2002 |
|
M.Gomez and 6 others. 2002. Reconstrucción de un modelo espacio-temporal de la luz del vaso a partir de secuencias de ecografía intracoronaria. XXXVIII Congreso Nacional de la Sociedad Española de Cardiología..
|
|
|
Oriol Rodriguez-Leon and 10 others. 2002. Ecografia Intracoronària: Segmentació Automàtica de area de la llum. XXXVIII Congreso Nacional de la Sociedad Española de Cardiología..
|
|
2001 |
|
Felipe Lumbreras and 7 others. 2001. Visual Inspection of Safety Belts. International Conference on Quality Control by Artificial Vision.526–531.
|
|
2000 |
|
Josefina Mauri and 14 others. 2000. Avaluació del Conjunt Stent/Artèria mitjançant ecografia intracoronària: lentorn informàtic. Congrés de la Societat Catalana de Cardiologia..
|
|
|
Josefina Mauri and 14 others. 2000. Moviment del vas en l anàlisi d imatges d ecografia intracoronària: un model matemàtic. Congrés de la Societat Catalana de Cardiologia..
|
|
1999 |
|
Cristina Cañero and 16 others. 1999. Optimal Stent Implantation: Three-dimensional Evaluation of the Mutual Position of Stent and Vessel via Intracoronary Ecography. Proceedings of International Conference on Computer in Cardiology (CIC´99).
Abstract: We present a new automatic technique to visualize and quantify the mutual position between the stent and the vessel wall by considering their three-dimensional reconstruction. Two deformable generalized cylinders adapt to the image features in all IVUS planes corresponding to the vessel wall and the stent in order to reconstruct the boundaries of the stent and the vessel in space. The image features that characterize the stent and the vessel wall are determined in terms of edge and ridge image detectors taking into account the gray level of the image pixels. We show that the 30 reconstruction by deformable cylinders is accurate and robust due to the spatial data coherence in the considered volumetric IVUS image. The main clinic utility of the stent and vessel reconstruction by deformable’ cylinders consists of its possibility to visualize and to assess the optimal stent introduction.
|
|
|
Cristina Cañero and 16 others. 1999. Three-dimensional reconstruction and quantification of the coronary tree using intravascular ultrasound images. Proceedings of International Conference on Computer in Cardiology (CIC´99).
Abstract: In this paper we propose a new Computer Vision technique to reconstruct the vascular wall in space using a deformable model-based technique and compounding methods, based in biplane angiography and intravascular ultrasound data jicsion. It is also proposed a generalpurpose three-dimensional guided interpolation method. The three dimensional centerline of the vessel is reconstructed from geometrically corrected biplane angiographies using automatic segmentation methods and snakes. The IVUS image planes are located in the threedimensional space and correctly oriented. A led interpolation method based in B-SurJaces and snakes isused to fill the gaps among image planes
|
|
1995 |
|
Petia Radeva, Joan Serrat and Enric Marti. 1995. A snake for model-based segmentation. Proc. Conf. Fifth Int Computer Vision.816–821.
Abstract: Despite the promising results of numerous applications, the hitherto proposed snake techniques share some common problems: snake attraction by spurious edge points, snake degeneration (shrinking and attening), convergence and stability of the deformation process, snake initialization and local determination of the parameters of elasticity. We argue here that these problems can be solved only when all the snake aspects are considered. The snakes proposed here implement a new potential eld and external force in order to provide a deformation convergence, attraction by both near and far edges as well as snake behaviour selective according to the edge orientation. Furthermore, we conclude that in the case of model-based seg mentation, the internal force should include structural information about the expected snake shape. Experiments using this kind of snakes for segmenting bones in complex hand radiographs show a signicant improvement.
Keywords: snakes; elastic matching; model-based segmenta tion
|
|
1993 |
|
M.J. Yzuel, J. Pladellorens, Joan Serrat and A. Dupuy. 1993. Application restauration and edge detection techniques in the calculation of left ventricular volumes. Optics in Medicine, Biology and Environmental Research : Selected contributions to the first International Conference on Optics within Life Sciences (OWLS I). Elsevier, 374–375.
|
|
|
Petia Radeva and Joan Serrat. 1993. Rubber Snake: Implementation on Signed Distance Potential. Vision Conference.187–194.
|
|