|
Records |
Links |
|
Author |
Eric Amiel |


|
|
Title |
Visualisation de vaisseaux sanguins |
Type |
Report |
|
Year |
2005 |
Publication |
Rapport de Stage |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
Université Paul Sabatier Toulouse III |
Thesis |
Bachelor's thesis |
|
|
Publisher |
Université Paul Sabatier Toulouse III |
Place of Publication |
Toulouse |
Editor  |
Enric Marti |
|
|
Language |
French |
Summary Language |
French |
Original Title |
|
|
|
Series Editor |
IUP Systèmes Intelligents |
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ Ami2005 |
Serial |
1690 |
|
Permanent link to this record |
|
|
|
|
Author |
Joan M. Nuñez |

|
|
Title |
Computer vision techniques for characterization of finger joints in X-ray image |
Type |
Report |
|
Year |
2011 |
Publication |
CVC Technical Report |
Abbreviated Journal |
|
|
|
Volume |
165 |
Issue |
|
Pages |
|
|
|
Keywords |
Rheumatoid arthritis, X-ray, Sharp Van der Heijde, joint characterization, sclerosis detection, bone detection, edge, ridge |
|
|
Abstract |
Rheumatoid arthritis (RA) is an autoimmune inflammatory type of arthritis which mainly affects hands on its first stages. Though it is a chronic disease and there is no cure for it, treatments require an accurate assessment of illness evolution. Such assessment is based on evaluation of hand X-ray images by using one of the several available semi-quantitative methods. This task requires highly trained medical personnel. That is why the automation of the assessment would allow professionals to save time and effort. Two stages are involved in this task. Firstly, the joint detection, afterwards, the joint characterization. Unlike the little existing previous work, this contribution clearly separates those two stages and sets the foundations of a modular assessment system focusing on the characterization stage. A hand joint dataset is created and an accurate data analysis is achieved in order to identify relevant features. Since the sclerosis and the lower bone were decided to be the most important features, different computer vision techniques were used in order to develop a detector system for both of them. Joint space width measures are provided and their correlation with Sharp-Van der Heijde is verified |
|
|
Address |
Bellaterra (Barcelona) |
|
|
Corporate Author |
Computer Vision Center |
Thesis |
Master's thesis |
|
|
Publisher |
|
Place of Publication |
|
Editor  |
Dr. Fernando Vilariño and Dra. Debora Gil |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
MV;IAM; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ Nuñ2011 |
Serial |
1795 |
|
Permanent link to this record |
|
|
|
|
Author |
Josep Llados; Ernest Valveny; Gemma Sanchez; Enric Marti |



|
|
Title |
Symbol recognition: current advances and perspectives |
Type |
Book Chapter |
|
Year |
2002 |
Publication |
Graphics Recognition Algorithms And Applications |
Abbreviated Journal |
LNCS |
|
|
Volume |
2390 |
Issue |
|
Pages |
104-128 |
|
|
Keywords |
|
|
|
Abstract |
The recognition of symbols in graphic documents is an intensive research activity in the community of pattern recognition and document analysis. A key issue in the interpretation of maps, engineering drawings, diagrams, etc. is the recognition of domain dependent symbols according to a symbol database. In this work we first review the most outstanding symbol recognition methods from two different points of view: application domains and pattern recognition methods. In the second part of the paper, open and unaddressed problems involved in symbol recognition are described, analyzing their current state of art and discussing future research challenges. Thus, issues such as symbol representation, matching, segmentation, learning, scalability of recognition methods and performance evaluation are addressed in this work. Finally, we discuss the perspectives of symbol recognition concerning to new paradigms such as user interfaces in handheld computers or document database and WWW indexing by graphical content. |
|
|
Address |
London, UK |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer-Verlag |
Place of Publication |
|
Editor  |
Dorothea Blostein and Young- Bin Kwon |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
Lecture Notes in Computer Science |
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
3-540-44066-6 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
GREC |
|
|
Notes |
DAG; IAM; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ LVS2002 |
Serial |
1572 |
|
Permanent link to this record |
|
|
|
|
Author |
Sergio Vera |

|
|
Title |
Anatomic Registration based on Medial Axis Parametrizations |
Type |
Book Whole |
|
Year |
2015 |
Publication |
PhD Thesis, Universitat Autonoma de Barcelona-CVC |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
Image registration has been for many years the gold standard method to bring two images into correspondence. It has been used extensively in the eld of medical imaging in order to put images of dierent patients into a common overlapping spatial position. However, medical image registration is a slow, iterative optimization process, where many variables and prone to fall into the pit traps local minima.
A coordinate system parameterizing the interior of organs is a powerful tool for a systematic localization of injured tissue. If the same coordinate values are assigned to specic anatomical sites, parameterizations ensure integration of data across different medical image modalities. Harmonic mappings have been used to produce parametric meshes over the surface of anatomical shapes, given their ability to set values at specic locations through boundary conditions. However, most of the existing implementations in medical imaging restrict to either anatomical surfaces, or the depth coordinate with boundary conditions is given at discrete sites of limited geometric diversity.
The medial surface of the shape can be used to provide a continuous basis for the denition of a depth coordinate. However, given that dierent methods for generation of medial surfaces generate dierent manifolds, not all of them are equally suited to be the basis of radial coordinate for a parameterization. It would be desirable that the medial surface will be smooth, and robust to surface shape noise, with low number of spurious branches or surfaces.
In this thesis we present methods for computation of smooth medial manifolds and apply them to the generation of for anatomical volumetric parameterization that extends current harmonic parameterizations to the interior anatomy using information provided by the volume medial surface. This reference system sets a solid base for creating anatomical models of the anatomical shapes, and allows comparing several patients in a common framework of reference. |
|
|
Address |
November 2015 |
|
|
Corporate Author |
|
Thesis |
Ph.D. thesis |
|
|
Publisher |
Ediciones Graficas Rey |
Place of Publication |
|
Editor  |
Debora Gil;Miguel Angel Gonzalez Ballester |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-84-943427-8-3 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; 600.075 |
Approved |
no |
|
|
Call Number |
Admin @ si @ Ver2015 |
Serial |
2708 |
|
Permanent link to this record |
|
|
|
|
Author |
David Roche |

|
|
Title |
A Statistical Framework for Terminating Evolutionary Algorithms at their Steady State |
Type |
Book Whole |
|
Year |
2015 |
Publication |
PhD Thesis, Universitat Autonoma de Barcelona-CVC |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
As any iterative technique, it is a necessary condition a stop criterion for terminating Evolutionary Algorithms (EA). In the case of optimization methods, the algorithm should stop at the time it has reached a steady state so it can not improve results anymore. Assessing the reliability of termination conditions for EAs is of prime importance. A wrong or weak stop criterion can negatively aect both the computational eort and the nal result.
In this Thesis, we introduce a statistical framework for assessing whether a termination condition is able to stop EA at its steady state. In one hand a numeric approximation to steady states to detect the point in which EA population has lost its diversity has been presented for EA termination. This approximation has been applied to dierent EA paradigms based on diversity and a selection of functions covering the properties most relevant for EA convergence. Experiments show that our condition works regardless of the search space dimension and function landscape and Dierential Evolution (DE) arises as the best paradigm. On the other hand, we use a regression model in order to determine the requirements ensuring that a measure derived from EA evolving population is related to the distance to the optimum in xspace.
Our theoretical framework is analyzed across several benchmark test functions
and two standard termination criteria based on function improvement in f-space and EA population x-space distribution for the DE paradigm. Results validate our statistical framework as a powerful tool for determining the capability of a measure for terminating EA and select the x-space distribution as the best-suited for accurately stopping DE in real-world applications. |
|
|
Address |
July 2015 |
|
|
Corporate Author |
|
Thesis |
Ph.D. thesis |
|
|
Publisher |
Ediciones Graficas Rey |
Place of Publication |
|
Editor  |
Debora Gil;Jesus Giraldo |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; 600.075 |
Approved |
no |
|
|
Call Number |
Admin @ si @ Roc2015 |
Serial |
2686 |
|
Permanent link to this record |
|
|
|
|
Author |
Ferran Poveda |

|
|
Title |
Computer Graphics and Vision Techniques for the Study of the Muscular Fiber Architecture of the Myocardium |
Type |
Book Whole |
|
Year |
2013 |
Publication |
PhD Thesis, Universitat Autonoma de Barcelona-CVC |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
Ph.D. thesis |
|
|
Publisher |
|
Place of Publication |
|
Editor  |
Debora Gil;Enric Marti |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
Admin @ si @ Pov2013 |
Serial |
2417 |
|
Permanent link to this record |
|
|
|
|
Author |
Antonio Esteban Lansaque |

|
|
Title |
An Endoscopic Navigation System for Lung Cancer Biopsy |
Type |
Book Whole |
|
Year |
2019 |
Publication |
PhD Thesis, Universitat Autonoma de Barcelona-CVC |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
Lung cancer is one of the most diagnosed cancers among men and women. Actually,
lung cancer accounts for 13% of the total cases with a 5-year global survival
rate in patients. Although Early detection increases survival rate from 38% to 67%, accurate diagnosis remains a challenge. Pathological confirmation requires extracting a sample of the lesion tissue for its biopsy. The preferred procedure for tissue biopsy is called bronchoscopy. A bronchoscopy is an endoscopic technique for the internal exploration of airways which facilitates the performance of minimal invasive interventions with low risk for the patient. Recent advances in bronchoscopic devices have increased their use for minimal invasive diagnostic and intervention procedures, like lung cancer biopsy sampling. Despite the improvement in bronchoscopic device quality, there is a lack of intelligent computational systems for supporting in-vivo clinical decision during examinations. Existing technologies fail to accurately reach the lesion due to several aspects at intervention off-line planning and poor intra-operative guidance at exploration time. Existing guiding systems radiate patients and clinical staff,might be expensive and achieve a suboptimlal 70% of yield boost. Diagnostic yield could be improved reducing radiation and costs by developing intra-operative support systems able to guide the bronchoscopist to the lesion during the intervention. The goal of this PhD thesis is to develop an image-based navigation systemfor intra-operative guidance of bronchoscopists to a target lesion across a path previously planned on a CT-scan. We propose a 3D navigation system which uses the anatomy of video bronchoscopy frames to locate the bronchoscope within the airways. Once the bronchoscope is located, our navigation system is able to indicate the bifurcation which needs to be followed to reach the lesion. In order to facilitate an off-line validation
as realistic as possible, we also present a method for augmenting simulated virtual bronchoscopies with the appearance of intra-operative videos. Experiments performed on augmented and intra-operative videos, prove that our algorithm can be speeded up for an on-line implementation in the operating room. |
|
|
Address |
October 2019 |
|
|
Corporate Author |
|
Thesis |
Ph.D. thesis |
|
|
Publisher |
Ediciones Graficas Rey |
Place of Publication |
|
Editor  |
Debora Gil;Carles Sanchez |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-84-121011-0-2 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; 600.139; 600.145 |
Approved |
no |
|
|
Call Number |
Admin @ si @ Est2019 |
Serial |
3392 |
|
Permanent link to this record |
|
|
|
|
Author |
Patricia Marquez |

|
|
Title |
A Confidence Framework for the Assessment of Optical Flow Performance |
Type |
Book Whole |
|
Year |
2015 |
Publication |
PhD Thesis, Universitat Autonoma de Barcelona-CVC |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
Optical Flow (OF) is the input of a wide range of decision support systems such as car driver assistance, UAV guiding or medical diagnose. In these real situations, the absence of ground truth forces to assess OF quality using quantities computed from either sequences or the computed optical flow itself. These quantities are generally known as Confidence Measures, CM. Even if we have a proper confidence measure we still need a way to evaluate its ability to discard pixels with an OF prone to have a large error. Current approaches only provide a descriptive evaluation of the CM performance but such approaches are not capable to fairly compare different confidence measures and optical flow algorithms. Thus, it is of prime importance to define a framework and a general road map for the evaluation of optical flow performance.
This thesis provides a framework able to decide which pairs “ optical flow – confidence measure” (OF-CM) are best suited for optical flow error bounding given a confidence level determined by a decision support system. To design this framework we cover the following points:
Descriptive scores. As a first step, we summarize and analyze the sources of inaccuracies in the output of optical flow algorithms. Second, we present several descriptive plots that visually assess CM capabilities for OF error bounding. In addition to the descriptive plots, given a plot representing OF-CM capabilities to bound the error, we provide a numeric score that categorizes the plot according to its decreasing profile, that is, a score assessing CM performance.
Statistical framework. We provide a comparison framework that assesses the best suited OF-CM pair for error bounding that uses a two stage cascade process. First of all we assess the predictive value of the confidence measures by means of a descriptive plot. Then, for a sample of descriptive plots computed over training frames, we obtain a generic curve that will be used for sequences with no ground truth. As a second step, we evaluate the obtained general curve and its capabilities to really reflect the predictive value of a confidence measure using the variability across train frames by means of ANOVA.
The presented framework has shown its potential in the application on clinical decision support systems. In particular, we have analyzed the impact of the different image artifacts such as noise and decay to the output of optical flow in a cardiac diagnose system and we have improved the navigation inside the bronchial tree on bronchoscopy. |
|
|
Address |
July 2015 |
|
|
Corporate Author |
|
Thesis |
Ph.D. thesis |
|
|
Publisher |
Ediciones Graficas Rey |
Place of Publication |
|
Editor  |
Debora Gil;Aura Hernandez |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-84-943427-2-1 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; 600.075 |
Approved |
no |
|
|
Call Number |
Admin @ si @ Mar2015 |
Serial |
2687 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Jordi Gonzalez; Gemma Sanchez (eds) |

|
|
Title |
Computer Vision: Advances in Research and Development |
Type |
Book Whole |
|
Year |
2007 |
Publication |
Proceedings of the 2nd CVC International Workshop |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
UAB |
Place of Publication |
Bellaterra (Spain) |
Editor  |
Debora Gil; Jordi Gonzalez; Gemma Sanchez |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
2 |
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-84-935251-4-9 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; ISE; DAG |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GGS2007 |
Serial |
1493 |
|
Permanent link to this record |
|
|
|
|
Author |
Carles Sanchez |

|
|
Title |
Tracheal ring detection in bronchoscopy |
Type |
Report |
|
Year |
2011 |
Publication |
CVC Technical Report |
Abbreviated Journal |
|
|
|
Volume |
168 |
Issue |
|
Pages |
|
|
|
Keywords |
Bronchoscopy, tracheal ring, segmentation |
|
|
Abstract |
Endoscopy is the process in which a camera is introduced inside a human.
Given that endoscopy provides realistic images (in contrast to other modalities) and allows non-invase minimal intervention procedures (which can aid in diagnosis and surgical interventions), its use has spreaded during last decades.
In this project we will focus on bronchoscopic procedures, during which the camera is introduced through the trachea in order to have a diagnostic of the patient. The diagnostic interventions are focused on: degree of stenosis (reduction in tracheal area), prosthesis or early diagnosis of tumors. In the first case, assessment of the luminal area and the calculation of the diameters of the tracheal rings are required. A main limitation is that all the process is done by hand,
which means that the doctor takes all the measurements and decisions just by looking at the screen. As far as we know there is no computational framework for helping the doctors in the diagnosis.
This project will consist of analysing bronchoscopic videos in order to extract useful information for the diagnostic of the degree of stenosis. In particular we will focus on segmentation of the tracheal rings. As a result of this project several strategies (for detecting tracheal rings) had been implemented in order to compare their performance. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
Master's thesis |
|
|
Publisher |
|
Place of Publication |
|
Editor  |
Debora Gil, F.Javier Sanchez |
|
|
Language |
english |
Summary Language |
english |
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MV |
Approved |
no |
|
|
Call Number |
IAM @ iam @ San2011 |
Serial |
1841 |
|
Permanent link to this record |