|
Records |
Links |
|
Author |
David Rotger; Misael Rosales; Jaume Garcia; Oriol Pujol ; Josefina Mauri; Petia Radeva |
|
|
Title |
Active Vessel: A New Multimedia Workstation for Intravascular Ultrasound and Angiography Fusion |
Type |
Journal Article |
|
Year |
2003 |
Publication |
Computers in Cardiology |
Abbreviated Journal |
|
|
|
Volume |
30 |
Issue |
|
Pages |
65-68 |
|
|
Keywords |
|
|
|
Abstract |
AcriveVessel is a new multimedia workstation which enables the visualization, acquisition and handling of both image modalities, on- and ofline. It enables DICOM v3.0 decompression and browsing, video acquisition,repmduction and storage for IntraVascular UltraSound (IVUS) and angiograms with their corresponding ECG,automatic catheter segmentation in angiography images (using fast marching algorithm). BSpline models definition for vessel layers on IVUS images sequence and an extensively validated tool to fuse information. This approach defines the correspondence of every IVUS image with its correspondent point in the angiogram and viceversa. The 3 0 reconstruction of the NUS catheterhessel enables real distance measurements as well as threedimensional visualization showing vessel tortuosity in the space. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB;HuPBA |
Approved |
no |
|
|
Call Number |
IAM @ iam @ RRG2003 |
Serial |
1647 |
|
Permanent link to this record |
|
|
|
|
Author |
David Rotger; Petia Radeva; N. Bruining |
|
|
Title |
Automatic Detection of Bioabsorbable Coronary Stents in IVUS Images using a Cascade of Classifiers |
Type |
Journal Article |
|
Year |
2010 |
Publication |
IEEE Transactions on Information Technology in Biomedicine |
Abbreviated Journal |
TITB |
|
|
Volume |
14 |
Issue |
2 |
Pages |
535 – 537 |
|
|
Keywords |
|
|
|
Abstract |
Bioabsorbable drug-eluting coronary stents present a very promising improvement to the common metallic ones solving some of the most important problems of stent implantation: the late restenosis. These stents made of poly-L-lactic acid cause a very subtle acoustic shadow (compared to the metallic ones) making difficult the automatic detection and measurements in images. In this paper, we propose a novel approach based on a cascade of GentleBoost classifiers to detect the stent struts using structural features to code the information of the different subregions of the struts. A stochastic gradient descent method is applied to optimize the overall performance of the detector. Validation results of struts detection are very encouraging with an average F-measure of 81%. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MILAB |
Approved |
no |
|
|
Call Number |
BCNPCL @ bcnpcl @ RRB2010 |
Serial |
1287 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Aura Hernandez-Sabate; Oriol Rodriguez; Josepa Mauri; Petia Radeva |
|
|
Title |
Statistical Strategy for Anisotropic Adventitia Modelling in IVUS |
Type |
Journal Article |
|
Year |
2006 |
Publication |
IEEE Transactions on Medical Imaging |
Abbreviated Journal |
|
|
|
Volume |
25 |
Issue |
6 |
Pages |
768-778 |
|
|
Keywords |
Corners; T-junctions; Wavelets |
|
|
Abstract |
Vessel plaque assessment by analysis of intravascular ultrasound sequences is a useful tool for cardiac disease diagnosis and intervention. Manual detection of luminal (inner) and mediaadventitia (external) vessel borders is the main activity of physicians in the process of lumen narrowing (plaque) quantification. Difficult definition of vessel border descriptors, as well as, shades, artifacts, and blurred signal response due to ultrasound physical properties trouble automated adventitia segmentation. In order to efficiently approach such a complex problem, we propose blending advanced anisotropic filtering operators and statistical classification techniques into a vessel border modelling strategy. Our systematic statistical analysis shows that the reported adventitia detection achieves an accuracy in the range of interobserver variability regardless of plaque nature, vessel geometry, and incomplete vessel borders. Index Terms–-Anisotropic processing, intravascular ultrasound (IVUS), vessel border segmentation, vessel structure classification. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GHR2006 |
Serial |
1525 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Oriol Rodriguez-Leon; Petia Radeva; Josepa Mauri |
|
|
Title |
Myocardial Perfusion Characterization From Contrast Angiography Spectral Distribution |
Type |
Journal Article |
|
Year |
2008 |
Publication |
IEEE Transactions on Medical Imaging |
Abbreviated Journal |
|
|
|
Volume |
27 |
Issue |
5 |
Pages |
641-649 |
|
|
Keywords |
Contrast angiography; myocardial perfusion; spectral analysis. |
|
|
Abstract |
Despite recovering a normal coronary flow after acute myocardial infarction, percutaneous coronary intervention does not guarantee a proper perfusion (irrigation) of the infarcted area. This damage in microcirculation integrity may detrimentally affect the patient survival. Visual assessment of the myocardium opacification in contrast angiography serves to define a subjective score of the microcirculation integrity myocardial blush analysis (MBA). Although MBA correlates with patient prognosis its visual assessment is a very difficult task that requires of a highly expertise training in order to achieve a good intraobserver and interobserver agreement. In this paper, we provide objective descriptors of the myocardium staining pattern by analyzing the spectrum of the image local statistics. The descriptors proposed discriminate among the different phenomena observed in the angiographic sequence and allow defining an objective score of the myocardial perfusion. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GRR2008 |
Serial |
1541 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Petia Radeva |
|
|
Title |
A Regularized Curvature Flow Designed for a Selective Shape Restoration |
Type |
Journal Article |
|
Year |
2004 |
Publication |
IEEE Transactions on Image Processing |
Abbreviated Journal |
|
|
|
Volume |
13 |
Issue |
|
Pages |
1444–1458 |
|
|
Keywords |
Geometric flows, nonlinear filtering, shape recovery. |
|
|
Abstract |
Among all filtering techniques, those based exclu- sively on image level sets (geometric flows) have proven to be the less sensitive to the nature of noise and the most contrast preserving. A common feature to existent curvature flows is that they penalize high curvature, regardless of the curve regularity. This constitutes a major drawback since curvature extreme values are standard descriptors of the contour geometry. We argue that an operator designed with shape recovery purposes should include a term penalizing irregularity in the curvature rather than its magnitude. To this purpose, we present a novel geometric flow that includes a function that measures the degree of local irregularity present in the curve. A main advantage is that it achieves non-trivial steady states representing a smooth model of level curves in a noisy image. Performance of our approach is compared to classical filtering techniques in terms of quality in the restored image/shape and asymptotic behavior. We empirically prove that our approach is the technique that achieves the best compromise between image quality and evolution stabilization. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
BCNPCL @ bcnpcl @ GiR2004b |
Serial |
491 |
|
Permanent link to this record |