and absolute myocardial torsion (AMT) between basal and apical left ventricular slices, a movement directly related to the helicoidal anatomic disposition of the myocardial fibers. The aim of this study is to determine AMT and LVLS behaviour and normal values from a group of healthy subjects. A group of 21 healthy volunteers (15 males) (age: 23–55 y.o., mean:30.7 ± 7.5) were prospectively included in an obser- vational study by Cardiac MRI. Left ventricular rotation (degrees) was calculated by custom-made software (Harmonic Phase Flow) in consecutive LV short axis planes tagged cine-MRI sequences. AMT was determined from the difference between basal and apical planes LV rotations. LVLS (%) was determined from the LV longitudinal and horizontal axis cine-MRI images. All the 21 cases studied were interpretable, although in three cases the value of the LV apical rotation could not be determined. The mean rotation of the basal and apical planes at end-systole were -3.71° ± 0.84° and 6.73° ± 1.69° (n:18) respectively, resulting in a LV mean AMT of 10.48° ± 1.63° (n:18). End-systolic mean LVLS was 19.07 ± 2.71%. Cardiac MRI allows for the calculation of AMT and LVLS, fundamental functional components of the ventricular twist mechanics conditioned, in turn, by the anatomical helical layout of the myocardial fibers. These values provide complementary information about systolic ventricular function in relation to the traditional parameters used in daily practice.  
  Address  
  Corporate Author Thesis  
  Publisher Springer Netherlands Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1569-5794 ISBN Medium  
  Area Expedition Conference  
  Notes IAM; Approved no  
  Call Number (up) IAM @ iam @ CGG2012 Serial 1496  
Permanent link to this record
 

 
Author Cristina Cañero; Petia Radeva; Oriol Pujol; Ricardo Toledo; Debora Gil; J. Saludes; Juan J. Villanueva; B. Garcia del Blanco; J. Mauri; E. Fernandez-Nofrerias; J.A. Gomez-Hospital; E. Iraculis; J. Comin; C. Quiles; F. Jara; A. Cequier; E. Esplugas edit   pdf
openurl 
  Title Optimal Stent Implantation: Three-dimensional Evaluation of the Mutual Position of Stent and Vessel via Intracoronary Ecography Type Conference Article
  Year 1999 Publication Proceedings of International Conference on Computer in Cardiology (CIC´99) Abbreviated Journal  
  Volume Issue Pages  
  Keywords  
  Abstract We present a new automatic technique to visualize and quantify the mutual position between the stent and the vessel wall by considering their three-dimensional reconstruction. Two deformable generalized cylinders adapt to the image features in all IVUS planes corresponding to the vessel wall and the stent in order to reconstruct the boundaries of the stent and the vessel in space. The image features that characterize the stent and the vessel wall are determined in terms of edge and ridge image detectors taking into account the gray level of the image pixels. We show that the 30 reconstruction by deformable cylinders is accurate and robust due to the spatial data coherence in the considered volumetric IVUS image. The main clinic utility of the stent and vessel reconstruction by deformable’ cylinders consists of its possibility to visualize and to assess the optimal stent introduction.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes MILAB; RV; IAM; ADAS; HuPBA Approved no  
  Call Number (up) IAM @ iam @ CRP1999a Serial 1491  
Permanent link to this record
 

 
Author Cristina Cañero; Petia Radeva; Oriol Pujol; Ricardo Toledo; Debora Gil; J. Saludes; Juan J. Villanueva; B. Garcia del Blanco; J. Mauri; Eduard Fernandez-Nofrerias; J.A. Gomez-Hospital; E. Iraculis; J. Comin; C. Quiles; F. Jara; A. Cequier; E.Esplugas edit   pdf
openurl 
  Title Three-dimensional reconstruction and quantification of the coronary tree using intravascular ultrasound images Type Conference Article
  Year 1999 Publication Proceedings of International Conference on Computer in Cardiology (CIC´99) Abbreviated Journal  
  Volume Issue Pages  
  Keywords  
  Abstract In this paper we propose a new Computer Vision technique to reconstruct the vascular wall in space using a deformable model-based technique and compounding methods, based in biplane angiography and intravascular ultrasound data jicsion. It is also proposed a generalpurpose three-dimensional guided interpolation method. The three dimensional centerline of the vessel is reconstructed from geometrically corrected biplane angiographies using automatic segmentation methods and snakes. The IVUS image planes are located in the threedimensional space and correctly oriented. A led interpolation method based in B-SurJaces and snakes isused to fill the gaps among image planes  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference CINC99  
  Notes MILAB;RV;IAM;ADAS;HuPBA Approved no  
  Call Number (up) IAM @ iam @ CRP1999b Serial 1492  
Permanent link to this record
 

