Ana Garcia Rodriguez, Yael Tudela, Henry Cordova, S. Carballal, I. Ordas, L. Moreira, et al. (2022). First in Vivo Computer-Aided Diagnosis of Colorectal Polyps using White Light Endoscopy. END - Endoscopy, 54.
|
Victor M. Campello, Carlos Martin-Isla, Cristian Izquierdo, Andrea Guala, Jose F. Rodriguez Palomares, David Vilades, et al. (2022). Minimising multi-centre radiomics variability through image normalisation: a pilot study. ScR - Scientific Reports, 12(1), 12532.
Abstract: Radiomics is an emerging technique for the quantification of imaging data that has recently shown great promise for deeper phenotyping of cardiovascular disease. Thus far, the technique has been mostly applied in single-centre studies. However, one of the main difficulties in multi-centre imaging studies is the inherent variability of image characteristics due to centre differences. In this paper, a comprehensive analysis of radiomics variability under several image- and feature-based normalisation techniques was conducted using a multi-centre cardiovascular magnetic resonance dataset. 218 subjects divided into healthy (n = 112) and hypertrophic cardiomyopathy (n = 106, HCM) groups from five different centres were considered. First and second order texture radiomic features were extracted from three regions of interest, namely the left and right ventricular cavities and the left ventricular myocardium. Two methods were used to assess features’ variability. First, feature distributions were compared across centres to obtain a distribution similarity index. Second, two classification tasks were proposed to assess: (1) the amount of centre-related information encoded in normalised features (centre identification) and (2) the generalisation ability for a classification model when trained on these features (healthy versus HCM classification). The results showed that the feature-based harmonisation technique ComBat is able to remove the variability introduced by centre information from radiomic features, at the expense of slightly degrading classification performance. Piecewise linear histogram matching normalisation gave features with greater generalisation ability for classification ( balanced accuracy in between 0.78 ± 0.08 and 0.79 ± 0.09). Models trained with features from images without normalisation showed the worst performance overall ( balanced accuracy in between 0.45 ± 0.28 and 0.60 ± 0.22). In conclusion, centre-related information removal did not imply good generalisation ability for classification.
|
Saad Minhas, Zeba Khanam, Shoaib Ehsan, Klaus McDonald Maier, & Aura Hernandez-Sabate. (2022). Weather Classification by Utilizing Synthetic Data. SENS - Sensors, 22(9), 3193.
Abstract: Weather prediction from real-world images can be termed a complex task when targeting classification using neural networks. Moreover, the number of images throughout the available datasets can contain a huge amount of variance when comparing locations with the weather those images are representing. In this article, the capabilities of a custom built driver simulator are explored specifically to simulate a wide range of weather conditions. Moreover, the performance of a new synthetic dataset generated by the above simulator is also assessed. The results indicate that the use of synthetic datasets in conjunction with real-world datasets can increase the training efficiency of the CNNs by as much as 74%. The article paves a way forward to tackle the persistent problem of bias in vision-based datasets.
Keywords: Weather classification; synthetic data; dataset; autonomous car; computer vision; advanced driver assistance systems; deep learning; intelligent transportation systems
|
Xavier Soria, Gonzalo Pomboza-Junez, & Angel Sappa. (2022). LDC: Lightweight Dense CNN for Edge Detection. ACCESS - IEEE Access, 10, 68281–68290.
Abstract: This paper presents a Lightweight Dense Convolutional (LDC) neural network for edge detection. The proposed model is an adaptation of two state-of-the-art approaches, but it requires less than 4% of parameters in comparison with these approaches. The proposed architecture generates thin edge maps and reaches the highest score (i.e., ODS) when compared with lightweight models (models with less than 1 million parameters), and reaches a similar performance when compare with heavy architectures (models with about 35 million parameters). Both quantitative and qualitative results and comparisons with state-of-the-art models, using different edge detection datasets, are provided. The proposed LDC does not use pre-trained weights and requires straightforward hyper-parameter settings. The source code is released at https://github.com/xavysp/LDC
|
Sonia Baeza, Debora Gil, I.Garcia Olive, M.Salcedo, J.Deportos, Carles Sanchez, et al. (2022). A novel intelligent radiomic analysis of perfusion SPECT/CT images to optimize pulmonary embolism diagnosis in COVID-19 patients. EJNMMI-PHYS - EJNMMI Physics, 9(1, Article 84), 1–17.
Abstract: Background: COVID-19 infection, especially in cases with pneumonia, is associated with a high rate of pulmonary embolism (PE). In patients with contraindications for CT pulmonary angiography (CTPA) or non-diagnostic CTPA, perfusion single-photon emission computed tomography/computed tomography (Q-SPECT/CT) is a diagnostic alternative. The goal of this study is to develop a radiomic diagnostic system to detect PE based only on the analysis of Q-SPECT/CT scans.
Methods: This radiomic diagnostic system is based on a local analysis of Q-SPECT/CT volumes that includes both CT and Q-SPECT values for each volume point. We present a combined approach that uses radiomic features extracted from each scan as input into a fully connected classifcation neural network that optimizes a weighted crossentropy loss trained to discriminate between three diferent types of image patterns (pixel sample level): healthy lungs (control group), PE and pneumonia. Four types of models using diferent confguration of parameters were tested.
Results: The proposed radiomic diagnostic system was trained on 20 patients (4,927 sets of samples of three types of image patterns) and validated in a group of 39 patients (4,410 sets of samples of three types of image patterns). In the training group, COVID-19 infection corresponded to 45% of the cases and 51.28% in the test group. In the test group, the best model for determining diferent types of image patterns with PE presented a sensitivity, specifcity, positive predictive value and negative predictive value of 75.1%, 98.2%, 88.9% and 95.4%, respectively. The best model for detecting
pneumonia presented a sensitivity, specifcity, positive predictive value and negative predictive value of 94.1%, 93.6%, 85.2% and 97.6%, respectively. The area under the curve (AUC) was 0.92 for PE and 0.91 for pneumonia. When the results obtained at the pixel sample level are aggregated into regions of interest, the sensitivity of the PE increases to 85%, and all metrics improve for pneumonia.
Conclusion: This radiomic diagnostic system was able to identify the diferent lung imaging patterns and is a frst step toward a comprehensive intelligent radiomic system to optimize the diagnosis of PE by Q-SPECT/CT.
|
Diego Velazquez, Pau Rodriguez, Josep M. Gonfaus, Xavier Roca, & Jordi Gonzalez. (2022). A Closer Look at Embedding Propagation for Manifold Smoothing. JMLR - Journal of Machine Learning Research, 23(252), 1–27.
Abstract: Supervised training of neural networks requires a large amount of manually annotated data and the resulting networks tend to be sensitive to out-of-distribution (OOD) data.
Self- and semi-supervised training schemes reduce the amount of annotated data required during the training process. However, OOD generalization remains a major challenge for most methods. Strategies that promote smoother decision boundaries play an important role in out-of-distribution generalization. For example, embedding propagation (EP) for manifold smoothing has recently shown to considerably improve the OOD performance for few-shot classification. EP achieves smoother class manifolds by building a graph from sample embeddings and propagating information through the nodes in an unsupervised manner. In this work, we extend the original EP paper providing additional evidence and experiments showing that it attains smoother class embedding manifolds and improves results in settings beyond few-shot classification. Concretely, we show that EP improves the robustness of neural networks against multiple adversarial attacks as well as semi- and
self-supervised learning performance.
Keywords: Regularization; emi-supervised learning; self-supervised learning; adversarial robustness; few-shot classification
|
Robert Benavente, & Maria Vanrell. (2004). Fuzzy Colour Naming Based on Sigmoid Membership Functions..
|
Xavier Otazu, & Maria Vanrell. (2004). Building Perceived Colour Images..
|
Francesc Tous, Maria Vanrell, & Ramon Baldrich. (2004). Exploring Colour Constancy Solutions..
|
Dani Rowe, Jordi Gonzalez, Ivan Huerta, & Juan J. Villanueva. (2007). On Reasoning over Tracking Events. In 15th Scandinavian Conference on Image Analysis (Vol. 4522, 502–511). LNCS.
|
Ole Larsen, Petia Radeva, & Enric Marti. (1994). Calculating the Bounds on the Optimal Parameters of Elasticity for a Snake. Denmark: Aalborg University, Laboratory of image Analysis.
|
Bogdan Raducanu, & Jordi Vitria. (2006). Aprendiendo a Aprender: de Maquinas Listas a Maquinas Inteligentes.
|
Maria Oliver, Gloria Haro, Mariella Dimiccoli, Baptiste Mazin, & Coloma Ballester. (2016). A computational model of amodal completion. In SIAM Conference on Imaging Science.
Abstract: This paper presents a computational model to recover the most likely interpretation of the 3D scene structure from a planar image, where some objects may occlude others. The estimated scene interpretation is obtained by integrating some global and local cues and provides both the complete disoccluded objects that form the scene and their ordering according to depth. Our method first computes several distal scenes which are compatible with the proximal planar image. To compute these different hypothesized scenes, we propose a perceptually inspired object disocclusion method, which works by minimizing the Euler's elastica as well as by incorporating the relatability of partially occluded contours and the convexity of the disoccluded objects. Then, to estimate the preferred scene we rely on a Bayesian model and define probabilities taking into account the global complexity of the objects in the hypothesized scenes as well as the effort of bringing these objects in their relative position in the planar image, which is also measured by an Euler's elastica-based quantity. The model is illustrated with numerical experiments on, both, synthetic and real images showing the ability of our model to reconstruct the occluded objects and the preferred perceptual order among them. We also present results on images of the Berkeley dataset with provided figure-ground ground-truth labeling.
|
German Ros, Angel Sappa, Daniel Ponsa, & Antonio Lopez. (2012). Visual SLAM for Driverless Cars: A Brief Survey. In IEEE Workshop on Navigation, Perception, Accurate Positioning and Mapping for Intelligent Vehicles.
|
Naveen Onkarappa, & Angel Sappa. (2012). An Empirical Study on Optical Flow Accuracy Depending on Vehicle Speed. In IEEE Intelligent Vehicles Symposium (pp. 1138–1143). IEEE Xplore.
Abstract: Driver assistance and safety systems are getting attention nowadays towards automatic navigation and safety. Optical flow as a motion estimation technique has got major roll in making these systems a reality. Towards this, in the current paper, the suitability of polar representation for optical flow estimation in such systems is demonstrated. Furthermore, the influence of individual regularization terms on the accuracy of optical flow on image sequences of different speeds is empirically evaluated. Also a new synthetic dataset of image sequences with different speeds is generated along with the ground-truth optical flow.
|