Author Joel Barajas; Jaume Garcia; Francesc Carreras; Sandra Pujades; Petia Radeva edit   pdf
url  isbn
openurl 
  Title Angle Images Using Gabor Filters in Cardiac Tagged MRI Type Conference Article
  Year 2005 Publication Proceeding of the 2005 conference on Artificial Intelligence Research and Development Abbreviated Journal  
  Volume Issue Pages 107-114  
  Keywords Angle Images, Gabor Filters, Harp, Tagged Mri  
  Abstract Tagged Magnetic Resonance Imaging (MRI) is a non-invasive technique used to examine cardiac deformation in vivo. An Angle Image is a representation of a Tagged MRI which recovers the relative position of the tissue respect to the distorted tags. Thus cardiac deformation can be estimated. This paper describes a new approach to generate Angle Images using a bank of Gabor filters in short axis cardiac Tagged MRI. Our method improves the Angle Images obtained by global techniques, like HARP, with a local frequency analysis. We propose to use the phase response of a combination of a Gabor filters bank, and use it to find a more precise deformation of the left ventricle. We demonstrate the accuracy of our method over HARP by several experimental results.  
  Address Amsterdam; The Netherlands  
  Corporate Author Thesis  
  Publisher IOS Press Place of Publication Amsterdam, The Netherlands Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN 1-58603-560-6 Medium  
  Area (up) Expedition Conference CAIRD  
  Notes IAM;MILAB Approved no  
  Call Number BCNPCL @ bcnpcl @ BGC2005; IAM @ iam Serial 595  
Permanent link to this record
 

 
Author Jaume Garcia; Joel Barajas; Francesc Carreras; Sandra Pujades; Petia Radeva edit   pdf
doi  isbn
openurl 
  Title An intuitive validation technique to compare local versus global tagged MRI analysis Type Conference Article
  Year 2005 Publication Computers In Cardiology Abbreviated Journal  
  Volume 32 Issue Pages 29–32  
  Keywords  
  Abstract Myocardium appears as a uniform tissue that seen in convectional Magnetic Resonance Images (MRI) shows just the contractile part of its movement. MR Tagging is a unique imaging technique that prints a grid over the tissue which moves according to the underlying movement of the myocardium revealing the true deformation of the cardiac muscle. Optical flow techniques based on spectral information estimate tissue displacement by analyzing information encoded in the phase maps which can be obtained using, local (Gabor) and global (HARP) methods. In this paper we compare both in synthetic and real Tagged MR sequences. We conclude that local method is slightly more accurate than the global one. On the other hand, global method is more efficient as it is much faster and less parameters have to be taken into account  
  Address Lyon (France)  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN 0-7803-9337-6 Medium  
  Area (up) Expedition Conference  
  Notes IAM;MILAB Approved no  
  Call Number IAM @ iam @ GBC2005 Serial 639  
Permanent link to this record
 