 
Author G.Estape; Enric Marti edit  openurl
  Title L’ús d’aplicacions de visualització 3D com a eina d’aprenenetatge en activitats formatives dirigides i autònomes: el cas del programa Bluestar Type Miscellaneous
  Year 2008 Publication V Jornades d’Innovació Docent UAB Abbreviated Journal  
  Volume Issue Pages  
  Keywords  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes IAM Approved no  
  Call Number (up) IAM @ iam @ ESM2008 Serial 1495  
Permanent link to this record
 

 
Author Debora Gil; Jaume Garcia; Ruth Aris; Guillaume Houzeaux; Manuel Vazquez edit   pdf
openurl 
  Title A Riemmanian approach to cardiac fiber architecture modelling Type Conference Article
  Year 2009 Publication 1st International Conference on Mathematical & Computational Biomedical Engineering Abbreviated Journal  
  Volume Issue Pages 59-62  
  Keywords cardiac fiber architecture; diffusion tensor magnetic resonance imaging; differential (Rie- mannian) geometry.  
  Abstract There is general consensus that myocardial fiber architecture should be modelled in order to fully understand the electromechanical properties of the Left Ventricle (LV). Diffusion Tensor magnetic resonance Imaging (DTI) is the reference image modality for rapid measurement of fiber orientations by means of the tensor principal eigenvectors. In this work, we present a mathematical framework for across subject comparison of the local geometry of the LV anatomy including the fiber architecture from the statistical analysis of DTI studies. We use concepts of differential geometry for defining a parametric domain suitable for statistical analysis of a low number of samples. We use Riemannian metrics to define a consistent computation of DTI principal eigenvector modes of variation. Our framework has been applied to build an atlas of the LV fiber architecture from 7 DTI normal canine hearts.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Swansea (UK) Editor Nithiarasu, R.L.R.V.L.  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference CMBE  
  Notes IAM Approved no  
  Call Number (up) IAM @ iam @ FGA2009 Serial 1520  
Permanent link to this record
 

 
Author Miquel Ferrer; Dimosthenis Karatzas; Ernest Valveny; I. Bardaji; Horst Bunke edit  openurl
  Title A Generic Framework for Median Graph Computation based on a Recursive Embedding Approach Type Journal Article
  Year 2011 Publication Computer Vision and Image Understanding Abbreviated Journal CVIU  
  Volume 115 Issue 7 Pages 919-928  
  Keywords Median Graph, Graph Embedding, Graph Matching, Structural Pattern Recognition  
  Abstract The median graph has been shown to be a good choice to obtain a represen- tative of a set of graphs. However, its computation is a complex problem. Recently, graph embedding into vector spaces has been proposed to obtain approximations of the median graph. The problem with such an approach is how to go from a point in the vector space back to a graph in the graph space. The main contribution of this paper is the generalization of this previ- ous method, proposing a generic recursive procedure that permits to recover the graph corresponding to a point in the vector space, introducing only the amount of approximation inherent to the use of graph matching algorithms. In order to evaluate the proposed method, we compare it with the set me- dian and with the other state-of-the-art embedding-based methods for the median graph computation. The experiments are carried out using four dif- ferent databases (one semi-artificial and three containing real-world data). Results show that with the proposed approach we can obtain better medi- ans, in terms of the sum of distances to the training graphs, than with the previous existing methods.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes DAG Approved no  
  Call Number (up) IAM @ iam @ FKV2011 Serial 1831  
Permanent link to this record
 

 
Author Paula Fritzsche; C.Roig; Ana Ripoll; Emilio Luque; Aura Hernandez-Sabate edit   pdf
doi  openurl
  Title A Performance Prediction Methodology for Data-dependent Parallel Applications Type Conference Article
  Year 2006 Publication Proceedings of the IEEE International Conference on Cluster Computing Abbreviated Journal  
  Volume Issue Pages 1-8  
  Keywords  
  Abstract The increase in the use of parallel distributed architectures in order to solve large-scale scientific problems has generated the need for performance prediction for both deterministic applications and non-deterministic applications. In particular, the performance prediction of data dependent programs is an extremely challenging problem because for a specific issue the input datasets may cause different execution times. Generally, a parallel application is characterized as a collection of tasks and their interrelations. If the application is time-critical it is not enough to work with only one value per task, and consequently knowledge of the distribution of task execution times is crucial. The development of a new prediction methodology to estimate the performance of data-dependent parallel applications is the primary target of this study. This approach makes it possible to evaluate the parallel performance of an application without the need of implementation. A real data-dependent arterial structure detection application model is used to apply the methodology proposed. The predicted times obtained using the new methodology for genuine datasets are compared with predicted times that arise from using only one execution value per task. Finally, the experimental study shows that the new methodology generates more precise predictions.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes IAM Approved no  
  Call Number (up) IAM @ iam @ FRR2006 Serial 1497  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: