toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
  Records Links
Author (up) Carlo Gatta; Oriol Pujol; O. Rodriguez-Leor; J. M. Ferre; Petia Radeva edit  doi
openurl 
  Title Fast Rigid Registration of Vascular Structures in IVUS Sequences Type Journal Article
  Year 2009 Publication IEEE Transactions on Information Technology in Biomedicine Abbreviated Journal  
  Volume 13 Issue 6 Pages 106-1011  
  Keywords  
  Abstract Intravascular ultrasound (IVUS) technology permits visualization of high-resolution images of internal vascular structures. IVUS is a unique image-guiding tool to display longitudinal view of the vessels, and estimate the length and size of vascular structures with the goal of accurate diagnosis. Unfortunately, due to pulsatile contraction and expansion of the heart, the captured images are affected by different motion artifacts that make visual inspection difficult. In this paper, we propose an efficient algorithm that aligns vascular structures and strongly reduces the saw-shaped oscillation, simplifying the inspection of longitudinal cuts; it reduces the motion artifacts caused by the displacement of the catheter in the short-axis plane and the catheter rotation due to vessel tortuosity. The algorithm prototype aligns 3.16 frames/s and clearly outperforms state-of-the-art methods with similar computational cost. The speed of the algorithm is crucial since it allows to inspect the corrected sequence during patient intervention. Moreover, we improved an indirect methodology for IVUS rigid registration algorithm evaluation.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1089-7771 ISBN Medium  
  Area Expedition Conference  
  Notes MILAB;HuPBA Approved no  
  Call Number BCNPCL @ bcnpcl @ GPL2009 Serial 1250  
Permanent link to this record
 

 
Author (up) Carolina Malagelada; F.De Lorio; Santiago Segui; S. Mendez; Michal Drozdzal; Jordi Vitria; Petia Radeva; J.Santos; Anna Accarino; Juan R. Malagelada; Fernando Azpiroz edit   pdf
doi  openurl
  Title Functional gut disorders or disordered gut function? Small bowel dysmotility evidenced by an original technique Type Journal Article
  Year 2012 Publication Neurogastroenterology & Motility Abbreviated Journal NEUMOT  
  Volume 24 Issue 3 Pages 223-230  
  Keywords capsule endoscopy;computer vision analysis;machine learning technique;small bowel motility  
  Abstract JCR Impact Factor 2010: 3.349
Background This study aimed to determine the proportion of cases with abnormal intestinal motility among patients with functional bowel disorders. To this end, we applied an original method, previously developed in our laboratory, for analysis of endoluminal images obtained by capsule endoscopy. This novel technology is based on computer vision and machine learning techniques.
 Methods The endoscopic capsule (Pillcam SB1; Given Imaging, Yokneam, Israel) was administered to 80 patients with functional bowel disorders and 70 healthy subjects. Endoluminal image analysis was performed with a computer vision program developed for the evaluation of contractile events (luminal occlusions and radial wrinkles), non-contractile patterns (open tunnel and smooth wall patterns), type of content (secretions, chyme) and motion of wall and contents. Normality range and discrimination of abnormal cases were established by a machine learning technique. Specifically, an iterative classifier (one-class support vector machine) was applied in a random population of 50 healthy subjects as a training set and the remaining subjects (20 healthy subjects and 80 patients) as a test set.
 Key Results The classifier identified as abnormal 29% of patients with functional diseases of the bowel (23 of 80), and as normal 97% of healthy subjects (68 of 70) (P < 0.05 by chi-squared test). Patients identified as abnormal clustered in two groups, which exhibited either a hyper- or a hypodynamic motility pattern. The motor behavior was unrelated to clinical features.
Conclusions &  Inferences With appropriate methodology, abnormal intestinal motility can be demonstrated in a significant proportion of patients with functional bowel disorders, implying a pathologic disturbance of gut physiology.
 
