|
Shiqi Yang, Yaxing Wang, Kai Wang, Shangling Jui, & Joost Van de Weijer. (2022). Local Prediction Aggregation: A Frustratingly Easy Source-free Domain Adaptation Method.
Abstract: We propose a simple but effective source-free domain adaptation (SFDA) method. Treating SFDA as an unsupervised clustering problem and following the intuition that local neighbors in feature space should have more similar predictions than other features, we propose to optimize an objective of prediction consistency. This objective encourages local neighborhood features in feature space to have similar predictions while features farther away in feature space have dissimilar predictions, leading to efficient feature clustering and cluster assignment simultaneously. For efficient training, we seek to optimize an upper-bound of the objective resulting in two simple terms. Furthermore, we relate popular existing methods in domain adaptation, source-free domain adaptation and contrastive learning via the perspective of discriminability and diversity. The experimental results prove the superiority of our method, and our method can be adopted as a simple but strong baseline for future research in SFDA. Our method can be also adapted to source-free open-set and partial-set DA which further shows the generalization ability of our method. Code is available in this https URL.
|
|
|
Shiqi Yang, Yaxing Wang, Kai Wang, Shangling Jui, & Joost Van de Weijer. (2022). One Ring to Bring Them All: Towards Open-Set Recognition under Domain Shift.
Abstract: In this paper, we investigate model adaptation under domain and category shift, where the final goal is to achieve
(SF-UNDA), which addresses the situation where there exist both domain and category shifts between source and target domains. Under the SF-UNDA setting, the model cannot access source data anymore during target adaptation, which aims to address data privacy concerns. We propose a novel training scheme to learn a (
+1)-way classifier to predict the
source classes and the unknown class, where samples of only known source categories are available for training. Furthermore, for target adaptation, we simply adopt a weighted entropy minimization to adapt the source pretrained model to the unlabeled target domain without source data. In experiments, we show:
After source training, the resulting source model can get excellent performance for
;
After target adaptation, our method surpasses current UNDA approaches which demand source data during adaptation. The versatility to several different tasks strongly proves the efficacy and generalization ability of our method.
When augmented with a closed-set domain adaptation approach during target adaptation, our source-free method further outperforms the current state-of-the-art UNDA method by 2.5%, 7.2% and 13% on Office-31, Office-Home and VisDA respectively.
|
|
|
Shiqi Yang, Yaxing Wang, Luis Herranz, Shangling Jui, & Joost Van de Weijer. (2023). Casting a BAIT for offline and online source-free domain adaptation. CVIU - Computer Vision and Image Understanding, 234, 103747.
Abstract: We address the source-free domain adaptation (SFDA) problem, where only the source model is available during adaptation to the target domain. We consider two settings: the offline setting where all target data can be visited multiple times (epochs) to arrive at a prediction for each target sample, and the online setting where the target data needs to be directly classified upon arrival. Inspired by diverse classifier based domain adaptation methods, in this paper we introduce a second classifier, but with another classifier head fixed. When adapting to the target domain, the additional classifier initialized from source classifier is expected to find misclassified features. Next, when updating the feature extractor, those features will be pushed towards the right side of the source decision boundary, thus achieving source-free domain adaptation. Experimental results show that the proposed method achieves competitive results for offline SFDA on several benchmark datasets compared with existing DA and SFDA methods, and our method surpasses by a large margin other SFDA methods under online source-free domain adaptation setting.
|
|
|
Shun Yao, Fei Yang, Yongmei Cheng, & Mikhail Mozerov. (2021). 3D Shapes Local Geometry Codes Learning with SDF. In International Conference on Computer Vision Workshops (pp. 2110–2117).
Abstract: A signed distance function (SDF) as the 3D shape description is one of the most effective approaches to represent 3D geometry for rendering and reconstruction. Our work is inspired by the state-of-the-art method DeepSDF [17] that learns and analyzes the 3D shape as the iso-surface of its shell and this method has shown promising results especially in the 3D shape reconstruction and compression domain. In this paper, we consider the degeneration problem of reconstruction coming from the capacity decrease of the DeepSDF model, which approximates the SDF with a neural network and a single latent code. We propose Local Geometry Code Learning (LGCL), a model that improves the original DeepSDF results by learning from a local shape geometry of the full 3D shape. We add an extra graph neural network to split the single transmittable latent code into a set of local latent codes distributed on the 3D shape. Mentioned latent codes are used to approximate the SDF in their local regions, which will alleviate the complexity of the approximation compared to the original DeepSDF. Furthermore, we introduce a new geometric loss function to facilitate the training of these local latent codes. Note that other local shape adjusting methods use the 3D voxel representation, which in turn is a problem highly difficult to solve or even is insolvable. In contrast, our architecture is based on graph processing implicitly and performs the learning regression process directly in the latent code space, thus make the proposed architecture more flexible and also simple for realization. Our experiments on 3D shape reconstruction demonstrate that our LGCL method can keep more details with a significantly smaller size of the SDF decoder and outperforms considerably the original DeepSDF method under the most important quantitative metrics.
