|
Pau Cano, Debora Gil, & Eva Musulen. (2023)." Towards automatic detection of helicobacter pylori in histological samples of gastric tissue" In IEEE International Symposium on Biomedical Imaging.
|
|
|
Guillermo Torres, Debora Gil, Antonio Rosell, Sonia Baeza, & Carles Sanchez. (2023)." A radiomic biopsy for virtual histology of pulmonary nodules" In IEEE International Symposium on Biomedical Imaging.
|
|
|
Jaume Garcia, Debora Gil, Francesc Carreras, Sandra Pujades, R.Leta, Xavier Alomar, et al. (2008). "Patrons de Normalitat Regional per la Valoració de la Funció del Ventricle Esquerre " In XX Congrés de la Societat Catalana de Cardiologia (60). Barcelona.
Abstract: Les malalties cardiovasculars afecten les propietats contràctils de la banda ventricular i provoquen una variació de la funció del Ventricle Esquerre (VE) . Només els indicadors locals (strains, la deformació del teixit) són capaços de detectar anomalies en territoris específics del VE . Patrons de normalitat regionals d’aquests paràmetres serien d’utilitat a l’hora de valorar-ne la funció .
Presentem un Domini Paramètric Normalitzat (DPN) que permet comparar dades de diferents pacients i definir Patrons de Normalitat Regional (PNR)
|
|
|
Jaume Garcia, Debora Gil, Francesc Carreras, Sandra Pujades, R.Leta, Xavier Alomar, et al. (2008). "Un Model 3D del Ventricle Esquerre Integrant Anatomia i Funcionalitat " In XX Congrés de la Societat Catalana de Cardiologia, Actes del Congres (122). Barcelona.
Abstract: Els canvis en la dinàmica del Ventricle Esquerre (VE) reflecteixen la majoria de malalties cardiovasculars . Els avenços en imatge mèdica han impulsat la recerca en models i simulacions de la dinàmica 3D del VE . La majoria dels models existents sols consideren l’anatomia externa del VE i no permeten una avaluació de l’acoblament electromecànic . Donat que la mecànica d’un muscle depèn de la orientació de les seves fibres, un model realista hauria d’incloure la disposició espacial de la banda ventricular helicoidal (BVH) .
Proposem desenvolupar un model del VE adaptat a cada pacient que integri, per primer cop, l’anatomia de la banda ventricular, l’anatomia externa del VE i la seva funcionalitat, per a una millor determinació del patró d’activació electromecànica
|
|
|
Ferran Poveda, Debora Gil, Albert Andaluz, & Enric Marti. (2011). "Multiscale Tractography for Representing Heart Muscular Architecture " In In MICCAI 2011 Workshop on Computational Diffusion MRI.
Abstract: Deep understanding of myocardial structure of the heart would unravel crucial knowledge for clinical and medical procedures. Although the muscular architecture of the heart has been debated by countless researchers, the controversy is still alive. Diffusion Tensor MRI, DT-MRI, is a unique imaging technique for computational validation of the muscular structure of the heart. By the complex arrangement of myocites, existing techniques can not provide comprehensive descriptions of the global muscular architecture. In this paper we introduce a multiresolution reconstruction technique based on DT-MRI streamlining for simplified global myocardial model generation. Our reconstructions can restore the most complex myocardial structures and indicate a global helical organization
|
|
|
Patricia Marquez, Debora Gil, & Aura Hernandez-Sabate. (2011). "A Confidence Measure for Assessing Optical Flow Accuracy in the Absence of Ground Truth " In IEEE International Conference on Computer Vision – Workshops (pp. 2042–2049). Barcelona (Spain): IEEE.
Abstract: Optical flow is a valuable tool for motion analysis in autonomous navigation systems. A reliable application requires determining the accuracy of the computed optical flow. This is a main challenge given the absence of ground truth in real world sequences. This paper introduces a measure of optical flow accuracy for Lucas-Kanade based flows in terms of the numerical stability of the data-term. We call this measure optical flow condition number. A statistical analysis over ground-truth data show a good statistical correlation between the condition number and optical flow error. Experiments on driving sequences illustrate its potential for autonomous navigation systems.
Keywords: IEEE International Conference on Computer Vision – Workshops
|
|
|
Debora Gil, Agnes Borras, Manuel Ballester, Francesc Carreras, Ruth Aris, Manuel Vazquez, et al. (2011). "MIOCARDIA: Integrating cardiac function and muscular architecture for a better diagnosis " In Association for Computing Machinery (Ed.), 14th International Symposium on Applied Sciences in Biomedical and Communication Technologies. Barcelona, Spain.
Abstract: Deep understanding of myocardial structure of the heart would unravel crucial knowledge for clinical and medical procedures. The MIOCARDIA project is a multidisciplinary project in cooperation with l'Hospital de la Santa Creu i de Sant Pau, Clinica la Creu Blanca and Barcelona Supercomputing Center. The ultimate goal of this project is defining a computational model of the myocardium. The model takes into account the deep interrelation between the anatomy and the mechanics of the heart. The paper explains the workflow of the MIOCARDIA project. It also introduces a multiresolution reconstruction technique based on DT-MRI streamlining for simplified global myocardial model generation. Our reconstructions can restore the most complex myocardial structures and provides evidences of a global helical organization.
|
|
|
David Roche, Debora Gil, & Jesus Giraldo. (2012). "Assessing agonist efficacy in an uncertain Em world " In A. Christopoulus and M. Bouvier (Ed.), 40th Keystone Symposia on mollecular and celular biology (79). Keystone Symposia.
Abstract: The operational model of agonism has been widely used for the analysis of agonist action since its formulation in 1983. The model includes the Em parameter, which is defined as the maximum response of the system. The methods for Em estimation provide Em values not significantly higher than the maximum responses achieved by full agonists. However, it has been found that that some classes of compounds as, for instance, superagonists and positive allosteric modulators can increase the full agonist maximum response, implying upper limits for Em and thereby posing doubts on the validity of Em estimates. Because of the correlation between Em and operational efficacy, τ, wrong Em estimates will yield wrong τ estimates.
In this presentation, the operational model of agonism and various methods for the simulation of allosteric modulation will be analyzed. Alternatives for curve fitting will be presented and discussed.
|
|