 
Author Debora Gil; Jaume Garcia; Mariano Vazquez; Ruth Aris; Guilleaume Houzeaux edit   pdf
isbn  openurl
  Title Patient-Sensitive Anatomic and Functional 3D Model of the Left Ventricle Function Type Conference Article
  Year 2008 Publication 8th World Congress on Computational Mechanichs (WCCM8) Abbreviated Journal  
  Volume Issue Pages  
  Keywords Left Ventricle, Electromechanical Models, Image Processing, Magnetic Resonance.  
  Abstract Early diagnosis and accurate treatment of Left Ventricle (LV) dysfunction significantly increases the patient survival. Impairment of LV contractility due to cardiovascular diseases is reflected in its motion patterns. Recent advances in medical imaging, such as Magnetic Resonance (MR), have encouraged research on 3D simulation and modelling of the LV dynamics. Most of the existing 3D models [1] consider just the gross anatomy of the LV and restore a truncated ellipse which deforms along the cardiac cycle. The contraction mechanics of any muscle strongly depends on the spatial orientation of its muscular fibers since the motion that the muscle undergoes mainly takes place along the fibers. It follows that such simplified models do not allow evaluation of the heart electro-mechanical function and coupling, which has recently risen as the key point for understanding the LV functionality [2]. In order to thoroughly understand the LV mechanics it is necessary to consider the complete anatomy of the LV given by the orientation of the myocardial fibres in 3D space as described by Torrent Guasp [3].
We propose developing a 3D patient-sensitive model of the LV integrating, for the first time, the ven- tricular band anatomy (fibers orientation), the LV gross anatomy and its functionality. Such model will represent the LV function as a natural consequence of its own ventricular band anatomy. This might be decisive in restoring a proper LV contraction in patients undergoing pace marker treatment.
The LV function is defined as soon as the propagation of the contractile electromechanical pulse has been modelled. In our experiments we have used the wave equation for the propagation of the electric pulse. The electromechanical wave moves on the myocardial surface and should have a conductivity tensor oriented along the muscular fibers. Thus, whatever mathematical model for electric pulse propa- gation [4] we consider, the complete anatomy of the LV should be extracted.
The LV gross anatomy is obtained by processing multi slice MR images recorded for each patient. Information about the myocardial fibers distribution can only be extracted by Diffusion Tensor Imag- ing (DTI), which can not provide in vivo information for each patient. As a first approach, we have
Figure 1: Scheme for the Left Ventricle Patient-Sensitive Model.
computed an average model of fibers from several DTI studies of canine hearts. This rough anatomy is the input for our electro-mechanical propagation model simulating LV dynamics. The average fiber orientation is updated until the simulated LV motion agrees with the experimental evidence provided by the LV motion observed in tagged MR (TMR) sequences. Experimental LV motion is recovered by applying image processing, differential geometry and interpolation techniques to 2D TMR slices [5]. The pipeline in figure 1 outlines the interaction between simulations and experimental data leading to our patient-tailored model.
 
  Address Venice; Italy  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN 9788496736559 Medium  
  Area (up) Expedition Conference  
  Notes IAM; Approved no  
  Call Number IAM @ iam @ GGV2008b Serial 993  
Permanent link to this record
 

 
Author C. Santa-Marta; Jaume Garcia; A. Bajo; J.J. Vaquero; M. Ledesma-Carbayo; Debora Gil edit  openurl
  Title Influence of the Temporal Resolution on the Quantification of Displacement Fields in Cardiac Magnetic Resonance Tagged Images Type Conference Article
  Year 2008 Publication XXVI Congreso Anual de la Sociedad Española de Ingenieria Biomedica Abbreviated Journal  
  Volume Issue Pages 352–353  
  Keywords  
  Abstract It is difficult to acquire tagged cardiac MR images with a high temporal and spatial resolution using clinical MR scanners. However, if such images are used for quantifying scores based on motion, it is essential a resolution as high as possibl e. This paper explores the influence of the temporal resolution of a tagged series on the quantification of myocardial dynamic parameters. To such purpose we have designed a SPAMM (Spatial Modulation of Magnetization) sequence allowing acquisition of sequences at simple and double temporal resolution. Sequences are processed to compute myocardial motion by an automatic technique based on the tracking of the harmonic phase of tagged images (the Harmonic Phase Flow, HPF). The results have been compared to manual tracking of myocardial tags. The error in displacement fields for double resolution sequences reduces 17%.  
  Address Valladolid  
  Corporate Author Thesis  
  Publisher Place of Publication Editor Roberto hornero, Saniel Abasolo  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area (up) Expedition Conference CASEIB  
  Notes IAM; Approved no  
  Call Number IAM @ iam @ SGB2008 Serial 1033  
Permanent link to this record
 

 
Author Joel Barajas; Jaume Garcia; Karla Lizbeth Caballero; Francesc Carreras; Sandra Pujades; Petia Radeva edit   pdf
isbn  openurl
  Title Correction of Misalignment Artifacts Among 2-D Cardiac MR Images in 3-D Space Type Conference Article
  Year 2006 Publication 1st International Wokshop on Computer Vision for Intravascular and Intracardiac Imaging (CVII’06) Abbreviated Journal  
  Volume 3217 Issue Pages 114-121  
  Keywords  
  Abstract Cardiac Magnetic Resonance images offer the opportunity to study the heart in detail. One of the main issues in its modelling is to create an accurate 3-D reconstruction of the left ventricle from 2-D views. A first step to achieve this goal is the correct registration among the different image planes due to patient movements. In this article, we present an accurate method to correct displacement artifacts using the Normalized Mutual Information. Here, the image views are treated as planes in order to diminish the approximation error caused by the association of a certain thickness, and moved simultaneously to avoid any kind of bias in the alignment process. This method has been validated using real and syntectic plane displacements, yielding promising results.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Copenhagen (Denmark) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN 978-3-540-22977-3 Medium  
  Area (up) Expedition Conference  
  Notes IAM;MILAB Approved no  
  Call Number IAM @ iam @ BGC2006 Serial 1485  
Permanent link to this record
 

 
Author Jaume Garcia; Debora Gil; Francesc Carreras; Sandra Pujades; R.Leta; Xavier Alomar; Guillem Pons-LLados edit   pdf
url  openurl
  Title Patrons de Normalitat Regional per la Valoració de la Funció del Ventricle Esquerre Type Conference Article
  Year 2008 Publication XX Congrés de la Societat Catalana de Cardiologia Abbreviated Journal  
  Volume Issue Pages 60  
  Keywords  
  Abstract Les malalties cardiovasculars afecten les propietats contràctils de la banda ventricular i provoquen una variació de la funció del Ventricle Esquerre (VE) . Només els indicadors locals (strains, la deformació del teixit) són capaços de detectar anomalies en territoris específics del VE . Patrons de normalitat regionals d’aquests paràmetres serien d’utilitat a l’hora de valorar-ne la funció .
Presentem un Domini Paramètric Normalitzat (DPN) que permet comparar dades de diferents pacients i definir Patrons de Normalitat Regional (PNR)
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Barcelona Editor  
  Language catalan Summary Language catalan Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area (up) Expedition Conference  
  Notes IAM; Approved no  
  Call Number IAM @ iam @ GGC2008b Serial 1503  
Permanent link to this record
 

 
Author Jaume Garcia; Debora Gil; Francesc Carreras ; Sandra Pujades; R.Leta; Xavier Alomar; Guillem Pons-LLados edit   pdf
openurl 
  Title Un Model 3D del Ventricle Esquerre Integrant Anatomia i Funcionalitat Type Conference Article
  Year 2008 Publication XX Congrés de la Societat Catalana de Cardiologia, Actes del Congres Abbreviated Journal  
  Volume Issue Pages 122  
  Keywords  
  Abstract Els canvis en la dinàmica del Ventricle Esquerre (VE) reflecteixen la majoria de malalties cardiovasculars . Els avenços en imatge mèdica han impulsat la recerca en models i simulacions de la dinàmica 3D del VE . La majoria dels models existents sols consideren l’anatomia externa del VE i no permeten una avaluació de l’acoblament electromecànic . Donat que la mecànica d’un muscle depèn de la orientació de les seves fibres, un model realista hauria d’incloure la disposició espacial de la banda ventricular helicoidal (BVH) .
Proposem desenvolupar un model del VE adaptat a cada pacient que integri, per primer cop, l’anatomia de la banda ventricular, l’anatomia externa del VE i la seva funcionalitat, per a una millor determinació del patró d’activació electromecànica
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Barcelona Editor  
  Language catalan Summary Language catalan Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area (up) Expedition Conference  
  Notes IAM Approved no  
  Call Number IAM @ iam @ GGC2008c Serial 1504  
Permanent link to this record
 