|
|
|
Silvia Sanchez. (2000). Estudio de viabilidad para la inspeccion de cinturones de seguridad en color.
|
|
|
Silvio Giancola, Anthony Cioppa, Adrien Deliege, Floriane Magera, Vladimir Somers, Le Kang, et al. (2022). SoccerNet 2022 Challenges Results. In 5th International ACM Workshop on Multimedia Content Analysis in Sports (pp. 75–86).
Abstract: The SoccerNet 2022 challenges were the second annual video understanding challenges organized by the SoccerNet team. In 2022, the challenges were composed of 6 vision-based tasks: (1) action spotting, focusing on retrieving action timestamps in long untrimmed videos, (2) replay grounding, focusing on retrieving the live moment of an action shown in a replay, (3) pitch localization, focusing on detecting line and goal part elements, (4) camera calibration, dedicated to retrieving the intrinsic and extrinsic camera parameters, (5) player re-identification, focusing on retrieving the same players across multiple views, and (6) multiple object tracking, focusing on tracking players and the ball through unedited video streams. Compared to last year's challenges, tasks (1-2) had their evaluation metrics redefined to consider tighter temporal accuracies, and tasks (3-6) were novel, including their underlying data and annotations. More information on the tasks, challenges and leaderboards are available on this https URL. Baselines and development kits are available on this https URL.
|
|
|
Simeon Petkov, Adriana Romero, Xavier Carrillo, Petia Radeva, & Carlo Gatta. (2012). Robust and accurate diaphragm border detection in cardiac X-Ray angiographies. In Statistical Atlases And Computational Models Of The Heart: Imaging and Modelling Challenges (Vol. 7746, pp. 225–234). LNCS.
Abstract: Workshop STACOM, dins del MICCAI
X-ray angiography is the most common imaging modality employed in the diagnosis of coronary diseases prior to or during a catheter-based intervention. The analysis of the patient X-Ray sequence can provide useful information about the degree of arterial stenosis, the myocardial perfusion and other clinical parameters. If the sequence has been acquired to evaluate the perfusion grade, the opacity due to the diaphragm could potentially hinder any kind of visual inspection and make more difficult a computer aided measurements. In this paper we propose an accurate and robust method to automatically identify the diaphragm border in each frame. Quantitative evaluation on a set of 11 sequences shows that the proposed algorithm outperforms previous methods.
|
|
|
Simeon Petkov, Xavier Carrillo, Petia Radeva, & Carlo Gatta. (2014). Diaphragm border detection in coronary X-ray angiographies: New method and applications. CMIG - Computerized Medical Imaging and Graphics, 38(4), 296–305.
Abstract: X-ray angiography is widely used in cardiac disease diagnosis during or prior to intravascular interventions. The diaphragm motion and the heart beating induce gray-level changes, which are one of the main obstacles in quantitative analysis of myocardial perfusion. In this paper we focus on detecting the diaphragm border in both single images or whole X-ray angiography sequences. We show that the proposed method outperforms state of the art approaches. We extend a previous publicly available data set, adding new ground truth data. We also compose another set of more challenging images, thus having two separate data sets of increasing difficulty. Finally, we show three applications of our method: (1) a strategy to reduce false positives in vessel enhanced images; (2) a digital diaphragm removal algorithm; (3) an improvement in Myocardial Blush Grade semi-automatic estimation.
|
|
|
Simon Jégou, Michal Drozdzal, David Vazquez, Adriana Romero, & Yoshua Bengio. (2017). The One Hundred Layers Tiramisu: Fully Convolutional DenseNets for Semantic Segmentation. In IEEE Conference on Computer Vision and Pattern Recognition Workshops.