  Address  
  Corporate Author Thesis  
  Publisher Wiley Online Library Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes MILAB; OR; MV Approved no  
  Call Number Admin @ si @ MLS2012 Serial 1830  
Permanent link to this record
 

 
Author (up) Carolina Malagelada; Michal Drozdzal; Santiago Segui; Sara Mendez; Jordi Vitria; Petia Radeva; Javier Santos; Anna Accarino; Juan R. Malagelada; Fernando Azpiroz edit  doi
openurl 
  Title Classification of functional bowel disorders by objective physiological criteria based on endoluminal image analysis Type Journal Article
  Year 2015 Publication American Journal of Physiology-Gastrointestinal and Liver Physiology Abbreviated Journal AJPGI  
  Volume 309 Issue 6 Pages G413--G419  
  Keywords capsule endoscopy; computer vision analysis; functional bowel disorders; intestinal motility; machine learning  
  Abstract We have previously developed an original method to evaluate small bowel motor function based on computer vision analysis of endoluminal images obtained by capsule endoscopy. Our aim was to demonstrate intestinal motor abnormalities in patients with functional bowel disorders by endoluminal vision analysis. Patients with functional bowel disorders (n = 205) and healthy subjects (n = 136) ingested the endoscopic capsule (Pillcam-SB2, Given-Imaging) after overnight fast and 45 min after gastric exit of the capsule a liquid meal (300 ml, 1 kcal/ml) was administered. Endoluminal image analysis was performed by computer vision and machine learning techniques to define the normal range and to identify clusters of abnormal function. After training the algorithm, we used 196 patients and 48 healthy subjects, completely naive, as test set. In the test set, 51 patients (26%) were detected outside the normal range (P < 0.001 vs. 3 healthy subjects) and clustered into hypo- and hyperdynamic subgroups compared with healthy subjects. Patients with hypodynamic behavior (n = 38) exhibited less luminal closure sequences (41 ± 2% of the recording time vs. 61 ± 2%; P < 0.001) and more static sequences (38 ± 3 vs. 20 ± 2%; P < 0.001); in contrast, patients with hyperdynamic behavior (n = 13) had an increased proportion of luminal closure sequences (73 ± 4 vs. 61 ± 2%; P = 0.029) and more high-motion sequences (3 ± 1 vs. 0.5 ± 0.1%; P < 0.001). Applying an original methodology, we have developed a novel classification of functional gut disorders based on objective, physiological criteria of small bowel function.  
  Address  
  Corporate Author Thesis  
  Publisher American Physiological Society Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes MILAB; OR;MV Approved no  
  Call Number Admin @ si @ MDS2015 Serial 2666  
Permanent link to this record
 

 
Author (up) Ciprian Corneanu; Marc Oliu; Jeffrey F. Cohn; Sergio Escalera edit   pdf
doi  openurl
  Title Survey on RGB, 3D, Thermal, and Multimodal Approaches for Facial Expression Recognition: History Type Journal Article
  Year 2016 Publication IEEE Transactions on Pattern Analysis and Machine Intelligence Abbreviated Journal TPAMI  
  Volume 28 Issue 8 Pages 1548-1568  
  Keywords Facial expression; affect; emotion recognition; RGB; 3D; thermal; multimodal  
  Abstract Facial expressions are an important way through which humans interact socially. Building a system capable of automatically recognizing facial expressions from images and video has been an intense field of study in recent years. Interpreting such expressions remains challenging and much research is needed about the way they relate to human affect. This paper presents a general overview of automatic RGB, 3D, thermal and multimodal facial expression analysis. We define a new taxonomy for the field, encompassing all steps from face detection to facial expression recognition, and describe and classify the state of the art methods accordingly. We also present the important datasets and the bench-marking of most influential methods. We conclude with a general discussion about trends, important questions and future lines of research.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes HuPBA;MILAB; Approved no  
  Call Number Admin @ si @ COC2016 Serial 2718  
Permanent link to this record
 

 
Author (up) Cristina Cañero; Fernando Vilariño; Petia Radeva edit  openurl
  Title Predictive (un) distortion model and 3D Reconstruction by Biplane Snakes Type Journal
  Year 2002 Publication IEEE Transactions on Medical Imaging (IF: 2.911) Abbreviated Journal  
  Volume Issue Pages  
  Keywords  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes MILAB;SIAI Approved no  
  Call Number BCNPCL @ bcnpcl @ CVR2002 Serial 269  
Permanent link to this record
Select All    Deselect All
 |   | 
Details

Save Citations:
Export Records: