|
Records |
Links |
|
Author |
Jaume Garcia; Debora Gil; A.Bajo; M.J.Ledesma-Carbayo; C.SantaMarta |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
![find record details (via OpenURL) openurl](http://refbase.cvc.uab.es/img/xref.gif)
|
|
Title ![sorted by Title field, ascending order (up)](http://refbase.cvc.uab.es/img/sort_asc.gif) |
Influence of the temporal resolution on the quantification of displacement fields in cardiac magnetic resonance tagged images |
Type |
Conference Article |
|
Year |
2008 |
Publication |
Proc. Computers in Cardiology |
Abbreviated Journal |
|
|
|
Volume |
35 |
Issue |
|
Pages |
785-788 |
|
|
Keywords |
|
|
|
Abstract |
It is difficult to acquire tagged cardiac MR images with a high temporal and spatial resolution using clinical MR scanners. However, if such images are used for quantifying scores based on motion, it is essential a resolution as high as possible. This paper explores the influence of the temporal resolution of a tagged series on the quantification of myocardial dynamic parameters. To such purpose we have designed a SPAMM (Spatial Modulation of Magnetization) sequence allowing acquisition of sequences at simple and double temporal resolution. Sequences are processed to compute myocardial motion by an automatic technique based on the tracking of the harmonic phase of tagged images (the Harmonic Phase Flow, HPF). The results have been compared to manual tracking of myocardial tags. The error in displacement fields for double resolution sequences reduces 17%. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
Alan Murray |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GGB2008 |
Serial |
1508 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Petia Radeva |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
![find record details (via OpenURL) openurl](http://refbase.cvc.uab.es/img/xref.gif)
|
|
Title ![sorted by Title field, ascending order (up)](http://refbase.cvc.uab.es/img/sort_asc.gif) |
Inhibition of false landmarks |
Type |
Journal Article |
|
Year |
2006 |
Publication |
Pattern Recognition Letters |
Abbreviated Journal |
PRL |
|
|
Volume |
27 |
Issue |
9 |
Pages |
1022-1030 |
|
|
Keywords |
|
|
|
Abstract |
Corners and junctions are landmarks characterized by the lack of differentiability in the unit tangent to the image level curve. Detectors based on differential operators are not, by their own definition, the best posed as they require a higher degree of differentiability to yield a reliable response. We argue that a corner detector should be based on the degree of continuity of the tangent vector to the image level sets, work on the image domain and need no assumptions on neither the image local structure nor the particular geometry of the corner/junction. An operator measuring the degree of differentiability of the projection matrix on the image gradient fulfills the above requirements. Because using smoothing kernels leads to corner misplacement, we suggest an alternative fake response remover based on the receptive field inhibition of spurious details. The combination of both orientation discontinuity detection and noise inhibition produce our inhibition orientation energy (IOE) landmark locator. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Elsevier Science Inc. |
Place of Publication |
New York, NY, USA |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0167-8655 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GiR2006 |
Serial |
1529 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Petia Radeva |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
|
|
Title ![sorted by Title field, ascending order (up)](http://refbase.cvc.uab.es/img/sort_asc.gif) |
Inhibition of False Landmarks |
Type |
Book Chapter |
|
Year |
2004 |
Publication |
Recent Advances in Artificial Intelligence Research and Development |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
233-244 |
|
|
Keywords |
|
|
|
Abstract |
