toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
  Records Links
Author Josep Llados; Ernest Valveny; Enric Marti edit  isbn
openurl 
  Title Symbol Recognition in Document Image Analysis: Methods and Challenges Type Journal Article
  Year 2000 Publication Recent Research Developments in Pattern Recognition, Transworld Research Network, Abbreviated Journal  
  Volume 1 Issue Pages 151–178.  
  Keywords  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication (up) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN 81-86846-61-1 Medium  
  Area Expedition Conference  
  Notes DAG;IAM Approved no  
  Call Number IAM @ iam @ LVM2000 Serial 1575  
Permanent link to this record
 

 
Author Josep Llados; Enric Marti; Juan J.Villanueva edit  openurl
  Title Symbol recognition by error-tolerant subgraph matching between region adjacency graphs Type Journal Article
  Year 2001 Publication IEEE Transactions on Pattern Analysis and Machine Intelligence Abbreviated Journal  
  Volume 23 Issue 10 Pages 1137-1143  
  Keywords  
  Abstract The recognition of symbols in graphic documents is an intensive research activity in the community of pattern recognition and document analysis. A key issue in the interpretation of maps, engineering drawings, diagrams, etc. is the recognition of domain dependent symbols according to a symbol database. In this work we first review the most outstanding symbol recognition methods from two different points of view: application domains and pattern recognition methods. In the second part of the paper, open and unaddressed problems involved in symbol recognition are described, analyzing their current state of art and discussing future research challenges. Thus, issues such as symbol representation, matching, segmentation, learning, scalability of recognition methods and performance evaluation are addressed in this work. Finally, we discuss the perspectives of symbol recognition concerning to new paradigms such as user interfaces in handheld computers or document database and WWW indexing by graphical content.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication (up) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes DAG;IAM;ISE; Approved no  
  Call Number IAM @ iam @ LMV2001 Serial 1581  
Permanent link to this record
 

 
Author Maurizio Mencuccini; Jordi Martinez-Vilalta; Josep Piñol; Lasse Loepfe; Mireia Burnat ; Xavier Alvarez; Juan Camacho; Debora Gil edit   pdf
url  doi
openurl 
  Title A quantitative and statistically robust method for the determination of xylem conduit spatial distribution Type Journal Article
  Year 2010 Publication American Journal of Botany Abbreviated Journal AJB  
  Volume 97 Issue 8 Pages 1247-1259  
  Keywords Geyer; hydraulic conductivity; point pattern analysis; Ripley; Spatstat; vessel clusters; xylem anatomy; xylem network  
  Abstract Premise of the study: Because of their limited length, xylem conduits need to connect to each other to maintain water transport from roots to leaves. Conduit spatial distribution in a cross section plays an important role in aiding this connectivity. While indices of conduit spatial distribution already exist, they are not well defined statistically. * Methods: We used point pattern analysis to derive new spatial indices. One hundred and five cross-sectional images from different species were transformed into binary images. The resulting point patterns, based on the locations of the conduit centers-of-area, were analyzed to determine whether they departed from randomness. Conduit distribution was then modeled using a spatially explicit stochastic model. * Key results: The presence of conduit randomness, uniformity, or aggregation depended on the spatial scale of the analysis. The large majority of the images showed patterns significantly different from randomness at least at one spatial scale. A strong phylogenetic signal was detected in the spatial variables. * Conclusions: Conduit spatial arrangement has been largely conserved during evolution, especially at small spatial scales. Species in which conduits were aggregated in clusters had a lower conduit density compared to those with uniform distribution. Statistically sound spatial indices must be employed as an aid in the characterization of distributional patterns across species and in models of xylem water transport. Point pattern analysis is a very useful tool in identifying spatial patterns.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication (up) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes IAM; Approved no  
  Call Number IAM @ iam @ MMG2010 Serial 1623  
Permanent link to this record
 

 
Author Oriol Rodriguez-Leon.A.Carol;H.Tizon; Eduard Fernandez-Nofrerias; Josefina Mauri; Vicente del Valle; Debora Gil; Aura Hernandez-Sabate; Petia Radeva edit  openurl
  Title Model estadístic-determinístic per la segmentació de l adventicia en imatges d ecografía intracoronaria Type Journal Article
  Year 2005 Publication Rev Societat Catalana Cardiologia Abbreviated Journal  
  Volume 5 Issue Pages 41  
  Keywords  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication (up) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes IAM;MILAB Approved no  
  Call Number IAM @ iam @ RCT2005 Serial 1637  
Permanent link to this record
 

 
Author Oriol Rodriguez-Leon; Debora Gil; Eduard Fernandez-Nofrerias edit  openurl
  Title Analisis en los cambios en el nivel de gris en las secuencias angiograficas mediante descriptores estadisticos para determinar la perfusion miocardica Type Journal Article
  Year 2006 Publication Revista Española de Cardiología Abbreviated Journal REC  
  Volume 59 Supl 2-166 Issue 2 Pages 128  
  Keywords  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication (up) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes IAM; Approved no  
  Call Number IAM @ iam @ RGF2006 Serial 1640  
Permanent link to this record
 

 
Author Oriol Rodriguez-Leon; Josefina Mauri;Eduard Fernandez-Nofrerias; C.Garcia; R.Villuendas; Vicente del Valle; Debora Gil;Petia Radeva edit  openurl
  Title Reconstruction of a spatio-temporal model of the intima layer from intravascular ultrasound sequences Type Journal Article
  Year 2003 Publication European Heart Journal Abbreviated Journal  
  Volume Issue Pages  
  Keywords  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication (up) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference ESC Congress  
  Notes IAM;MILAB Approved no  
  Call Number IAM @ iam @ RMF2003c Serial 1641  
Permanent link to this record
 