 
Author Jaume Garcia; Debora Gil; Francesc Carreras; Sandra Pujades; R.Leta edit   pdf
openurl 
  Title Modelització 4-Dimensional de la Funció Siatólica del Ventricle Esquerre Type Conference Article
  Year 2007 Publication XIX Congrés de la Societat Catalana de Cardiologia de Barcelona Abbreviated Journal  
  Volume Issue Pages 133-134  
  Keywords  
  Abstract L’evolució tecnològica en el tractament de les imatges mèdiques permet reconstruir, amb el software apropiat, imatges tridimensionals de les estructures cardiovasculars i dotar-les de moviment. Les imatges 4D resultants faciliten l’estudi de la fisiopatologia de la insuficiència cardíaca en base als transtorns de l’activació electromecànica ventricular, el que pot ser d’interès en el procés de selecció de pacients candidats a teràpies de resincronització. Presentem els resultats preliminars de la reconstrucció 4D del ventricle esquerre (VE) a partir de les seqüències de tagging miocàrdic del VE.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Barcelona (Spain) Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area (up) Expedition Conference  
  Notes IAM Approved no  
  Call Number IAM @ iam @ GGC2007 Serial 1505  
Permanent link to this record
 

 
Author Jaume Garcia; Debora Gil; A.Bajo; M.J.Ledesma-Carbayo; C.SantaMarta edit   pdf
doi  openurl
  Title Influence of the temporal resolution on the quantification of displacement fields in cardiac magnetic resonance tagged images Type Conference Article
  Year 2008 Publication Proc. Computers in Cardiology Abbreviated Journal  
  Volume 35 Issue Pages 785-788  
  Keywords  
  Abstract It is difficult to acquire tagged cardiac MR images with a high temporal and spatial resolution using clinical MR scanners. However, if such images are used for quantifying scores based on motion, it is essential a resolution as high as possible. This paper explores the influence of the temporal resolution of a tagged series on the quantification of myocardial dynamic parameters. To such purpose we have designed a SPAMM (Spatial Modulation of Magnetization) sequence allowing acquisition of sequences at simple and double temporal resolution. Sequences are processed to compute myocardial motion by an automatic technique based on the tracking of the harmonic phase of tagged images (the Harmonic Phase Flow, HPF). The results have been compared to manual tracking of myocardial tags. The error in displacement fields for double resolution sequences reduces 17%.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor Alan Murray  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area (up) Expedition Conference  
  Notes IAM Approved no  
  Call Number IAM @ iam @ GGB2008 Serial 1508  
Permanent link to this record
 

 
Author Jaume Garcia; Debora Gil; Joel Barajas; Francesc Carreras; Sandra Pujades; Petia Radeva edit   pdf
openurl 
  Title Characterization of ventricular torsion in healthy subjects using Gabor filters and a variational framework Type Conference Article
  Year 2006 Publication Proc. Computers in Cardiology Abbreviated Journal  
  Volume Issue Pages 877-880  
  Keywords  
  Abstract In this work, we present a fully automated method for tissue deformation estimation in tagged magnetic resonance images (TMRI). Gabor filter banks, tuned independently for each left ventricle level, provide optimally filtered complex images which phase remains constant along the cardiac cycle. This fact can be thought as the brightness constancy condition required by classical optical flow (OF) methods. Pairs of these filtered sequences, together with a variational formulation are used in a second step to obtain dense continuous deformation maps that we call Harmonic Phase Flow. This method has been used to determine reference values of ventricular torsion (VT) in a set of 8 healthy volunteers. The results encourage the use of VT as a useful parameter for ventricular function assessment in clinical routine.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area (up) Expedition Conference  
  Notes IAM;MILAB Approved no  
  Call Number IAM @ iam @ GGB2006a Serial 1509  