Abstract: State-of-the-art approaches for semantic image segmentation are built on Convolutional Neural Networks (CNNs). The typical segmentation architecture is composed of (a) a downsampling path responsible for extracting coarse semantic features, followed by (b) an upsampling path trained to recover the input image resolution at the output of the model and, optionally, (c) a post-processing module (e.g. Conditional Random Fields) to refine the model predictions.
Recently, a new CNN architecture, Densely Connected Convolutional Networks (DenseNets), has shown excellent results on image classification tasks. The idea of DenseNets is based on the observation that if each layer is directly connected to every other layer in a feed-forward fashion then the network will be more accurate and easier to train.
In this paper, we extend DenseNets to deal with the problem of semantic segmentation. We achieve state-of-the-art results on urban scene benchmark datasets such as CamVid and Gatech, without any further post-processing module nor pretraining. Moreover, due to smart construction of the model, our approach has much less parameters than currently published best entries for these datasets.
Keywords: Semantic Segmentation
|
|
|
Simone Balocco, Carlo Gatta, Francesco Ciompi, A. Wahle, Petia Radeva, S. Carlier, et al. (2014). Standardized evaluation methodology and reference database for evaluating IVUS image segmentation. CMIG - Computerized Medical Imaging and Graphics, 38(2), 70–90.
Abstract: This paper describes an evaluation framework that allows a standardized and quantitative comparison of IVUS lumen and media segmentation algorithms. This framework has been introduced at the MICCAI 2011 Computing and Visualization for (Intra)Vascular Imaging (CVII) workshop, comparing the results of eight teams that participated.
We describe the available data-base comprising of multi-center, multi-vendor and multi-frequency IVUS datasets, their acquisition, the creation of the reference standard and the evaluation measures. The approaches address segmentation of the lumen, the media, or both borders; semi- or fully-automatic operation; and 2-D vs. 3-D methodology. Three performance measures for quantitative analysis have
been proposed. The results of the evaluation indicate that segmentation of the vessel lumen and media is possible with an accuracy that is comparable to manual annotation when semi-automatic methods are used, as well as encouraging results can be obtained also in case of fully-automatic segmentation. The analysis performed in this paper also highlights the challenges in IVUS segmentation that remains to be
solved.
Keywords: IVUS (intravascular ultrasound); Evaluation framework; Algorithm comparison; Image segmentation
|
|
|
Simone Balocco, Carlo Gatta, Francesco Ciompi, Oriol Pujol, Xavier Carrillo, J. Mauri, et al. (2011). Combining Growcut and Temporal Correlation for IVUS Lumen Segmentation. In Jordi Vitria, Joao Miguel Raposo, & Mario Hernandez (Eds.), 5th Iberian Conference on Pattern Recognition and Image Analysis (Vol. 6669, pp. 556–563). LNCS. Berlin: Springer Berlin Heidelberg.
Abstract: The assessment of arterial luminal area, performed by IVUS analysis, is a clinical index used to evaluate the degree of coronary artery disease. In this paper we propose a novel approach to automatically segment the vessel lumen, which combines model-based temporal information extracted from successive frames of the sequence, with spatial classification using the Growcut algorithm. The performance of the method is evaluated by an in vivo experiment on 300 IVUS frames. The automatic and manual segmentation performances in general vessel and stent frames are comparable. The average segmentation error in vessel, stent and bifurcation frames are 0.17±0.08 mm, 0.18±0.07 mm and 0.31±0.12 mm respectively.
|
|
|
Simone Balocco, Carlo Gatta, Marina Alberti, Xavier Carrillo, Juan Rigla, & Petia Radeva. (2012). Relation between plaque type, plaque thickness, blood shear stress and plaque stress in coronary arteries assessed by X-ray Angiography and Intravascular Ultrasound. MEDPHYS - Medical Physics, 39(12), 7430–7445.
Abstract: PMID 23231293
PURPOSE:
Atheromatic plaque progression is affected, among others phenomena, by biomechanical, biochemical, and physiological factors. In this paper, the authors introduce a novel framework able to provide both morphological (vessel radius, plaque thickness, and type) and biomechanical (wall shear stress and Von Mises stress) indices of coronary arteries.
METHODS:
First, the approach reconstructs the three-dimensional morphology of the vessel from intravascular ultrasound (IVUS) and Angiographic sequences, requiring minimal user interaction. Then, a computational pipeline allows to automatically assess fluid-dynamic and mechanical indices. Ten coronary arteries are analyzed illustrating the capabilities of the tool and confirming previous technical and clinical observations.