We argue that a corner detector should be based on the degree of continuity of the tangent vector to the image level sets, work on the image domain and need no assumptions on neither the image local structure nor the particular geometry of the corner/junction. An operator measuring the degree of differentiability of the projection matrix on the image gradient fulfills the above requirements. Its high sensitivity to changes in vector directions makes it suitable for landmark location in real images prone to need smoothing to reduce the impact of noise. Because using smoothing kernels leads to corner misplacement, we suggest an alternative fake response remover based on the receptive field inhibition of spurious details. The combination of both orientation discontinuity detection and noise inhibition produce our Inhibition Orientation Energy (IOE) landmark locator. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
IOS Press |
Place of Publication |
Barcelona (Spain) |
Editor |
al, J.V. et |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GiR2004a |
Serial |
1533 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Antonio Esteban Lansaque; Agnes Borras; Esmitt Ramirez; Carles Sanchez |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
![goto web page (via DOI) doi](http://refbase.cvc.uab.es/img/doi.gif)
|
|
Title ![sorted by Title field, ascending order (up)](http://refbase.cvc.uab.es/img/sort_asc.gif) |
Intraoperative Extraction of Airways Anatomy in VideoBronchoscopy |
Type |
Journal Article |
|
Year |
2020 |
Publication |
IEEE Access |
Abbreviated Journal |
ACCESS |
|
|
Volume |
8 |
Issue |
|
Pages |
159696 - 159704 |
|
|
Keywords |
|
|
|
Abstract |
A main bottleneck in bronchoscopic biopsy sampling is to efficiently reach the lesion navigating across bronchial levels. Any guidance system should be able to localize the scope position during the intervention with minimal costs and alteration of clinical protocols. With the final goal of an affordable image-based guidance, this work presents a novel strategy to extract and codify the anatomical structure of bronchi, as well as, the scope navigation path from videobronchoscopy. Experiments using interventional data show that our method accurately identifies the bronchial structure. Meanwhile, experiments using simulated data verify that the extracted navigation path matches the 3D route. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; 600.139; 600.145 |
Approved |
no |
|
|
Call Number |
Admin @ si @ GEB2020 |
Serial |
3467 |
|
Permanent link to this record |
|
|
|
|
Author |
Mireia Sole; Joan Blanco; Debora Gil; G. Fonseka; Richard Frodsham; Oliver Valero; Francesca Vidal; Zaida Sarrate |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
|
|
Title ![sorted by Title field, ascending order (up)](http://refbase.cvc.uab.es/img/sort_asc.gif) |
Is there a pattern of Chromosome territoriality along mice spermatogenesis? |
Type |
Conference Article |
|
Year |
2017 |
Publication |
3rd Spanish MeioNet Meeting Abstract Book |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
55-56 |
|
|
Keywords |
|
|
|
Abstract |
|
|
|
Address |
Miraflores de la Sierra; Madrid; June 2017 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
MEIONET |
|
|
Notes |
IAM; 600.096; 600.145 |
Approved |
no |
|
|
Call Number |
Admin @ si @ |
Serial |
2958 |
|
Permanent link to this record |
|
|
|
|
Author |
Debora Gil; Petia Radeva; Josefina Mauri |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
|
|
Title ![sorted by Title field, ascending order (up)](http://refbase.cvc.uab.es/img/sort_asc.gif) |
Ivus Segmentation Via a Regularized Curvature Flow |
Type |
Conference Article |
|
Year |
2002 |
Publication |
X Congreso Anual de la Sociedad Española de Ingeniería Biomédica CASEIB 2002 |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
133-136 |
|
|
Keywords |
|
|
|
Abstract |
Cardiac diseases are diagnosed and treated through a study of the morphology and dynamics of cardiac arteries. In- travascular Ultrasound (IVUS) imaging is of high interest to physicians since it provides both information. At the current state-of-the-art in image segmentation, a robust detection of the arterial lumen in IVUS demands manual intervention or ECG-gating. Manual intervention is a tedious and time consuming task that requires experienced observers, meanwhile ECG-gating is an acquisition technique not available in all clinical centers. We introduce a parametric algorithm that detects the arterial luminal border in in vivo sequences. The method consist in smoothing the sequences’ level surfaces under a regularized mean curvature flow that admits non-trivial steady states. The flow is based on a measure of the surface local smoothness that takes into account regularity of the surface curvature. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Saragossa, Espanya |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM;MILAB |
Approved |
no |
|
|
Call Number |
IAM @ iam @ GRM2002 |
Serial |
1536 |
|
Permanent link to this record |
|
|
|
|
Author |
Antoni Gurgui; Debora Gil; Enric Marti |
![goto web page url](http://refbase.cvc.uab.es/img/www.gif)
![find book details (via ISBN) isbn](http://refbase.cvc.uab.es/img/isbn.gif)
|
|
Title ![sorted by Title field, ascending order (up)](http://refbase.cvc.uab.es/img/sort_asc.gif) |
Laplacian Unitary Domain for Texture Morphing |
Type |
Conference Article |
|
Year |
2015 |
Publication |
Proceedings of the 10th International Conference on Computer Vision Theory and Applications VISIGRAPP2015 |
Abbreviated Journal |
|
|
|
Volume |
1 |
Issue |
|
Pages |
693-699 |
|
|
Keywords |
Facial; metamorphosis;LaplacianMorphing |
|
|
Abstract |
Deformation of expressive textures is the gateway to realistic computer synthesis of expressions. By their good mathematical properties and flexible formulation on irregular meshes, most texture mappings rely on solutions to the Laplacian in the cartesian space. In the context of facial expression morphing, this approximation can be seen from the opposite point of view by neglecting the metric. In this paper, we use the properties of the Laplacian in manifolds to present a novel approach to warping expressive facial images in order to generate a morphing between them. |
|
|
Address |
Munich; Germany; February 2015 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
SciTePress |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-989-758-089-5 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
VISAPP |
|
|
Notes |
IAM; 600.075 |
Approved |
no |
|
|
Call Number |
Admin @ si @ GGM2015 |
Serial |
2614 |
|
Permanent link to this record |
|
|
|
|
Author |
Francesc Carreras; Jaume Garcia; Debora Gil; Sandra Pujadas; Chi ho Lion; R.Suarez-Arias; R.Leta; Xavier Alomar; Manuel Ballester; Guillem Pons-Llados |
![goto web page url](http://refbase.cvc.uab.es/img/www.gif)
![find record details (via OpenURL) openurl](http://refbase.cvc.uab.es/img/xref.gif)
|
|
Title ![sorted by Title field, ascending order (up)](http://refbase.cvc.uab.es/img/sort_asc.gif) |
Left ventricular torsion and longitudinal shortening: two fundamental components of myocardial mechanics assessed by tagged cine-MRI in normal subjects |
Type |
Journal Article |
|
Year |
2012 |
Publication |
International Journal of Cardiovascular Imaging |
Abbreviated Journal |
IJCI |
|
|
Volume |
28 |
Issue |
2 |
Pages |
273-284 |
|
|
Keywords |
Magnetic resonance imaging (MRI); Tagging MRI; Cardiac mechanics; Ventricular torsion |
|
|
Abstract |
Cardiac magnetic resonance imaging (Cardiac MRI) has become a gold standard diagnostic technique for the assessment of cardiac mechanics, allowing the non-invasive calculation of left ventric- ular long axis longitudinal shortening (LVLS) and absolute myocardial torsion (AMT) between basal and apical left ventricular slices, a movement directly related to the helicoidal anatomic disposition of the myocardial fibers. The aim of this study is to determine AMT and LVLS behaviour and normal values from a group of healthy subjects. A group of 21 healthy volunteers (15 males) (age: 23–55 y.o., mean:30.7 ± 7.5) were prospectively included in an obser- vational study by Cardiac MRI. Left ventricular rotation (degrees) was calculated by custom-made software (Harmonic Phase Flow) in consecutive LV short axis planes tagged cine-MRI sequences. AMT was determined from the difference between basal and apical planes LV rotations. LVLS (%) was determined from the LV longitudinal and horizontal axis cine-MRI images. All the 21 cases studied were interpretable, although in three cases the value of the LV apical rotation could not be determined. The mean rotation of the basal and apical planes at end-systole were -3.71° ± 0.84° and 6.73° ± 1.69° (n:18) respectively, resulting in a LV mean AMT of 10.48° ± 1.63° (n:18). End-systolic mean LVLS was 19.07 ± 2.71%. Cardiac MRI allows for the calculation of AMT and LVLS, fundamental functional components of the ventricular twist mechanics conditioned, in turn, by the anatomical helical layout of the myocardial fibers. These values provide complementary information about systolic ventricular function in relation to the traditional parameters used in daily practice. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Netherlands |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1569-5794 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
IAM; |
Approved |
no |
|
|
Call Number |
IAM @ iam @ CGG2012 |
Serial |
1496 |
|
Permanent link to this record |
|
|
|
|
Author |
Antoni Gurgui; Debora Gil; Enric Marti; Vicente Grau |
![goto web page (via DOI) doi](http://refbase.cvc.uab.es/img/doi.gif)
|
|
Title ![sorted by Title field, ascending order (up)](http://refbase.cvc.uab.es/img/sort_asc.gif) |
Left-Ventricle Basal Region Constrained Parametric Mapping to Unitary Domain |
Type |
Conference Article |
|
Year |
2016 |
Publication |
7th International Workshop on Statistical Atlases & Computational Modelling of the Heart |
Abbreviated Journal |
|
|
|
Volume |
10124 |
Issue |
|
Pages |
163-171 |
|
|
Keywords |
Laplacian; Constrained maps; Parameterization; Basal ring |
|
|
Abstract |
Due to its complex geometry, the basal ring is often omitted when putting different heart geometries into correspondence. In this paper, we present the first results on a new mapping of the left ventricle basal rings onto a normalized coordinate system using a fold-over free approach to the solution to the Laplacian. To guarantee correspondences between different basal rings, we imposed some internal constrained positions at anatomical landmarks in the normalized coordinate system. To prevent internal fold-overs, constraints are handled by cutting the volume into regions defined by anatomical features and mapping each piece of the volume separately. Initial results presented in this paper indicate that our method is able to handle internal constrains without introducing fold-overs and thus guarantees one-to-one mappings between different basal ring geometries. |
|
|
Address |
Athens; October 2016 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
LNCS |
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
STACOM |
|
|
Notes |
IAM; |
Approved |
no |
|
|
Call Number |
Admin @ si @ GGM2016 |
Serial |
2884 |
|
Permanent link to this record |
|
|
|
|
Author |
Patricia Marquez; Debora Gil; R.Mester; Aura Hernandez-Sabate |
![download PDF file pdf](http://refbase.cvc.uab.es/img/file_PDF.gif)
|
|
Title ![sorted by Title field, ascending order (up)](http://refbase.cvc.uab.es/img/sort_asc.gif) |
Local Analysis of Confidence Measures for Optical Flow Quality Evaluation |
Type |
Conference Article |
|
Year |
2014 |
Publication |
9th International Conference on Computer Vision Theory and Applications |
Abbreviated Journal |
|
|
|
Volume |
3 |
Issue |
|
Pages |
450-457 |
|
|
Keywords |
Optical Flow; Confidence Measure; Performance Evaluation. |
|
|
Abstract |
Optical Flow (OF) techniques facing the complexity of real sequences have been developed in the last years. Even using the most appropriate technique for our specific problem, at some points the output flow might fail to achieve the minimum error required for the system. Confidence measures computed from either input data or OF output should discard those points where OF is not accurate enough for its further use. It follows that evaluating the capabilities of a confidence measure for bounding OF error is as important as the definition
itself. In this paper we analyze different confidence measures and point out their advantages and limitations for their use in real world settings. We also explore the agreement with current tools for their evaluation of confidence measures performance. |
|
|
Address |
Lisboa; January 2014 |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
VISAPP |
|
|
Notes |
IAM; ADAS; 600.044; 600.060; 600.057; 601.145; 600.076; 600.075 |
Approved |
no |
|
|
Call Number |
Admin @ si @ MGM2014 |
Serial |
2432 |
|
Permanent link to this record |