 
Author Oriol Rodriguez-Leon; Josefina Mauri;Eduard Fernandez-Nofrerias; Antonio Tovar; Vicente del Valle; Aura Hernandez-Sabate; Debora Gil; Petia Radeva edit  openurl
  Title Utilización de la Estructura de los Campos Vectoriales para la Detección de la Adventicia en Imágenes de Ecografía Intracoronaria Type Journal Article
  Year 2004 Publication Revista Internacional de Enfermedades Cardiovasculares Revista Española de Cardiología Abbreviated Journal  
  Volume 57 Issue 2 Pages 100  
  Keywords  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication (up) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference SEC  
  Notes IAM;MILAB Approved no  
  Call Number IAM @ iam @ RMF2004 Serial 1642  
Permanent link to this record
 

 
Author Misael Rosales; Petia Radeva;Oriol Rodriguez-Leon; Debora Gil edit   pdf
doi  openurl
  Title Modelling of image-catheter motion for 3-D IVUS Type Journal Article
  Year 2009 Publication Medical image analysis Abbreviated Journal MIA  
  Volume 13 Issue 1 Pages 91-104  
  Keywords Intravascular ultrasound (IVUS); Motion estimation; Motion decomposition; Fourier  
  Abstract Three-dimensional intravascular ultrasound (IVUS) allows to visualize and obtain volumetric measurements of coronary lesions through an exploration of the cross sections and longitudinal views of arteries. However, the visualization and subsequent morpho-geometric measurements in IVUS longitudinal cuts are subject to distortion caused by periodic image/vessel motion around the IVUS catheter. Usually, to overcome the image motion artifact ECG-gating and image-gated approaches are proposed, leading to slowing the pullback acquisition or disregarding part of IVUS data. In this paper, we argue that the image motion is due to 3-D vessel geometry as well as cardiac dynamics, and propose a dynamic model based on the tracking of an elliptical vessel approximation to recover the rigid transformation and align IVUS images without loosing any IVUS data. We report an extensive validation with synthetic simulated data and in vivo IVUS sequences of 30 patients achieving an average reduction of the image artifact of 97% in synthetic data and 79% in real-data. Our study shows that IVUS alignment improves longitudinal analysis of the IVUS data and is a necessary step towards accurate reconstruction and volumetric measurements of 3-D IVUS.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication (up) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes IAM;MILAB Approved no  
  Call Number IAM @ iam @ RRR2009 Serial 1646  
Permanent link to this record
 

 
Author David Rotger; Misael Rosales; Jaume Garcia; Oriol Pujol ; Josefina Mauri; Petia Radeva edit   pdf
openurl 
  Title Active Vessel: A New Multimedia Workstation for Intravascular Ultrasound and Angiography Fusion Type Journal Article
  Year 2003 Publication Computers in Cardiology Abbreviated Journal  
  Volume 30 Issue Pages 65-68  
  Keywords  
  Abstract AcriveVessel is a new multimedia workstation which enables the visualization, acquisition and handling of both image modalities, on- and ofline. It enables DICOM v3.0 decompression and browsing, video acquisition,repmduction and storage for IntraVascular UltraSound (IVUS) and angiograms with their corresponding ECG,automatic catheter segmentation in angiography images (using fast marching algorithm). BSpline models definition for vessel layers on IVUS images sequence and an extensively validated tool to fuse information. This approach defines the correspondence of every IVUS image with its correspondent point in the angiogram and viceversa. The 3 0 reconstruction of the NUS catheterhessel enables real distance measurements as well as threedimensional visualization showing vessel tortuosity in the space.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication (up) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes IAM;MILAB;HuPBA Approved no  
  Call Number IAM @ iam @ RRG2003 Serial 1647  
Permanent link to this record
 

 
Author Ernest Valveny; Enric Marti edit   pdf
doi  openurl
  Title Deformable Template Matching within a Bayesian Framework for Hand-Written Graphic Symbol Recognition Type Journal Article
  Year 2000 Publication Graphics Recognition Recent Advances Abbreviated Journal  
  Volume 1941 Issue Pages 193-208  
  Keywords  
  Abstract We describe a method for hand-drawn symbol recognition based on deformable template matching able to handle uncertainty and imprecision inherent to hand-drawing. Symbols are represented as a set of straight lines and their deformations as geometric transformations of these lines. Matching, however, is done over the original binary image to avoid loss of information during line detection. It is defined as an energy minimization problem, using a Bayesian framework which allows to combine fidelity to ideal shape of the symbol and flexibility to modify the symbol in order to get the best fit to the binary input image. Prior to matching, we find the best global transformation of the symbol to start the recognition process, based on the distance between symbol lines and image lines. We have applied this method to the recognition of dimensions and symbols in architectural floor plans and we show its flexibility to recognize distorted symbols.  
  Address  
  Corporate Author Springer Verlag Thesis  
  Publisher Springer Verlag Place of Publication (up) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes DAG;IAM; Approved no  
  Call Number IAM @ iam @ MVA2000 Serial 1655  
Permanent link to this record
Select All    Deselect All
 |   | 
Details

Save Citations:
Export Records: