Santiago Segui, Michal Drozdzal, Ekaterina Zaytseva, Fernando Azpiroz, Petia Radeva, & Jordi Vitria. (2014). Detection of wrinkle frames in endoluminal videos using betweenness centrality measures for images. TITB - IEEE Transactions on Information Technology in Biomedicine, 18(6), 1831–1838.
Abstract: Intestinal contractions are one of the most important events to diagnose motility pathologies of the small intestine. When visualized by wireless capsule endoscopy (WCE), the sequence of frames that represents a contraction is characterized by a clear wrinkle structure in the central frames that corresponds to the folding of the intestinal wall. In this paper we present a new method to robustly detect wrinkle frames in full WCE videos by using a new mid-level image descriptor that is based on a centrality measure proposed for graphs. We present an extended validation, carried out in a very large database, that shows that the proposed method achieves state of the art performance for this task.
Keywords: Wireless Capsule Endoscopy; Small Bowel Motility Dysfunction; Contraction Detection; Structured Prediction; Betweenness Centrality
|
|
|
Simeon Petkov, Xavier Carrillo, Petia Radeva, & Carlo Gatta. (2014). Diaphragm border detection in coronary X-ray angiographies: New method and applications. CMIG - Computerized Medical Imaging and Graphics, 38(4), 296–305.
Abstract: X-ray angiography is widely used in cardiac disease diagnosis during or prior to intravascular interventions. The diaphragm motion and the heart beating induce gray-level changes, which are one of the main obstacles in quantitative analysis of myocardial perfusion. In this paper we focus on detecting the diaphragm border in both single images or whole X-ray angiography sequences. We show that the proposed method outperforms state of the art approaches. We extend a previous publicly available data set, adding new ground truth data. We also compose another set of more challenging images, thus having two separate data sets of increasing difficulty. Finally, we show three applications of our method: (1) a strategy to reduce false positives in vessel enhanced images; (2) a digital diaphragm removal algorithm; (3) an improvement in Myocardial Blush Grade semi-automatic estimation.
|
|
|
M. Gomez, J. Mauri, E. Fernandez-Nofrerias, Oriol Rodriguez-Leor, Carme Julia, Oriol Pujol, et al. (2002). Diferenciacion de las estructuras del vaso coronario mediante el procesamiento de imagenes y el analisis de las diferentes texturas a partir de la ecografia intracoronaria. XXXVIII Congreso Nacional de la Sociedad Española de Cardiologia.
|
|
|
Oriol Pujol, Petia Radeva, & Jordi Vitria. (2006). Discriminant ECOC: A Heuristic Method for Application Dependent Design of Error Correcting Output Codes. IEEE Transactions on Pattern Analysis and Machine Intelligence, 28(6): 1007–1012.
|
|
|
Xose M. Pardo, Petia Radeva, & D. Cabello. (2003). Discriminant Snakes for 3D Reconstruction of Anatomical Organs. Medical Image Analysis, 7(3): 293–310 (IF: 4.442).
|
|