RESULTS:
The relations between the arterial indices obtained by IVUS measurement and simulations have been quantitatively analyzed along the whole surface of the artery, extending the analysis of the coronary arteries shown in previous state of the art studies. Additionally, for the first time in the literature, the framework allows the computation of the membrane stresses using a simplified mechanical model of the arterial wall.
CONCLUSIONS:
Circumferentially (within a given frame), statistical analysis shows an inverse relation between the wall shear stress and the plaque thickness. At the global level (comparing a frame within the entire vessel), it is observed that heavy plaque accumulations are in general calcified and are located in the areas of the vessel having high wall shear stress. Finally, in their experiments the inverse proportionality between fluid and structural stresses is observed.
|
|
|
Simone Balocco, Carlo Gatta, Oriol Pujol, J. Mauri, & Petia Radeva. (2010). SRBF: Speckle Reducing Bilateral Filtering. UMB - Ultrasound in Medicine and Biology, 36(8), 1353–1363.
Abstract: Speckle noise negatively affects medical ultrasound image shape interpretation and boundary detection. Speckle removal filters are widely used to selectively remove speckle noise without destroying important image features to enhance object boundaries. In this article, a fully automatic bilateral filter tailored to ultrasound images is proposed. The edge preservation property is obtained by embedding noise statistics in the filter framework. Consequently, the filter is able to tackle the multiplicative behavior modulating the smoothing strength with respect to local statistics. The in silico experiments clearly showed that the speckle reducing bilateral filter (SRBF) has superior performances to most of the state of the art filtering methods. The filter is tested on 50 in vivo US images and its influence on a segmentation task is quantified. The results using SRBF filtered data sets show a superior performance to using oriented anisotropic diffusion filtered images. This improvement is due to the adaptive support of SRBF and the embedded noise statistics, yielding a more homogeneous smoothing. SRBF results in a fully automatic, fast and flexible algorithm potentially suitable in wide ranges of speckle noise sizes, for different medical applications (IVUS, B-mode, 3-D matrix array US).
|
|
|
Simone Balocco, Carlo Gatta, Xavier Carrillo, J. Mauri, & Petia Radeva. (2011). Plaque Type, Plaque Burden and Wall Shear Stress Relation in Coronary Arteries Assessed by X-ray Angiography and Intravascular Ultrasound: a Qualitative Study. In 14th International Symposium on Applied Sciences in Biomedical and Communication Technologies.
Abstract: In this paper, we present a complete framework that automatically provides fluid-dynamic and plaque analysis from IVUS and Angiographic sequences. Such framework is used to analyze, in three coronary arteries, the relation between wall shear stress with type and amount of plaque. Preliminary qualitative results show an inverse relation between the wall shear stress and the plaque burden, which is confirmed by the fact that the plaque growth is higher on the wall having concave curvature. Regarding the plaque type it was observed that regions having low shear stress are predominantly fibro-lipidic while the heavy calcifications are in general located in areas of the vessel having high WSS.
|
|
|
Simone Balocco, Francesco Ciompi, Juan Rigla, Xavier Carrillo, J. Mauri, & Petia Radeva. (2017). Intra-Coronary Stent localization In Intravascular Ultrasound Sequences, A Preliminary Study. In International workshop on Computing and Visualization for Intravascular Imaging and Computer Assisted Stenting (CVII-STENT). LNCS.
Abstract: An intraluminal coronary stent is a metal scaold deployed in a stenotic artery during Percutaneous Coronary Intervention (PCI).
Intravascular Ultrasound (IVUS) is a catheter-based imaging technique generally used for assessing the correct placement of the stent. All the approaches proposed so far for the stent analysis only focused on the struts detection, while this paper proposes a novel approach to detect the boundaries and the position of the stent along the pullback.
The pipeline of the method requires the identication of the stable frames
of the sequence and the reliable detection of stent struts. Using this data,
a measure of likelihood for a frame to contain a stent is computed. Then,
a robust binary representation of the presence of the stent in the pullback
is obtained applying an iterative and multi-scale approximation of the signal to symbols using the SAX algorithm. Results obtained comparing the automatic results versus the manual annotation of two observers on 80 IVUS in-vivo sequences shows that the method approaches the inter-observer variability scores.
|
|